Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.Close equipment shutoff valve (see Figure 5).

2.Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter.

3.Check all joints from gas meter to equipment shutoff valve (see Figure 5). Apply noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak.

4.Correct all leaks at once.

Nut

Burner Manifold

Knockout

Plugs

Burner Clamp

Equipment Shutoff Valve

Gas Meter

Burner Pan

(Front)Burner Inlet

Screw Fitting

DUAL-FLAME

Figure 6 - Installing Burner

Installation and Gas Connection

1. Place the burner pan assembly in the center of the fireplace floor. Make sure the front of pan faces forward.

2. Thread the gas supply fitting to the fireplace gas supply pipe. Use thread sealant.

3. Install adapter fitting onto the burner inlet fitting using thread

Figure 5 - Checking Gas Jointssealant on male threads of burner inlet fitting (see Figure 7). Adjust to most convenient position.

4. Install the gas connector tube to the gas supply fitting. Carefully shape tube to attach to adapter fitting. Be careful not to cause kinks in tube.

HEARTH KIT ASSEMBLY AND INSTALLATION

Kit Assembly - Dual-Flame Burner

Gas Connector Tube

1.

Determine which side the gas line will be coming into the fire-

 

place.

2.

Using a hammer and screw driver, remove knockout plug from the

 

side of the pan that corresponds to the gas line (see Figure 6).

Burner Pan Assem- bly (Facing Front of Fireplace)

Adapter Fitting

3.

Unscrew burner inlet fitting from burner manifold.

4.

Place burner manifold in pan with threaded opening facing

 

open knockout plug.

5.

Using thread sealant (resistant to the action of propane/LP gas)

 

on larger end of fitting, screw the burner inlet fitting through

 

hole and into burner manifold (see Figure 6). Tighten using

 

a wrench.

6.

Using burner clamp, screw, and nut provided, assemble clamp

 

to pan (“U” style and triple burners only). This will hold the

 

burner manifold in place.

Figure 7 - Connecting Gas to Appliance

OPTIONAL GA9050A ON/OFF SAFETY VALVE/ PILOT KIT ASSEMBLY

For additional convenience and safety, or for propane/LP conver- sion, an optional ON/OFF safety valve/pilot kit is available. See Accessories, page 15.

WARNING: You must use a ON/OFF safety valve/ pilot kit for propane/LP conversion.

For more information, visit www.desatech.com

115043-01

Image 6
Contents Brentwood What to do if YOU Smell GASTable of Contents Unpacking Safety InformationLocal Codes Product IdentificationVenting Specifications for Installation InstallationFlue Opening Specifications Installing Damper ClampInstallation Items Needed Hearth KIT Assembly and Installation Optional GA9050A ON/OFF Safety VALVE/ Pilot KIT AssemblyNatural Gas Installation Testing Burner for Leaks Adding PAN MaterialOperating Appliance Replacement Parts Service HintsTechnical Service Cleaning MaintenanceTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Troubleshooting Accessories Equipment Shutoff Valve GA5010Parts List and Illustrated Parts Breakdown Owners Registration Form Postage Required 115043-01 115043-01 Warranty Information Keep this Warranty

RGA 2-72 specifications

Desa RGA 2-72 is a notable residential development that epitomizes modern living through the integration of innovative technologies and sustainable features. This project is designed to cater to the diverse needs of families while promoting a sense of community and environmental responsibility.

One of the main features of Desa RGA 2-72 is its focus on eco-friendly living. The development incorporates green building materials and energy-efficient designs that minimize environmental impact. Each unit is equipped with solar panels, enabling residents to harness renewable energy, thus reducing reliance on traditional energy sources and lowering utility bills. This commitment to sustainability extends to rainwater harvesting systems, which help to conserve water and reduce waste.

The architectural design of Desa RGA 2-72 reflects contemporary aesthetics combined with functional layouts. The homes are designed with open-concept floor plans that maximize natural light and create spacious living environments. Large windows and high ceilings enhance the sense of space and openness, providing a comfortable and inviting atmosphere for residents.

Another key characteristic of this development is the incorporation of smart home technologies. Each unit comes equipped with smart thermostats, lighting controls, and security systems that can be easily managed through a mobile app. This automation not only enhances convenience but also contributes to energy savings, as residents can monitor and control their energy usage remotely.

Community amenities are also a significant aspect of Desa RGA 2-72. The development features landscaped green spaces, playgrounds for children, and recreational facilities designed to foster social interaction among residents. Walking and biking paths encourage outdoor activities, promoting a healthy lifestyle while strengthening community bonds.

Accessibility is another advantage of this development. Located near essential services, including schools, shops, and healthcare facilities, residents enjoy the convenience of urban living without sacrificing the tranquility of suburban life.

In conclusion, Desa RGA 2-72 stands out as a model for modern, eco-friendly residential living. With its focus on sustainability, smart technologies, and community-oriented design, it offers an attractive option for families seeking a harmonious blend of comfort, convenience, and environmental responsibility. This development not only meets the demands of contemporary living but also sets a standard for future residential projects.