Desa VV42EPB(1), VV42ENB(1), V42EN-A, V42EP-A installation manual Clearances, Framing and Finishing

Page 5

PRE-INSTALLATION PREPARATION

Clearances

Framing and Finishing

5

PRE-INSTALLATION

PREPARATION

Continued

CLEARANCES

Minimum clearances to combustibles for the fireplace are as follows:

Back, and sides

0"/mm

Perpendicular walls

6" (152mm)

Floor

0"/mm

Ceiling to louver opening

42" (1067mm)

Front

36" (914mm)

Top

0"/mm

Vent

(See venting instructions for

 

specific venting clearances.)

Combustible material with a maximum thickness of 5/8" may be flush with the top front of fireplace .

21 5/ "

B 8

41A5/8"

E

13D 1/2"

C

1

 

58

/2"

16 3/4"

F48"

48G 1/4

"

Nailing Tabs

81H 1/2"

NOTICE: This fireplace is intended for use as supple- mental heat. Use this fireplace along with your pri- mary heating system. Do not install this fireplace as your primary heat source. If you have a central heat- ing system, you may run system’s circulating blower while using fireplace. This will help circulate the heat throughout the house. In the event of a power outage, you can use this fireplace as a heat source.

FRAMING AND FINISHING

Figure 4 shows typical framing of this fireplace. Figure 5 shows framing for corner installation. All minimum clearances must be met.

For available accessories for this fireplace, see Accessories on page

37.If you are using a separate combustible mantel piece, refer to Figure 6 for proper installation height. You can install noncombus- tible mantels at any height above the fireplace. Note: Noncombus- tible mantels may discolor!

40 1/8"

48 1/4"

25 5/8"

Figure 5 - Framing Clearances for Corner Installation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

Wall

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Top of Louver Opening

 

 

 

 

 

 

 

Ref.

Mantel Depth

Ref.

Mantel from Top

 

 

 

 

 

 

 

 

 

 

 

 

of Louver Opening

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

14" (356mm)

 

A

 

 

 

16" (406mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

12" (305mm)

 

B

 

 

 

14" (356mm)

 

 

 

3

10" (254mm)

 

C

 

 

 

12" (305mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

8" (203mm)

 

D

 

 

 

10" (254mm)

 

 

 

5

6" (152mm)

 

E

 

 

 

8" (203mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

4" (101mm)

 

F

 

 

 

6" (152mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

2" (51mm)

 

G

 

 

 

4" (101mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 6 - Clearances for Combustible Mantels

Figure 4 - Framing Clearances for Installation Against an Exterior

Wall

For morevisit www..com

111907-01D

Image 5
Contents For Your Safety What to do if YOU Smell GAS OWNER’S Operation Installation ManualFor Your Safety Safety Information Table of ContentsLocal Codes Product IdentificationLocation and Space Requirements Product FeaturesPRE-INSTALLATION Preparation Framing and Finishing ClearancesBalcony with Perpendicular Side Wall Location of Termination CAPInstallation Precautions Venting Installation InstructionsHorizontal Termination Installation Installation PlanningInstalling Horizontal Vent Cap Noncombustible Exterior Ground Floor Installation Horizontal Termination ConfigurationsCorner Installation Venting with Two 90 Elbows Flat Ceiling Installation Installation for Vertical TerminationVertical Termination Configurations Desa 5/8 Pipe & Vent Kits High Altitude InstallationInstalling Optional Blower Accessory Fireplace InstallationModel BK Installation Check GAS TypeBlower Model BKT Model BKT InstallationInstallation Items Needed Installing GAS Piping to Fireplace LocationBlower Wiring Diagram Nections, Connecting Fireplace to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Gas Connections REMOVING/REPLACING Glass Door Cleaning Glass DoorRemoving Louver Panels Removing Glass DoorInstalling LOGS, Lava Rock and Glowing Embers Installing Optional Brick Liner Models BL42DASA, BL42DHASAInstalling Log No and Log No Optional Remote Control Wiring DiagramWall Switch Installation Operating Fireplace For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To AppliancePilot Assembly Operating Optional Blower AccessoryInspecting Burners Burner Flame PatternGlass Door Cleaning MaintenancePilot and Burners LogsObserved Problem Possible Cause Remedy TroubleshootingGas leak. See Warning statement at Models Illustrated Parts BreakdownVV42EPSB1 VV42EPHB1 Description QTY Parts ListBurner Assembly for Models KEY Part Number Description QTY V42EP-A, VV42EPSB1, and VV42EPHB1Service Hints Replacement PartsTechnical Service SpecificationsOwners Registration Form Postage Required Accessories Warranty Information

V42EN-A, VV42EPB(1), V42EP-A, VV42ENB(1) specifications

Desa VV42ENB(1), VV42EPB(1), V42EN-A, and V42EP-A are innovative products designed to enhance residential heating and hot water solutions. These units are a part of a modern era in energy-efficient home appliances that aim to provide comfort while minimizing environmental impact.

The VV42ENB(1) and VV42EPB(1) models are particularly notable for their energy efficiency. They incorporate advanced technology that significantly reduces energy consumption compared to traditional heating systems. The VV42ENB(1), which operates using natural gas, is designed for environments where gas is readily available, while the VV42EPB(1) utilizes propane, making it ideal for areas without natural gas supply. The flexibility in fuel sources provides homeowners with more options tailored to their specific needs.

Both models are equipped with a high-efficiency burner that optimizes fuel combustion, ensuring efficient heat transfer and reduced greenhouse gas emissions. The integrated smart thermostat feature allows users to program their heating schedules, which not only enhances comfort but also contributes to energy conservation by reducing wastage when the home is unoccupied.

Transitioning to the V42EN-A and V42EP-A models, these units are designed to cater to different heating requirements. Featuring advanced electronic ignition systems, they provide reliable operation with minimal maintenance requirements. The aesthetic design of these models allows them to blend seamlessly into any home decor while the durable materials ensure longevity and resilience under various conditions.

Furthermore, the V42EN-A and V42EP-A models come with enhanced safety features, including auto shut-off systems and flame failure devices that protect against unintended incidents. Homeowners can trust that these units will operate safely and efficiently.

In summary, the Desa VV42ENB(1), VV42EPB(1), V42EN-A, and V42EP-A are remarkable advancements in home heating technology. Their focus on energy efficiency, user-friendly features, and safety makes them a perfect choice for modern households looking to enhance comfort while maintaining a commitment to sustainability. With options for different fuels and advanced functionalities, they stand as a testament to innovation in the heating industry. These models promise not only to keep homes warm but also to do so in an environmentally responsible manner.