Desa (V)VC36NE, (V)VC36PE installation manual Horizontal Termination Configurations

Page 10

10

VENTING INSTALLATION INSTRUCTIONS Installation Planning (Cont.)

VENTING INSTALLATION INSTRUCTIONS Continued

10.Place fireplace into position and shim with noncombustible material if needed. Nail or screw side flanges to framing to secure unit in place. IMPORTANT: Make sure fireplace is level before securing. If fireplace is not level it will not work properly.

Minimum Pipe

Siding Standoff

1

/4"

Overlap 1

 

 

 

Screws

Direct Vent

 

 

Pipe

 

 

Wall

 

 

Firestop

 

 

Maintain 1"

 

 

 

 

 

Minimum Air

 

 

 

 

 

Space Around

 

 

 

 

 

Outer Pipe When

 

 

 

 

Penetrating a Wall

 

 

High Wind

10

 

/4" x

10

Termination

3

Apply Mastic to

3

/4" Framed

 

 

 

 

 

Opening

 

Outside Edge of

 

 

 

 

 

Standoff

 

 

 

 

 

Exterior Wall

 

 

 

 

 

with Vinyl Siding

Figure 13 - Typical Horizontal Termination Cap Mounting with

Additional Siding Standoff Installed

 

Horizontal Termination Configurations

Figures 14 through 18 show different configurations and alternatives for venting with horizontal termination. Each figure includes a chart with critical minimum and maximum dimensions which MUST be met. IMPORTANT: Remember that a horizontal run of venting must have a 1/4" rise for every 12" of run toward the termination.

WARNING: Never run vent downward as this may cause excessive temperatures which could cause a fire. Operation of improperly installed and maintained venting system could result in serious injury, property damage or loss of life.

GROUND FLOOR INSTALLATION

Recommended Applications:

Installation using cabinet surrounds

Through the wall using round or square termination (up to 12" horizontal pipe)

NOT FOR CORNER INSTALLATION

45° Elbow

Horizontal High

Wind Square

Termination

Adjustable

Pipe 12" Max.

Wall Firestop

Square Termination

Vertical (V) Horizontal (H)

32 3/4"

17" max.

45° Elbow

Wall

 

Exterior Portion of

Firestop

 

Wall Firestop (Round

 

 

 

 

 

Termination Only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Horizontal

Round

Termination

Figure 14 - Horizontal Termination Configuration for Square or Round Termination

www.desatech.com

116235-01C

Image 10
Contents For Your Safety For Your Safety What to do if YOU Smell GASTable of Contents Safety InformationControl Valve Safety Information Product IdentificationLocal Codes BlowerPRE-INSTALLATION Preparation Product FeaturesLocation and Space Requirements 35 3/4 133/4 10 3/8 49 5/8 ClearancesFraming and Finishing 681/2Location of Termination CAP Termination CAP AIR Supply Inlet GAS MeterVenting Installation Instructions Installation PrecautionsMale Female Slots Locking Lugs Installation PlanningHorizontal Termination Installation CenterHorizontal Vent Cap Wood ScrewInterior Wall Surface Firestop Vent Cap Vent PipeHorizontal Termination Configurations 30 max VerticalSnorkel Termination Minimum Venting with Two 90 Elbows Roof Flashing Wall Strap Elbow Ceiling Firestop Installation for Vertical TerminationFlat Ceiling Installation If area above is a room orVertical Termination Configurations Elbow Into inner collar fireplace as shownHigh Altitude Installation Installing Optional Blower Accessory Venting InstallationFireplace Installation Check GAS Type Desa 5/8 Pipe & Vent KitsFireplace Installation Model BKT InstallationBlower Wiring Diagram Installing GAS Piping to Fireplace LocationInstallation Items Needed Pressure Testing Gas Supply Piping System Connecting Fireplace to GAS SupplyChecking GAS Connections REMOVING/REPLACING Glass Door Pressure Testing Fireplace Gas ConnectionsRemoving Louver Panels Cleaning Glass Door Installing Lava Rock and Glowing EmbersRemoving Glass Door Wall Switch Installation Installing Brick Liner Models BL36DASA and BL36DHASAOptional Remote Control Operating Fireplace Wiring DiagramFor Your Safety Read Before Lighting Lighting InstructionsOptional Remote Operating Optional Blower AccessoryTo Turn OFF GAS To Appliance OperationPilot and Burners Cleaning MaintenanceGlass Door LogsTroubleshooting Observed Problem Possible Cause RemedyGas leak. See Warning statement at Technical Service Replacement PartsService Hints Parts Under WarrantySpecifications Illustrated Parts Breakdown Models VC36NE, VVC36NE, VC36PE and VVC36PEParts List KEY Part Number Description QTY2827 19 18 116235-01C KEY Part Number Description Accessories Model BrandDate Purchased Serial Number Industrial Drive Box Bowling Green, KY 116235-01C Model Serial No Date Purchased Warranty InformationIndustrial Drive P.O. Box

(V)VC36NE, (V)VC36PE specifications

Desa (V)VC36NE and (V)VC36PE are advanced probe technology designed for precise diagnostic and measurement applications in various industries, including manufacturing, automotive, and healthcare. These models are representative of Desa's commitment to innovation and excellence in engineering, providing users with essential features and cutting-edge technologies.

One of the main features of the (V)VC36NE model is its enhanced resolution, allowing for accurate data collection even in the most challenging environments. This high-resolution capability makes it ideal for detailed inspections and quality control, ensuring that manufacturers can meet stringent performance standards. Meanwhile, the (V)VC36PE model is equipped with a user-friendly interface that simplifies data interpretation, making it accessible to operators with varying levels of technical expertise.

Both models utilize advanced sensing technologies, including capacitive and resistive sensing, enabling them to capture real-time data with exceptional precision. This technology effectively reduces the margin for error, which is critical in applications where even minor discrepancies can lead to significant consequences. Furthermore, the integration of wireless communication in these models allows for seamless data transmission, enhancing connectivity and facilitating remote monitoring capabilities.

Another characteristic that sets Desa's (V)VC36NE and (V)VC36PE apart is their durability. Constructed with high-grade materials, they are designed to withstand harsh operating conditions, ensuring longevity and reliability. This robustness means that users can depend on these probes for consistent performance over time, reducing downtime and maintenance costs.

The versatility of the (V)VC36NE and (V)VC36PE models is another notable advantage. They are compatible with a broad range of accessories and can be easily integrated into existing systems, making them suitable for various applications across different sectors. Whether for industrial automation or healthcare diagnostics, these models provide excellent adaptability.

In conclusion, Desa’s (V)VC36NE and (V)VC36PE probes exemplify the brand's focus on delivering high-performance, reliable, and user-centric diagnostic solutions. Their advanced features, including high resolution, durable construction, and versatile compatibility, make them invaluable tools in modern industries, enhancing productivity and efficiency while ensuring high-quality outcomes.