INSTALLER/CONFIGURATION MENU

19)Comfort Alert with Active Protection – Turn this feature ON to enable active protection. This allows the thermostat to identify fault codes sent by the Comfort Alert module when compressor damage is possible and react to those codes by turning the compressor off. Fault codes from the Comfort Alert module will flash on the thermostat. (Refer to Comfort Alert Yellow Alert Codes in Troubleshooting section.) If a Comfort Alert module is not connected, or to disable active protection, turn this feature OFF. If a Comfort Alert module is connected and this feature is turned OFF, the thermostat will still receive and flash the fault codes from the Comfort Alert module, but the active protection will not be enabled to protect the compressor.

20 & 21) Select Filter Replacement Reminder and Set Run Time – Select the “Change Filter” reminder On or OFF. If selected On, press MENU to select the time

period from 25 to 1975 hours in 25 hours increments. In a typical system, 200 hours (default) of run time is approximately 30 days. After the selected time of blower operation, the thermostat will display “Change Filter” as a reminder to change or clean your air filter. When “Change Filter” is displayed, press MENU or RUN SCHED button to clear the display and restart the time to the next filter change.

22)Select Reversing Valve Output – The O/B option is factory set at “O” position. This will accommodate the majority of heat pump applications, which require the

changeover relay to be energized in COOL. If the thermostat you are replacing or the heat pump being installed with this thermostat requires a “B” terminal, to energize the changeover relay in HEAT, the O/B option should be set at “B” position.

OPERATING YOUR THERMOSTAT

Choose the Fan Setting (Auto or On)

Press the FAN button to Auto or On.

Fan Auto is the most commonly selected setting and runs the fan only when the heating or cooling system is on.

Fan On runs the fan continuously for increased air circulation or to allow additional air cleaning.

Choose the System Setting

(Heat, Off, Cool, Auto, Emer)

Press the SYSTEM button to select:

Heat: Thermostat controls only the heating system.

Off: Heating and Cooling systems are off.

Cool: Thermostat controls only the cooling system.

Auto: Auto Changeover is used in areas where both heating and cooling may be required on the same day. AUTO allows the thermostat to automatically select heating or cooling depending on the indoor temperature and the selected heat and cool temperatures. When using AUTO, be sure to set the Cooling temperatures more than 1° Fahrenheit higher than the heating temperature.

Emer: (Heat Pump models) Thermostat controls only backup heating system.

Manual Operation for Non-Programmable Mode

Press the SYSTEM button to select Heat or Cool and use

the or buttons to adjust the temperature to your desired setting. After selecting your desired settings you can also press the SYSTEM button to select AUTO to allow the thermostat to automatically change between Heat and Cool.

IMPORTANT!

Second Stage Time Delay

Your thermostat is designed to determine the optimum time to activate the second stage. Simply raising the temperature in heating or lowering it in cooling will not always force the thermostat to bring the second stage on quickly. There is a time delay from 0-30 minutes depending on the performance of the first stage of the system.

EXAMPLE: For the last 2 hours the thermostat is set on 70° and the room temperature is 70° with the equipment using only the first stage of heat. Since the equipment is keeping the temperature within 1° of setpoint, the thermostat will delay second stage for a longer time if you manually raise the temperature or if the room temperature quickly changes. Once the second stage comes on, it will come on sooner the next time there is a difference between the setpoint and the room temperature. The net effect of the staging program is that when the first stage is capable of making temperature the second stage will delay longer. When the thermostat calculates that first stage cannot make temperature in a reasonable time, the second stage will come on sooner. This built in function automatically optimizes the use of additional stages of heat or cool.

TROUBLESHOOTING

Comfort Alert Codes

The Comfort Alert diagnostics product monitors the air con- ditioning outdoor systems with single phase Copeland Scroll compressors. Abnormal system and electrical conditions are indicated by flashing ALERT codes on the yellow LED on the Comfort Alert module. The flash codes are transmitted to the thermostat by the Comfort Alert Thermostat interface module. The Comfort Alert compatible thermostat displays “Call For Service” that flashes at the same rate as the yellow LED on the Comfort Alert module.

Comfort Alert Yellow Alert Codes

1 Flash

Long run time

2 Flashs

System pressure trip

3 Flashs

Short cycling

4 Flashs

Locked rotor

5 Flashs

Open circuit

6 Flashs

Open start circuit

7 Flashs

Open run circuit

8 Flashs

Welded Contactor

9 Flashs

Low voltage

7

Image 7
Contents Index SpecificationsApplications Save these instructions for future useRemove Old Thermostat InstallationWiring Connections Installing New ThermostatSingle Stage and Multi-Stage Connections Wire Spdt Heat Only Zone Valve WiringThermostat Quick Reference Programming and Configuration ItemsDisplays System Mode Heat, Emer, Auto, Cool, Off Displays Fan Mode On, Auto or Run SchedCool To L Selects Limited Cool Range INSTALLER/CONFIGURATION MenuOptions Heat To L Selects Limited Heat RangeSelect Temperature Display Adjustment 4 LO to 4 HI Operating Your Thermostat TroubleshootingReset Operation Symptom Possible Cause Correction ActionUsuario2925-284el-800para-1 ayuda de Problemas DE SoluciónÍneaL Correctiva Acción Posible Causa SíntomaTermostato SU Usar Cómo Configuración INSTALADOR/DE MenúSistema del configuración la Elija On u Auto ventilador del configuración la ElijaDe encima por más o C 2 F 3 en manualmente aumenta se Palabra la aparece no SiPalabra la aparecerá ambiente El con real temperatura laIndicadas opciones MenúMenu Configuración y programación de Elementos 8 FiguraTermostato DEL Rápida Referencia DE Guía Pantalla la de DescripciónCorrectamente configurarlo Conexiones DE DiagramaGas Viejo termostato el retirar Cómo InstalaciónPilas Nuevo termostato del InstalaciónPágina Índice EspecificacionesAplicaciones 7237A-37 Pieza DE N

37-7237A specifications

The White Rodgers 37-7237A is a sophisticated thermostat designed to bring comfort and efficiency to residential heating and cooling systems. It is known for its reliability, user-friendly interface, and a variety of features that cater to the needs of modern homeowners.

One of the standout features of the 37-7237A is its digital display, which provides clear and precise temperature readings, making it easy to monitor and adjust settings. The thermostat is equipped with a simple, intuitive interface that allows for straightforward navigation through its various functions, ensuring that users can easily customize their heating and cooling preferences.

The 37-7237A supports both heat-only and cool-only systems, providing flexibility for different types of HVAC setups. It is compatible with conventional systems as well as heat pumps, making it a versatile choice for numerous household configurations. Additionally, the thermostat offers programmable capabilities, allowing users to set different temperatures for various times of the day. This feature promotes energy efficiency and helps reduce utility costs, as homeowners can lower their heating or cooling when they are not home.

Technologically, the 37-7237A incorporates advanced features such as adaptive intelligent recovery. This technology learns how long it takes to heat or cool a space to the desired temperature and begins to adjust the system's operation accordingly. As a result, the thermostat ensures that the home maintains optimal comfort without unnecessary energy expenditure.

The 37-7237A also includes a built-in temperature sensor that ensures accurate readings, helping to maintain the desired indoor climate. This consistency allows for a stable and comfortable environment, while also protecting the equipment from potential damage caused by extreme temperature fluctuations.

Another benefit of the White Rodgers 37-7237A is its energy-saving capabilities. By utilizing a programmable schedule, users can avoid heating or cooling their homes when they are not occupied. This feature can lead to significant energy savings over time.

In summary, the White Rodgers 37-7237A offers a combination of user-friendly design, advanced technology, and energy efficiency features that make it an excellent choice for homeowners seeking to enhance their indoor comfort. With its versatile compatibility and smart programming capabilities, it's an investment that pays off in both comfort and cost savings.