Desa GL36PNEP, GL36PNP Safety Information, High traffic areas Windy or drafty areas

Page 3

SAFETY INFORMATION

WARNING: This product contains and/or generates chemicals known to the State of California to cause cancer or birth defects or other reproduc- tive harm.

IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, op- erate or service this fireplace. Improper use of this fireplace cancause serious injury or death from burns, fire, explosions, electrical shock and carbon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

This fireplace is a vented product. This fireplace will not produce any gas leakage into your home if properly installed. This fireplace must be properly installed by a qualified service person. If this unit is not properly installed by a qualified service person, gas leakage can occur.

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness or nausea. If you have these signs, the fireplace may not have been installed properly. Get fresh air at once! Have fireplace inspected and serviced by a qualified service person. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol and those at high altitudes.

Propane/LP gas and natural gas are both odorless. An odor-making agent is added to each of these gases. The odor helps you detect a gas leak. How- ever, the odor added to these gases can fade. Gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace.

WARNING: Any change to this fireplace or its controls can be dangerous.

1.This appliance is only for use with the type of gas indicated on the rating plate. This ap- pliance is not convertible for use with other gases.

2.For propane/LP fireplace, do not place propane/ LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors. To prevent performance problems, do not use propane/LP fuel tank of less than 100 lbs. capacity.

3.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighborʼs phone. Follow the gas supplier's instructions

if you cannot reach you gas supplier, call the fire department.

4.Never install the fireplace

in a recreational vehicle

where curtains, furniture, clothing or other flammable objects are less than 42" from the front, top or sides of the fireplace

in high traffic areas

in windy or drafty areas

5.This fireplace reaches high temperatures. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Fireplace will remain hot for a time after shutdown. Allow surfaces to cool before touching.

6.Carefully supervise young children when they are in the room with fireplace.

7.A hearth extension is not required with this appliance. If one is installed, it is for aesthetic purposes only and does not have to meet the standard requirements.

8.Turn fireplace off and let cool before servicing or repairing. Only a qualified service person should install, service or repair this fireplace. Have fireplace inspected annually by a quali- fied service person.

9.You must keep control compartments, burn- ers and circulating air passages clean. More frequent cleaning may be needed due to ex- cessive lint and dust from carpeting, bedding material, etc. Turn off the gas valve and pilot light before cleaning fireplace.

10.Have venting system inspected annually by a qualified service person. If needed, have vent- ing system cleaned or repaired. See Cleaning and Maintenance, page 15.

55175-F

www.desatech.com

3

Image 3
Contents Marblehead For Your SafetyTable of Contents High traffic areas Windy or drafty areas Safety InformationDimensions Introduction Selecting LocationBefore YOU Begin Fireplace Installation ClearancesMantel Clearances Framing Vent Pipe InstallationMillivolt Models GL36PN/PNP Optional Outside AIR KIT Model AK4Electronic Models GL36PNE/PNEPGAS Line HOOK-UP GAS Supply TestingFireplace Facing LOG SET PlacementPilot Assembly Adjustment Burner Flame AdjustmentMantels Optional Glass Door Installing Glass DoorMillivolt Models For Your Safety Read Before Lighting Operating FireplaceLighting Instructions To Turn OFF GAS To Appliance Electronic Models For Your Safety Read Before LightingCleaning Maintenance Technical ServiceSpecifications Millivolt Wiring Diagram Wiring DiagramsTroubleshooting Observed Problem Possible Cause RemedyMillivolt System See Pilot will not stay lit, above Electronic Ignition SystemReplacement Parts and Accessories Remedy and Exclusions Limited 2-YEAR Warranty

GL36PNEP, GL36PNP, GL36PN, GL36PNE specifications

Desa GL36PN, GL36PNP, GL36PNEP, and GL36PNE are advanced gas fireplaces designed to provide warmth, ambiance, and aesthetic appeal to any living space. These models are known for their cutting-edge features and efficient technology, making them ideal for modern homes looking for both comfort and style.

One of the main features of the Desa GL series is its versatile design, allowing it to seamlessly integrate into various interior styles. The clean and elegant lines of the fireplaces make them an attractive focal point in any room, whether traditional or contemporary. The models come with different finishing options, including a range of trims and decorative fronts, allowing homeowners to customize their look according to personal preference and home decor.

Another significant characteristic of these models is their innovative heating technology. The Desa GL series utilizes advanced venting options that enhance heat distribution throughout the space while ensuring optimal safety. With a focus on efficiency, these appliances are designed to heat effectively while consuming minimal gas, helping homeowners save on energy costs. The models are equipped with an electronic ignition system that ensures reliable lighting and consistent performance, even during power outages.

In addition to heating performance, the Desa GL36PN, GL36PNP, GL36PNEP, and GL36PNE prioritize user comfort and convenience. The included remote control allows for easy adjustments to flame height and temperature, enabling homeowners to create their desired atmosphere with just the push of a button. Some models also come with programmable thermostats, further enhancing user experience by allowing automatic temperature regulation throughout the day.

Safety features are paramount in the design of the Desa GL series. Each model is equipped with a safety shut-off system, ensuring peace of mind for users. The glass front is designed to remain cool to the touch, preventing accidental burns, which is especially important for families with children or pets.

Finally, the aesthetic appeal of the Desa GL series is further enhanced by the realistic flame display and high-quality log sets. The lifelike flame appearance creates a captivating ambiance, making the fireplace a centerpiece in any room, perfect for gatherings or cozy nights in.

In conclusion, the Desa GL36PN, GL36PNP, GL36PNEP, and GL36PNE models combine modern aesthetics with advanced features, ensuring both comfort and safety in home heating. With efficient technology and customizable designs, these fireplaces are a perfect addition to any contemporary living space, offering warmth, style, and convenience.