Models 427G and 427RG Installation | 29 |
Side Panels
Side panels for models 427G and 427RG are not attached to the unit. You must securely fasten the panels to the adjacent cabinets and floor.
Panels should be fastened to the floor and walls using
Complete the Installation
ANCHORING
Brackets and screws are provided for mounting the unit to adjoining cabinets and side panels. Each unit has four
For dual installations or installations where you are not attaching to a side wall, you must remove the side- mounting clips before moving the unit into position. After removing the clips, replace the screws into the appliance.
A dual installation heater kit is necessary for anchoring two model 427G, 427RG or integrated units together. The kit is available through your authorized
subzero.com
OPTIONAL 90° DOOR STOP
The door of models 427G and 427RG opens to 105°. A 90° door stop is built into the hinge system for installa- tions where the door opening must be limited.
To engage the door stop, use the blade edge of a stand- ard screwdriver and rotate the cam in the center portion of the hinge. You must make this adjustment to both the bottom and top hinge. Refer to the illustration below.
INSTALLATION CHECKLIST
When you have completed installation of the model 427G or 427RG wine storage unit, refer to page 54 for an instal- lation checklist and page 55 for service information.
90° door stop.