Desa VMH26NRA, EFS26PR, VMH26PRA, VMH10TNB installation manual Gas leak. See Warning statement

Page 31

TROUBLESHOOTING

31

TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating fireplace where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Remote does not function (Remote-Ready Models Only)

1.Battery is not install. Battery power is low

1.Replace 9-volt batteries in receiver and remote control

Fireplace produces a clicking/ticking noise just after burners are lit or shut off

1.Metal expanding while heating or con- tracting while cooling

1.This is common with most fireplaces. If noise is excessive, contact qualified ser- vice person

Fireplace produces unwanted odors

1.

Fireplace burning vapors from paint,

 

 

hair spray, glues, cleaners, chemicals,

 

 

new carpet, etc. (See IMPORTANT

 

 

statement above)

 

2.

Low fuel supply (propane/LP only)

 

3.

Gas leak. See Warning statement

 

 

at top of page

1.Open window to ventilate room. Stop us- ing odor causing products while fire- place is running

2.Refill supply tank (propane/LP only)

3.Locate and correct all leaks (see Check- ing Gas Connections, pages 19 and 20)

Fireplace shuts off in use (ODS operates)

1.

Not enough fresh air is available

1.

Open window and/or door for ventilation

 

2.

Low line pressure

2.

Contact local natural or propane/LP gas

 

 

 

 

company

 

3.

ODS/pilot is partially clogged

3.

Clean ODS/pilot (see Cleaning and

 

 

 

 

Maintenance, page 28)

 

 

 

 

 

Gas odor even when control knob is in OFF

1.

Gas leak. See Warning statement

1.

Locate and correct all leaks (see Check-

position

 

at top of page

 

ing Gas Connections, pages 19 and 20)

 

2.

Control valve defective

2.

Replace control valve

 

 

 

 

 

Gas odor during combustion

1.

Foreign matter between control valve

 

 

and burner

 

2.

Gas leak. See Warning statement

 

 

at top of page

1.Take apart gas tubing and remove for- eign matter

2.Locate and correct all leaks (see Check- ing Gas Connections, pages 19 and 20)

For morevisit www..com

107032-01F

Image 31
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Table of ContentsVent-Free Compact Classic Hearth Fireplace Product IdentificationUnpacking Optional Remote Control AccessoriesProduct Features Local CodesAssembling Fireplace AssemblyProviding Adequate Ventilation AIR for Combustion and VentilationDetermining FRESH-AIR Flow for Fireplace Location Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors InstallationMinimum Clearance to Combustible Materials Installation ItemsCheck GAS Type Fireplace ClearancesRough Opening for Installing in Wall BUILT-IN Fireplace InstallationMantel Clearances for Built-In Installation Optional Mantel InstallationAssembling Brass Trim Brass trim shipped with mantel Removing Upper Louver Assembly and Branch SupportInstalling Blower Bracket Assembly Installing Blower AccessoryRemoving Upper Louver Assembly For Built-In InstallationExtension Cord Removing Valve Cover Shield Installing Blower AssemblyValve Cover Shield Switch PlateScrew Attaching Wood Base to Solid Floor Connecting to GAS SupplyInstallation Items Needed Connecting Equipment Shutoff Valve to Heater ControlChecking GAS Connections Pressure Testing gas Supply Piping systemPressure Testing Fireplace Gas Connections Optional Wireless HAND-HELD Remote Control AccessoriesInstalling Receiver Optional Wall Mounted Thermostat GWMT1 Installing 9-Volt Battery in Hand-Held Remote Control UnitBack View of Thermostat Base Installing LOG SET and ScreenLighting Instructions Operating FireplaceThermostat Control Operation Manual Lighting ProcedureREMOTE-READY Models For Your Safety Read Before Lighting To Turn OFF GAS To AppliancePropane/LPGasPilot Natural Gas Pilot Ghrcta Series Operation Optional Remote OperationGWMT1 Wall Mounted Thermostat Optional Thermostat Control OperationBurner Flame Pattern GWMS2 Wall Mounted Switch OptionalInspecting Burners Pilot Flame PatternCabinet Cleaning MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole LOG SETObserved Problem Possible Cause Remedy TroubleshootingRemedy Observed Problem Possible CauseGas leak. See Warning statement When Gas Pressure Is Too Low SpecificationsService Hints Technical ServiceRemote-Ready Models Only Replacement Parts Wiring DiagramParts Under Warranty Parts not Under WarrantyTHERMOSTAT-CONTROLLED Models VMH10TPB, VMH10TNB Illustrated Parts BreakdownTHERMOSTAT-CONTROLLED Models Parts ListEFS26PR, EFS26NR REMOTE-READY ModelsParts List Accessories Receiver and HAND-HELD Remote Control KIT Ghrc Cleaning KIT GCKWALL-MOUNT Thermostat Switch GWMT1 WALL-MOUNT ON/OFF Switch GWMS2For . .com Owners Registration Form Postage Required 107032-01F Limited Warranty VENT-FREE Compact Classic Hearth Fireplace Warranty Information

VMH10TNB, VMH26NRA, EFS26PR, VMH26PRA specifications

Desa VMH26PRA, EFS26PR, VMH10TNB, and VMH26NRA are notable models in the versatile and efficient heater category that cater to diverse heating needs. Each unit incorporates advanced technologies and features designed to provide reliable warmth while ensuring user convenience.

The Desa VMH26PRA is known for its robust design and impressive performance. Featuring a powerful output, it efficiently warms up spaces making it ideal for larger areas. The model is equipped with a digital thermostat that allows for precise temperature control, providing users the ability to set and maintain their desired warmth effortlessly. Additionally, its safety features, including an automatic shut-off mechanism, ensure peace of mind during operation.

EFS26PR stands out for its energy efficiency and eco-friendly attributes. This model utilizes innovative heating technology that minimizes energy consumption while maximizing output. An integrated fan promotes enhanced air circulation, ensuring that heat disperses evenly throughout the room. The compact design and portability mean it can be easily moved from one location to another, making it a perfect choice for both residential and commercial spaces.

VMH10TNB is notable for its unique combination of performance and aesthetic appeal. This model features a sleek contemporary design that can complement various interior styles. With adjustable heat settings and a user-friendly control panel, this unit aims to provide customized comfort. Moreover, the advanced infrared heating technology utilized in VMH10TNB distributes warmth without compromising air quality, making it a wise choice for those with respiratory sensitivities.

Lastly, the VMH26NRA model is amplified by its high-capacity heating potential. Perfect for colder climates, it boasts a powerful heat output that ensures rapid warmth in a short time. The model is engineered with user-friendly touch controls and a programmable timer that enhances convenience. Safety remains a priority with this heater, which includes a tip-over switch and overheat protection, ensuring secure operation at all times.

In summary, the Desa VMH26PRA, EFS26PR, VMH10TNB, and VMH26NRA all bring distinct features and technologies designed to cater to various heating requirements. Whether looking for advanced safety features, energy efficiency, or stylish design, these models present excellent options for effective heating solutions.