Desa CGF265PVA, CGF280PT installation manual To Turn OFF GAS to Appliance

Page 23

OPERATING

8.

Turn control knob counterclockwise

to desired heating level. The

 

FIREPLACE

 

burners should light. Set control knob to any heat level between HI and LO.

 

 

 

Thermostat-

 

CAUTION

Controlled Model

 

 

 

Do not try to adjust heating levels by using the manual shutoff valve.

Continued

 

 

 

 

 

TO TURN OFF GAS TO APPLIANCE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shutting Off Fireplace

 

 

 

 

 

 

 

 

 

Turn control knob clockwise

to the OFF position.

 

Shutting Off Burners Only (pilot stays lit)

 

Turn control knob clockwise

to the PILOT position.

 

 

 

 

THERMOSTAT CONTROL OPERATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

You can set the thermostat control knob to any comfort level between HI and LO.

 

The thermostat will gradually modulate the heat output and flame height from higher

 

to lower settings, or pilot, in order to maintain the comfort level you select. The ideal

 

comfort setting will vary by household depending upon the amount of space to be

 

heated, the output of the central heating system, etc.

 

Note: Selecting the HI setting will cause the burner to remain on without modulating

 

down in most

cases.

 

 

 

 

 

 

 

 

 

MANUAL LIGHTING PROCEDURE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. Follow steps 1 through 5 under Lighting Instructions, page 22.

 

2. Depress control knob and light pilot with match.

 

3. Keep control knob pressed in for 30 seconds after lighting pilot. After 30

 

 

seconds, release control knob. Now follow step 8, above.

OPERATING

 

 

 

 

 

 

FOR YOUR SAFETY READ BEFORE LIGHTING

 

 

 

 

 

 

 

 

 

FIREPLACE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARNING

 

 

 

Variable Manually

 

 

 

 

WARNING ICONG 001

 

 

 

If you do not follow these instructions exactly, a fire or explosion

 

 

Controlled Model

 

 

 

 

may result causing property damage, personal injury or loss of life.

 

 

CGF265PVA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A. This appliance has a pilot which must be lighted by hand. When lighting the pilot,

 

 

follow these instructions exactly.

 

 

 

 

 

 

 

 

 

B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell

 

 

next to the floor because some gas is heavier than air and will settle on the floor.

 

 

WHAT TO DO IF YOU SMELL GAS

 

 

 

• Do not try to light any appliance.

 

 

 

• Do not touch any electric switch; do not use any phone in your building.

 

 

 

• Immediately call your gas supplier from a neighbor’s phone. Follow the gas

 

 

 

supplier’s instructions.

 

 

 

 

 

 

 

 

 

 

 

• If you cannot reach your gas supplier, call the fire department.

 

C. Use only your hand to push in or turn the gas control knob. Never use tools. If the

 

 

knob will not push in or turn by hand, don’t try to repair it, call a qualified service

 

 

technician or gas supplier. Force or attempted repair may result in a fire or

 

 

explosion.

 

 

 

 

 

 

 

 

 

D. Do not use this appliance if any part has been under water. Immediately call a

 

 

qualified service technician to inspect the appliance and to replace any part of the

 

 

control system and any gas control which has been under water.

 

 

 

 

 

 

 

Continued 23

102665

Image 23
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation Manual CGF265PVA CGF280PTContents Safety Information Safety Information Product Identification Product FeaturesLocal Codes UnpackingUnconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space Determining AIR Flow for Fireplace LocationVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallingAssembling Brass Trim Assembling and Attaching Brass TrimMinimum Wall and Ceiling Clearances see Figure Installation ClearancesConventional Fireplace Installation Location of Nailing Flanges Installing Cabinet Mantel BUILT-IN Fireplace InstallationRough Opening for Installing in Corner Mantel Clearances for Built-In Installation Installing GAS Piping to Fireplace LocationExternal Regulator With Vent Pointing Down Installation Items Needed Connecting Fireplace to GAS SupplyAttaching Flexible Gas Lines Together Checking GAS ConnectionsManual Shutoff Valve Pressure Testing Fireplace Gas ConnectionsInstalling Front Log Installing LogsFireplace Installing WarningOperating Lighting Instructions Operating FireplaceTo Turn OFF GAS to Appliance Variable Manually Controlled Model Variable Manual Control Operation Front Burner Flame Pattern Inspecting BurnersPilot Flame Pattern Logs Trouble ShootingODS/PILOT and Burners TROUBLE- Shooting Cleaning and MainteTrouble Maintenance,Observed Possible Remedy Problem Cause Centrals ServiceTechnical PartsIllustrated Parts Breakdown Log Base Assembly Variable Manually Controlled Models Parts ListThermostat Controlled Models Log Base Assembly Thermostat Controlled Models Fireplace CGF280PT CGF265PVA Accessories 102665 Keep this Warranty Warranty Information

CGF265PVA, CGF280PT specifications

Desa CGF280PT and CGF265PVA are advanced gas-powered heating appliances known for their efficiency and innovative features. Ideal for both residential and commercial spaces, these products demonstrate a sophisticated balance of power, performance, and user-friendly design.

The CGF280PT model boasts a robust output of 28,000 BTUs, making it suitable for larger areas that require significant heating capacity. Its high-efficiency system is designed to maximize heat distribution while minimizing energy consumption, allowing users to maintain a comfortable environment without incurring excessive utility costs. Built with a focus on reliable performance, it employs a direct venting system, ensuring optimal combustion and safe, clean operation.

On the other hand, the CGF265PVA model offers a slightly smaller output of 26,500 BTUs and incorporates advanced technology to enhance user experience. One of its standout features is the programmable thermostat, which enables users to set specific temperature preferences. This feature not only enhances comfort but also contributes to energy savings by allowing the system to operate only when necessary.

Both models utilize innovative ceramic technology for their burners. This design not only boosts efficiency by facilitating quicker heat production but also ensures a more even heat distribution within the space. The appliances come equipped with a sleek design that fits seamlessly into modern interiors, featuring a choice of finishes that enhance any decor.

Additionally, the Desa CGF series is engineered with safety in mind. They incorporate high-quality safety measures, including flame sensors and automatic shut-off features, which provide peace of mind during operation. The igniting systems are designed for ease of use, often featuring electronic ignition that eliminates the hassle of manual lighting.

In summary, the Desa CGF280PT and CGF265PVA stand out in the market for their combination of power, efficiency, and cutting-edge technology. Whether for a cozy living room or a larger commercial setting, these heating solutions offer not just warmth, but also energy-efficient operation, ensuring users enjoy both comfort and value. As versatile heating options, they remain a popular choice among homeowners and business owners alike, reflecting modern needs in heating appliances.