Desa LFP33PR To Turn OFF GAS To Appliance, Optional Remote Operation, Optional Blower Operation

Page 17

OWNER’S MANUAL

OPERATING

FIREPLACE

Continued

WARNING: Make sure the selector switch is in the OFF po- sition when you are away from home for long periods of time. Heater will come on automati- cally with selector switch in the ON position.

Pilot Burner

Ignitor

 

Electrode

Figure 38- Pilot

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise to the OFF position.

2a. Set selector switch in the OFF position.

2b. If Using Hand-Held Remote: Set selector switch in the OFF position to keep from draining the battery.

Shutting Off Burners Only (pilot stays lit)

You may shut off the burners and keep the pilot lit by doing one of the following:

OPTIONAL REMOTE

OPERATION

Note: The receiver and hand held remote control must be purchased separately (see Accessories, pages 24 and 25). Follow instructionsincludedwiththeremotecontrol.

Thermostat Control Operation

The thermostat control setting on the remote control unit can be set to any comfort level between HI and LO. The burners will turn on and off automati- cally to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.

NOTICE: You must light the pilot before using the hand-held re- mote control unit. See Lighting Instructions on page 16.

After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Adjust flame adjustment knob anywhere between HI and LO. Slide the selector switch to the REMOTE posi- tion. Note: The burners may light if hand- held remote ON button was on when selector switch was last turned off. You can now turn the burners on and off with the hand-held remote control unit. Follow instructions supplied with the remote con- trol for additional features.

IMPORTANT: Do not leave the selector switch in the REMOTE position when the pilot is not lit. This will drain the battery.

IMPORTANT: Be sure to press the ON/ OFF buttons on the hand-held remote control unit for up to 3 seconds to assure proper operation.

IMPORTANT: The thermostat is built into the hand-held remote. The remote should be kept several feet from the fire- place and should be pointed towards the fireplace. If placed too close to the fire- place, the remote will sense the room is too hot and turn the fireplace off.

OPTIONAL BLOWER

OPERATION

Locate the blower switch by opening lower louver on fireplace. Blower switch is lo- cated at lower left inside louver door.

Thisthermostat-controlledblowerhasthree settings: ON, OFF, and AUTO. In the ON position, the blower will operate constantly. In the OFF position, the blower will not operate. In the AUTO position, the blower will start when the thermostat senses a sufficient increase in firebox temperature.

Note: Your gas logs and thermostat blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blower will continue to run. The blower will shut off after the firebox temperature decreases.

Note: It is safe to operate fireplace with blowerturnedoff.However,theblowerhelps distribute heated air from the fireplace.

Turn control knob clockwise to the PILOT position.

Use remote control manual OFF button.

Set selector switch in the OFF position.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 6 under Light- ing Instructions, page 16.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 9, column 3, page 16.

Flame Adjustment Knob

 

IH

 

P

 

 

F

IL

 

 

 

O

 

 

F

 

T

 

 

O

 

 

 

 

 

 

 

 

 

O

 

 

 

 

N

ON

 

 

 

 

LO

 

 

 

OFF

REMOTE

Control Knob in

On Position Selector Switch in Remote

Position(Optional Remote Control)

Figure 39 - Setting the Selector Switch, Control Knob, and Flame Adjustment Knob for Remote Operation

Continued

104888

17

Image 17
Contents What to do if YOU Smell GAS Unvented VENT-FREE PROPANE/LP GAS FireplaceLFP33PR Unvented PROPANE/LP GAS Fireplace Safety InformationIdentification ProductLocal Codes UnpackingAIR for Combustion and Ventilation Product FeaturesDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Optional GA3750 Blower Accessory InstallationCheck GAS Type Electrical HookupMinimum Wall and Ceiling Clearances see Figure Installation ClearancesConventional Fireplace Installation Location of Nailing Flanges BUILT-IN Fireplace InstallationInstallation Items Needed Installing GAS Piping to Fireplace LocationMantel Clearances for Built-In Installation Flare Union Manual Shutoff Valve Connecting Fireplace to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Gas Connections Installing Screen Installing LogsInstalling Batteries for RM4 Optional Wireless HAND- Held Remote Control Accessory RM4Installing Remote Receiver Unit Installing Batteries in ReceiverInstalling Battery in Receiver Installing Batteries for Ghrc and Ghrct SeriesInstalling Battery in Hand-Held Remote Control Unit Ghrct SeriesLighting Instructions For Your Safety Read Before LightingOperating Fireplace To Turn OFF GAS To Appliance Manual Lighting ProcedureOptional Remote Operation Optional Blower OperationInspecting Burners Cleaning and MaintenanceObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement Service Hints Wiring DiagramSpecifications Technical ServiceParts Under Warranty Replacement PartsParts not Under Warranty Parts CentralCorner Mantel AccessoriesGMC11F Series Walnut Finished Hardwood Veneer GMC13F Series Medium Stained Oak VeneerManual Shutoff Valve Blower AccessoriesDuplex Outlet KIT GA3650T T/Stat Blower for t/stat fireplaces onlyRemote Ready Model LFP33PR Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListFireplace LFP33PR Parts List Warranty Information

LFP33PR specifications

Desa LFP33PR is a notable model within the LFP series, renowned for its advanced features and superior technology. Designed primarily for both residential and commercial applications, the LFP33PR combines efficiency with user-friendly functionality.

One of the standout features of the Desa LFP33PR is its robust energy performance. It is equipped with an advanced heating element that maximizes energy output while minimizing consumption. This energy-efficient design not only reduces utility costs but also aligns with contemporary sustainability goals, making it an environmentally friendly choice for users.

In terms of safety, the Desa LFP33PR incorporates multiple safety mechanisms. These include an automatic shut-off feature that activates when overheating is detected. Additionally, it comes with a built-in flame sensor and a robust housing design that prevents any risk of accidental burns. This focus on safety ensures peace of mind for users, whether in a family home, office environment, or industrial setting.

The LFP33PR also boasts a compact and portable design, making it easy to move from room to room or to different areas within a facility. This portability does not compromise its durability; the unit is constructed with high-quality materials designed to withstand regular use.

Furthermore, the technology integrated into the Desa LFP33PR elevates user experience significantly. It features an intuitive control panel that allows for easy temperature adjustments and timer settings. Users can also benefit from remote control functionality, enabling them to regulate the heating system from a distance.

The aesthetic design of the LFP33PR is another appealing characteristic. Its sleek exterior is available in various colors and can blend seamlessly with different interior styles. This attention to aesthetic detail not only enhances functionality but also ensures that the device adds an element of style to any space.

Maintenance of the Desa LFP33PR is straightforward, with features that allow easy access for cleaning and servicing. The design also minimizes dust accumulation, ensuring optimal performance over time.

In summary, the Desa LFP33PR is a state-of-the-art heating solution, characterized by its efficiency, safety, portability, user-friendly technology, and appealing aesthetics. Its thoughtful design and advanced features make it an excellent choice for those seeking both comfort and reliability in their heating appliances.