Desa CGF265PVA, CGF280PT installation manual Trouble, Maintenance

Page 29

TROUBLE-

 

OBSERVED

POSSIBLE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PROBLEM

CAUSE

REMEDY

 

SHOOTING

 

 

 

 

 

 

 

 

 

 

 

 

 

One or both burners do

1.

Burner orifice(s)

1.

Clean burner(s) (see

 

Continued

 

not light after ODS/

 

clogged

 

Cleaning and Mainte-

 

 

 

pilot is lit

 

 

 

nance, page 27) or replace

 

 

 

 

2.

Burner orifice(s)

 

burner orifice(s)

 

 

 

 

2.

Replace burner orifice(s)

 

 

 

 

 

diameter is too small

 

 

 

 

 

 

 

 

 

 

3.

Inlet gas pressure is

3.

Contact local propane/LP

 

 

 

 

 

too low

 

gas company

 

 

 

 

4.

Mislocated crossover

4.

Contact qualified service

 

 

 

 

 

tube

 

person

 

 

 

 

 

 

 

 

 

 

 

 

Delayed ignition of

1. Manifold pressure is

1.

Contact local propane/LP

 

 

 

one or both burners

 

too low

 

gas company

 

 

 

 

2.

Burner orifice(s)

2.

Clean burner(s) (see

 

 

 

 

 

clogged

 

Cleaning and Mainte-

 

 

 

 

 

 

 

nance, page 27) or replace

 

 

 

 

3.

Mislocated crossover

 

burner orifice(s)

 

 

 

 

3.

Contact qualified service

 

 

 

 

 

tube

 

person

 

 

 

 

 

 

 

 

 

 

 

 

 

Burner backfiring

1.

Burner orifice is

1.

Clean burner (see Clean-

 

 

 

during combustion

 

clogged or damaged

 

ing and Maintenance, page

 

 

 

 

 

 

 

27) or replace burner

 

 

 

 

2.

Damaged burner

 

orifice

 

 

 

 

2.

Replace damaged burner

 

 

 

 

3.

Gas regulator defective

3.

Replace gas regulator

 

 

 

 

 

 

 

 

 

 

 

 

Yellow flame in front

1. Not enough air

1.

Check burner(s) for dirt

 

 

 

burner during burner

 

 

 

and debris. If found, clean

 

 

 

combustion

 

 

 

burner(s) (see Cleaning and

 

 

 

 

2.

Gas regulator defective

 

Maintenance, page 27)

 

 

 

 

2.

Replace gas regulator

 

 

 

 

 

 

 

 

 

 

 

 

Slight smoke or odor

1. Residues from manu-

1.

Problem will stop after a

 

 

 

during initial operation

 

facturing processes

 

few hours of operation

 

 

 

 

 

and logs curing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fireplace produces a

1. Turning control knob

1.

Turn control knob to LO

 

 

 

whistling noise when

 

to HI position when

 

position and let warm up

 

 

 

burners are lit

 

burners are cold

 

for a minute

 

 

 

 

2.

Air in gas line

2.

Operate burners until air is

 

 

 

 

 

 

 

removed from line. Have

 

 

 

 

 

 

 

gas line checked by local

 

 

 

 

3.

Air passageways on

 

propane/LP gas company

 

 

 

 

3.

Observe minimum

 

 

 

 

 

fireplace blocked

 

installation clearances

 

 

 

 

4.

Dirty or partially

 

(see page 11)

 

 

 

 

4.

Clean burners (see

 

 

 

 

 

clogged burner

 

Cleaning and Mainte-

 

 

 

 

 

orifice(s)

 

nance, page 27) or replace

 

 

 

 

 

 

 

burner orifice(s)

 

 

 

 

 

 

 

 

 

 

 

 

 

Moisture/condensation

1.

Not enough combus-

1.

Refer to Air for Combus-

 

 

 

noticed on windows

 

tion/ventilation air

 

tion and Ventilation

 

 

 

 

 

 

 

requirements (page 6)

 

 

 

 

 

 

 

Continued

 

 

 

 

 

 

 

 

 

 

 

29

 

 

 

 

 

 

 

 

 

 

 

 

 

102665

Image 29
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation Manual CGF265PVA CGF280PTContents Safety Information Safety Information Product Identification Local Codes FeaturesUnpacking ProductProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Determining AIR Flow for Fireplace LocationVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallingAssembling Brass Trim Assembling and Attaching Brass TrimMinimum Wall and Ceiling Clearances see Figure Installation ClearancesConventional Fireplace Installation Location of Nailing Flanges Installing Cabinet Mantel BUILT-IN Fireplace InstallationRough Opening for Installing in Corner Mantel Clearances for Built-In Installation Installing GAS Piping to Fireplace LocationExternal Regulator With Vent Pointing Down Installation Items Needed Connecting Fireplace to GAS SupplyAttaching Flexible Gas Lines Together Checking GAS ConnectionsManual Shutoff Valve Pressure Testing Fireplace Gas ConnectionsInstalling Front Log Installing LogsFireplace Installing WarningOperating Lighting Instructions Operating FireplaceTo Turn OFF GAS to Appliance Variable Manually Controlled Model Variable Manual Control Operation Front Burner Flame Pattern Inspecting BurnersPilot Flame Pattern Logs Trouble ShootingODS/PILOT and Burners TROUBLE- Shooting Cleaning and MainteTrouble Maintenance,Observed Possible Remedy Problem Cause Technical ServiceParts CentralsIllustrated Parts Breakdown Log Base Assembly Variable Manually Controlled Models Parts ListThermostat Controlled Models Log Base Assembly Thermostat Controlled Models Fireplace CGF280PT CGF265PVA Accessories 102665 Keep this Warranty Warranty Information

CGF265PVA, CGF280PT specifications

Desa CGF280PT and CGF265PVA are advanced gas-powered heating appliances known for their efficiency and innovative features. Ideal for both residential and commercial spaces, these products demonstrate a sophisticated balance of power, performance, and user-friendly design.

The CGF280PT model boasts a robust output of 28,000 BTUs, making it suitable for larger areas that require significant heating capacity. Its high-efficiency system is designed to maximize heat distribution while minimizing energy consumption, allowing users to maintain a comfortable environment without incurring excessive utility costs. Built with a focus on reliable performance, it employs a direct venting system, ensuring optimal combustion and safe, clean operation.

On the other hand, the CGF265PVA model offers a slightly smaller output of 26,500 BTUs and incorporates advanced technology to enhance user experience. One of its standout features is the programmable thermostat, which enables users to set specific temperature preferences. This feature not only enhances comfort but also contributes to energy savings by allowing the system to operate only when necessary.

Both models utilize innovative ceramic technology for their burners. This design not only boosts efficiency by facilitating quicker heat production but also ensures a more even heat distribution within the space. The appliances come equipped with a sleek design that fits seamlessly into modern interiors, featuring a choice of finishes that enhance any decor.

Additionally, the Desa CGF series is engineered with safety in mind. They incorporate high-quality safety measures, including flame sensors and automatic shut-off features, which provide peace of mind during operation. The igniting systems are designed for ease of use, often featuring electronic ignition that eliminates the hassle of manual lighting.

In summary, the Desa CGF280PT and CGF265PVA stand out in the market for their combination of power, efficiency, and cutting-edge technology. Whether for a cozy living room or a larger commercial setting, these heating solutions offer not just warmth, but also energy-efficient operation, ensuring users enjoy both comfort and value. As versatile heating options, they remain a popular choice among homeowners and business owners alike, reflecting modern needs in heating appliances.