Page 23
C-clockwise

OPERATING FIREPLACE (THERMOSTAT-CONTROLLED MODELS)

For Your Safety Read Before Lighting

Lighting Instructions

23

OPERATING FIREPLACE

THERMOSTAT-CONTROLLED MODELS

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing prop- erty damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire de- partment.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service techni- cian or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING

INSTRUCTIONS

WARNING: You must operate this fireplace with the screen in place. Make sure fireplace screen is installed before running fireplace.

NOTICE: During initial operation of new fireplace, burning logs will give off a paper-burning smell. Open window to vent smell. Operate fireplace on HI position to burn off odor. This will only last a few hours.

1.STOP! Read the safety information above.

2.Make sure equipment shutoff valve is fully open.

3. Turn control knob clockwise Clockwise to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information above. If you don’t smell gas, go to the next step.

5. Turn control knob counterclockwise to the PI- LOT position. Press in control knob for five (5) seconds (see Figure 45).

Note: You may be running this fireplace for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will al- low air to bleed from the gas system.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, press and release ignitor but- ton. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, refer to Troubleshooting, pages 29 through 31. Also, contact a qualified service per- son or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure on page 25.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. This fire- place has a safety interlock system. Wait one (1) minute for system to reset before lighting pilot again.

8.Turn control knob counterclockwise to desired heating level. The burner should light. Set control knob to any heat level between HI and LO.

CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.

Ignitor

Control Knob

Button

 

Figure 45 - Control Knob In The OFF Position

Thermocouple

 

 

Ignitor Electrode

Ignitor

Thermocouple

Pilot

Pilot

Electrode

Burner

Burner

 

Figure 46 - Natural Gas Pilot Figure 47 -Propane/LP Gas Pilot

For morevisit www..com

107032-01F

Image 23
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Table of ContentsVent-Free Compact Classic Hearth Fireplace Product IdentificationUnpacking Optional Remote Control AccessoriesProduct Features Local CodesAssembling Fireplace AssemblyDetermining FRESH-AIR Flow for Fireplace Location AIR for Combustion and VentilationProviding Adequate Ventilation Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors InstallationMinimum Clearance to Combustible Materials Installation ItemsCheck GAS Type Fireplace ClearancesRough Opening for Installing in Wall BUILT-IN Fireplace InstallationMantel Clearances for Built-In Installation Optional Mantel InstallationAssembling Brass Trim Brass trim shipped with mantel Removing Upper Louver Assembly and Branch SupportInstalling Blower Bracket Assembly Installing Blower AccessoryExtension Cord For Built-In InstallationRemoving Upper Louver Assembly Removing Valve Cover Shield Installing Blower AssemblyValve Cover Shield Switch PlateScrew Attaching Wood Base to Solid Floor Connecting to GAS SupplyInstallation Items Needed Connecting Equipment Shutoff Valve to Heater ControlChecking GAS Connections Pressure Testing gas Supply Piping systemInstalling Receiver Optional Wireless HAND-HELD Remote Control AccessoriesPressure Testing Fireplace Gas Connections Optional Wall Mounted Thermostat GWMT1 Installing 9-Volt Battery in Hand-Held Remote Control UnitBack View of Thermostat Base Installing LOG SET and ScreenLighting Instructions Operating FireplaceThermostat Control Operation Manual Lighting ProcedureREMOTE-READY Models For Your Safety Read Before Lighting To Turn OFF GAS To AppliancePropane/LPGasPilot Natural Gas Pilot Ghrcta Series Operation Optional Remote OperationGWMT1 Wall Mounted Thermostat Optional Thermostat Control OperationBurner Flame Pattern GWMS2 Wall Mounted Switch OptionalInspecting Burners Pilot Flame PatternCabinet Cleaning MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole LOG SETObserved Problem Possible Cause Remedy TroubleshootingRemedy Observed Problem Possible CauseGas leak. See Warning statement When Gas Pressure Is Too Low SpecificationsService Hints Technical ServiceRemote-Ready Models Only Replacement Parts Wiring DiagramParts Under Warranty Parts not Under WarrantyTHERMOSTAT-CONTROLLED Models VMH10TPB, VMH10TNB Illustrated Parts BreakdownTHERMOSTAT-CONTROLLED Models Parts ListEFS26PR, EFS26NR REMOTE-READY ModelsParts List Accessories Receiver and HAND-HELD Remote Control KIT Ghrc Cleaning KIT GCKWALL-MOUNT Thermostat Switch GWMT1 WALL-MOUNT ON/OFF Switch GWMS2For . .com Owners Registration Form Postage Required 107032-01F Limited Warranty VENT-FREE Compact Classic Hearth Fireplace Warranty Information

VMH10TNB, VMH26NRA, EFS26PR, VMH26PRA specifications

Desa VMH26PRA, EFS26PR, VMH10TNB, and VMH26NRA are notable models in the versatile and efficient heater category that cater to diverse heating needs. Each unit incorporates advanced technologies and features designed to provide reliable warmth while ensuring user convenience.

The Desa VMH26PRA is known for its robust design and impressive performance. Featuring a powerful output, it efficiently warms up spaces making it ideal for larger areas. The model is equipped with a digital thermostat that allows for precise temperature control, providing users the ability to set and maintain their desired warmth effortlessly. Additionally, its safety features, including an automatic shut-off mechanism, ensure peace of mind during operation.

EFS26PR stands out for its energy efficiency and eco-friendly attributes. This model utilizes innovative heating technology that minimizes energy consumption while maximizing output. An integrated fan promotes enhanced air circulation, ensuring that heat disperses evenly throughout the room. The compact design and portability mean it can be easily moved from one location to another, making it a perfect choice for both residential and commercial spaces.

VMH10TNB is notable for its unique combination of performance and aesthetic appeal. This model features a sleek contemporary design that can complement various interior styles. With adjustable heat settings and a user-friendly control panel, this unit aims to provide customized comfort. Moreover, the advanced infrared heating technology utilized in VMH10TNB distributes warmth without compromising air quality, making it a wise choice for those with respiratory sensitivities.

Lastly, the VMH26NRA model is amplified by its high-capacity heating potential. Perfect for colder climates, it boasts a powerful heat output that ensures rapid warmth in a short time. The model is engineered with user-friendly touch controls and a programmable timer that enhances convenience. Safety remains a priority with this heater, which includes a tip-over switch and overheat protection, ensuring secure operation at all times.

In summary, the Desa VMH26PRA, EFS26PR, VMH10TNB, and VMH26NRA all bring distinct features and technologies designed to cater to various heating requirements. Whether looking for advanced safety features, energy efficiency, or stylish design, these models present excellent options for effective heating solutions.