Venting Installation
instructions
Continued
Note: Install restrictor into inner collar of fireplace as shown.
Vertical Venting
V = 40' max.
Note: Install restrictor into inner collar of fireplace as shown.
45° Elbow | 45° Elbow |
Venting with Two 90° Elbows
Vertical (V1) | Horizontal (H) |
5' min. | 6' max. |
6' min. | 12' max. |
7' min. | 18' max. |
8' min. | 20' max. |
Note: Vertical (V1) + Vertical (V2) = 40' max.
Figure 23 - Vertical Venting
Configuration Using Two 90° Elbows
(Vertical Round High Wind Termination
Shown)
Figure 24 - Vertical Venting
Configuration With No Horizontal Run
(Vertical Round High Wind Termination
Shown)
High Altitude Installation
Your
Fireplaces for High Altitude (models ending in
When installing a
When installing this fireplace at an elevation above 4500 feet (in Canada), check with local authorities.
www.desatech.com | 17 |