Location of Termination Cap
D
E 
 V
B L ![]()
  | C  | 
  | 
  | Fixed  | V  | 
  | Closed  | |
  | 
  | |
F  | Openable  | 
  | 
V  | 
  | |
  | B  | 
  | 
B
Openable
B
Fixed
Closed
H
V
B
I
V J XG
AM
NN
  | G  | 
  | V  | 
  | G  | 
V K X  | V  | 
V TERMINATION CAP | X AIR SUPPLY INLET | G  | GAS METER | 
A
RESTRICTED AREA 
 (TERMINATION PROHIBITED)
A= clearance above grade, veranda, porch, deck, or balcony [*12 inches (30.5mc) minimum]
B= clearance to window or door that may be opened
[12 inches (30.5cm) minimum]
C = clearance to permanently closed window [minimum 12 inches (30.5cm) recommended to prevent condensation on window]
D = vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 24 inches (61cm) from the 
E= clearance to unventilated soffit [12 inches (30.5cm) minimum]
F= clearance to outside corner (see below)
G= clearance to inside corner (see below)
H= *not to be installed above a meter/regulator assembly within
36 inches (91.4cm) horizontally from the 
I= clearance to service regulator vent outlet [*72 inches (182.9cm) minimum]
J= clearance to 
K= clearance to a mechanical air supply inlet [*72 inches (182.9cm) minimum]
L= † clearance above paved 
M= clearance under veranda, porch, deck [*12 inches (30.5cm) minimum ‡]
N= clearance above a roof shall extend a minimum of 24 inches (61cm) above the highest point when it passes through the roof surface and any other obstruction within a horizontal distance of 18 inches (45.7cm)
† vent shall not terminate directly above a 
‡only permitted if veranda, porch, deck or balconey is fully open on a minimum of 2 sides beneath the floor* * as specified in CAN/CSA B149 (.1 or .2) Installation Codes (1991) for Canada and U.S.A.
Note: Local codes or regulations may require different clearances
Termination Clearances for Buildings with Combustible and Noncombustible Exteriors
Inside Corner
A
V
Outside Corner  | Recessed Location  | 
  | 
  | D  | 
  | 
  | C  | C  | 
A = 6" (15.2cm)  | 
  | E  | 
  | 
  | |
V  | V  | 
  | 
B  | B = 6" (15.2cm)  | 
  | 
Balcony with No Side Wall
G  | 
V  | 
G = 12" (30.5cm) minimum clearance
Balcony with Perpendicular Side Wall
H ![]()
V
![]()
 J
Combustible &
Noncombustible
H = 24" (61cm)
J = 20" (50.8cm)
C = Maximum depth of 48" (121.9cm) for recessed location
D = Minimum width for back wall of recessed location - Combustible - 38" (965mm) Noncombustible - 24" (61cm)
E = Clearance from corner in recessed location- Combustible - 6" (15.2cm) Noncombustible - 2" (5.1cm)
Figure 7 - Minimum Clearances for Termination Cap
www.desatech.com116200-01F