INSTALLING

Continued

Minimum Non Combustible Material Clearances

If Using Mantel

You must have non combustible material(s) above the fireplace opening. Non combustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have non combustible material behind it. Non combustible material must extend at least 8 inches up (for all models). If non combustible material is less than 12", you must install the fireplace hood accessory (24" model only). Even if non combustible material is more than 12", you may need the hood accessory to deflect heat away from your mantel shelf. See chart below and Figures 6 and 7 for minimum clearances.

IMPORTANT: If you cannot meet these minimum clearances, you must operate heater with chimney flue damper open. Go to Installing Damper Clamp Accessory for Vented Operation, page 14.

Non-Combustible

Requirements for

Material Distance (A)

Safe Installation

 

 

12" or more

Non combustible material OK.

Between 8" and 12"

24" Model: Install fireplace hood accessory (GA6050

 

or GA6052, see Accessories, page 29).

 

18" Model: Non combustible material OK.

Less than 8"

Non combustible material must be extended to at

 

least 8". See Between 8" and 12", above. If you

 

cannot extend material, you must operate heater with

 

flue damper open.

 

 

Mantel Clearances

If you meet minimum clearance between mantel shelf and top of fireplace opening, a hood is not required (see Figure 6).

 

10"

Mantel Shelf

 

 

 

 

 

 

 

 

 

Underside of

 

8"

 

 

 

 

 

 

 

 

 

 

 

Mantel Shelf

 

 

 

 

 

 

 

 

 

6"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 1/2"

 

 

 

 

 

All minimum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

distances are

Minimum Non-

 

 

(A)

 

 

 

 

 

in inches

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Combustible

 

 

 

 

 

 

 

Log Set

 

 

 

 

 

 

 

 

Material

 

 

 

 

 

 

 

 

 

 

12"

20"

241/2"

271/2"

30"

 

24" Models

 

 

 

 

 

 

 

8"

14"

163/4"

181/2"

20"

 

18" Model

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Top of Fireplace

Opening

Minimum Non-

Distances to

Combustible

Underside of

Material Height

Mantel

Figure 6 - Minimum Mantel Clearances Without Using Hood

If above minimum clearances are not met, you must have a hood. Follow minimum clearances shown in Figure 7 on page 13 when using hood.

102783

Image 12
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GAS24 Variable Manually-Controlled Models Contents Safety Information With this heater Local Codes Unpacking Flame-MaxStandard Split ComboProduct Features AIR for Combustion and Ventilation Safety DeviceOperation Piezo Ignition SystemProviding Adequate Ventilation Unusually Tight ConstructionUnconfined Space Confined SpaceAIR for VentilationDetermining AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installing Vented configuration. Check your state or local codesCheck GAS Type Flue damper closedMinimum Fireplace Clearance To Combustible Materials LOG Sizing RequirementsMinimum Wall and Ceiling Clearances see Figure Minimum Non Combustible Material Clearances If Using Mantel Installing Installing Damper Clamp Accessory for Vented Operation Attaching Damper ClampInstalling Installation Items NeededConnecting to GAS Supply Installation Items NeededExternal Regulator With Vent Pointing Down Pressure Testing Gas Supply Piping System Checking GAS ConnectionsPressure Testing Heater Gas Connections Manual Shutoff ValveInstalling Logs Add lava rock around base of heaterHeater Operating Heater Inspecting Burners Pilot Flame PatternCleaning and Maintenance Trouble Shooting Turn off heater and let cool before cleaningODS/PILOT and Burner LogsSee Cleaning Trouble Shooting Cleaning and MainteTROUBLE- Shooting Statement at topTechnical Service Service HintsVariable Manually Controlled Accessories PartsIllustrated Parts Breakdown Parts List Parts Available not ShownWarranty Information Keep this Warranty

102783-01B specifications

Desa 102783-01B is a cutting-edge device that combines innovative technology with user-centric design, making it a significant addition to the rapidly evolving tech landscape. This model is particularly notable for its high-performance capabilities and robust features, aiming to meet the diverse needs of modern users.

One of the standout characteristics of the Desa 102783-01B is its powerful processing unit. Equipped with a next-generation multi-core processor, this device ensures smooth operation and responsiveness, allowing users to run demanding applications and multitask effortlessly. The high RAM capacity further enhances performance, enabling quick access to frequently used files and applications, thus improving workflow efficiency.

In addition to its processing capabilities, the Desa 102783-01B incorporates advanced connectivity options. With support for the latest Wi-Fi standards, users can benefit from faster internet speeds and more reliable connections. The device also boasts Bluetooth 5.0 technology, allowing seamless pairing with other devices and accessories, which enhances versatility and convenience in various settings.

The display of the Desa 102783-01B is another highlight. It features a high-resolution screen with vibrant colors and sharp contrast, providing an immersive viewing experience for both work and entertainment. This aspect makes the device particularly appealing to professionals who require precision in visual tasks, such as graphic design and video editing.

Moreover, the Desa 102783-01B places a strong emphasis on security and privacy. It includes advanced biometric authentication options, such as fingerprint recognition, ensuring that user data remains protected. This aspect is crucial in today's digital landscape, where data breaches and unauthorized access are significant concerns.

The design of the Desa 102783-01B also deserves mention. It presents a sleek and modern aesthetic, making it not only functional but visually appealing. The ergonomic design enhances comfort during extended use, catering to users who spend long hours working on their devices.

In summary, the Desa 102783-01B emerges as a robust, feature-rich device that excels in performance, connectivity, and security. Its combination of advanced technology and thoughtful design caters to the needs of both professionals and casual users alike, positioning it as a commendable choice in today’s competitive tech market. As it continues to garner attention, the Desa 102783-01B is set to redefine user experiences across various domains.