Desa MDVFST installation manual General Venting, Mantel Clearances, Framing

Page 4

®

MDVFST DIRECT-VENT GAS FIREPLACE

PRE-INSTALLATION PREPARATION

Continued

MANTEL CLEARANCES

Woodwork, such as wood trims, mantels, and other combustible materials projecting no more than 1 1/2 inches (3.8cm) shall not be placed within 7 inches (17.8cm) from the opening of the unit. Combustible material above and projecting more than 1 1/2 inches (3.8cm) from the appliance’s face must not

"

 

 

5/8

 

 

(600mm)

 

 

39 3/4"

23

 

 

(1010mm)

Min.

43 (1098mm)/4"

Vertical Height

Depends on

Installation

90o Elbow

45o

Elbow

263/8"

(670mm)

Refer to Pages 9 through 12 for Horizontal and Vertical Installation Details

be placed less than 15 inches (38.1cm) from the louver opening (see Figure 5).

Figure 6 - Rough Opening for Installing See Thru Fireplace

Horizontal

Length Depends

on Installation

Combustible

Drywall (Gypsum

Board, Sheetrock, Etc.)

Material May

 

 

Be Used

 

 

Safe Zone for

 

12"

 

 

 

Projection of

 

(305mm)

Combustible

 

Min.

 

 

 

 

Material

21"

4"

 

2 x 4

(533mm)

 

Spacer

Min.

(102mm)

 

15"

Min.

 

 

 

 

 

(381mm)

 

1 1/2" (38mm)

Min.

 

Min.

2" (51mm)

Dia. Hole

(51mm)2"

1" (25mm)

Dia. Hole

(25mm)1"

3"

(76mm)

3" (76mm)

Figure 9 - Vent Opening Height

GENERAL VENTING

Note: Terminations are not designed for installation prior to transportation.

These models are approved for use with both flex and rigid Vanguard vent components as well as Simpson Dura-Vent 6 5/8" direct-vent pipe components and terminations.

Your fireplace is approved to be vented either through the side wall, or vertically using the

7" (178mm)

 

Min.

UNIT

 

Top of Louver

 

Opening

 

Figure 5 - Mantel Clearances

FRAMING

Once the final location has been determined, observing height clearances for vent termi- nation, you may construct framing using dimensions shown in Figure 6, depending on your installation.

If the appliance is to be installed directly on carpeting, tile (other than ceramic), or any combustible material other than wood floor- ing, the appliance must be installed on a metal or wood panel extending the full width and depth of the appliance. There are three holes on each side of the bottom of the unit where screws can be used to secure the unit to the floor.

Figure 7 - Hole Locations For Gas Line and Electric Wires

10"

(254mm) Square Min.

Height

Depends On

Installation

Figure 8 - Rough Opening for Installing Exterior Vent Terminal

following guidelines:

Only use Vanguard or Simpson Dura- Vent GS venting components or kits spe- cifically approved for this fireplace.

Minimum clearance between vent pipes and combustible materials is 1" (25 mm), except where stated otherwise.

Combustible material may be flush with the top front of fireplace with a maxi- mum thickness of 3/4".

Do not recess venting terminals into a wall or siding.

Install horizontal venting with a 1/4" rise for every 12" of run toward the termination.

You may paint the vent terminal with 450°F (232°C) heat-resistant paint to co- ordinate with the exterior finish.

There must not be any obstruction such as bushes, garden sheds, fences, decks, or utility buildings within 24" from the front of the termination cap.

Do not locate termination cap where exces- sive snow or ice build up may occur. Be sure to clear vent termination area after snow falls to prevent accidental blockage of venting system. When using snow blowers, do not direct snow towards vent termination area.

4

106442

Image 4
Contents Check Local Codes Prior to Installation OWNER’S Operation and Installation ManualWhat to do if YOU Smell GAS Introduction Glossary TermsBefore YOU Begin Selecting Location PRE-INSTALLATION PreparationClearances Mantel Clearances General VentingFraming Location of Vent Termination Balcony with Perpendicular Side WallVenting Installation Installation PrecautionsInstallation Planning Installing Vent System in a ChaseInstallation for Horizontal Termination Snorkel TerminationAttach vent pipe assembly to the fire Horizontal Termination Configurations Mdvgfk Kit ShownFlat Ceiling Installation Installation for Vertical TerminationCathedral Ceiling Installation Vertical Termination Configurations Venting with One 90 ElbowVertical Venting High Altitude Installation Parts Lists for Venting Kits and ComponentsSimpson DURA-VENT Vanguard Rigid VentingBlower Assembly Wiring DiagramWall Switch Installation Blower Speed ControlWireless HAND-HELD Remote Control Ghrc Series Installation Electrical Hookup for Blower AccessoryInstalling Receiver GAS Line Hookup Incoming 1/2 Gas Line Permitted by Local CodesGAS Supply Testing Installing LOG SETMaintenance Instructions Pilot Assembly AdjustmentBurner Flame Adjustment Operating GuidelinesOperating Guidelines and Maintenance Instructions For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsWiring Diagram To Turn OFF GAS To ApplianceRemote Operation Lighting InstructionsInstallation PreparationAdjusting AIR Shutter Installation InstructionsFor Conversion Natural to PROPANE/LP Troubleshooting Observed Problem Possible Cause RemedyAfter pilot lights, keep control knob Glass soots Flame impingement on logs Service Hints Technical ServiceReplacement Parts AccessoriesRefractory Pieces Pilot AssemblyGAS Control Valve Warranty Information

MDVFST specifications

Desa MDVFST, an innovative platform designed for multi-dimensional visualization and feature selection, is revolutionizing data analytics in various industries. The core objective of Desa MDVFST is to simplify the process of extracting meaningful insights from complex datasets, enabling analysts and decision-makers to make informed choices swiftly and effectively.

One of the standout features of Desa MDVFST is its ability to handle multi-dimensional data with ease. It employs advanced algorithms to visualize relationships between various data points, allowing users to discern patterns that might be obscured in traditional data analysis methods. This multi-dimensional approach contributes significantly to enhanced data comprehension, leading to more accurate predictions and strategic decisions.

Desa MDVFST is built on a robust technology stack that includes machine learning and artificial intelligence. These technologies are integrated into the platform to automate feature selection, a process critical in identifying the most relevant variables that impact performance. By leveraging machine learning algorithms, Desa MDVFST minimizes human error and enhances efficiency, leading to faster project completion times without sacrificing quality.

Another remarkable characteristic of Desa MDVFST is its user-friendly interface, designed for professionals across various technical backgrounds. This democratization of data analysis ensures that stakeholders from different sectors can utilize the platform without extensive training. The interface allows users to manipulate datasets interactively, providing real-time insights and visualizations that facilitate better decision-making.

Moreover, Desa MDVFST emphasizes scalability, ensuring that businesses can adapt the platform to varying data sizes and complexities. Whether a small enterprise or a large corporation, users can tailor the platform to meet their specific needs, making it a versatile solution for a wide range of applications, from marketing analytics to financial forecasting.

In addition, Desa MDVFST incorporates cloud technology, enhancing accessibility and collaboration among team members. Users can access the platform from any location, ensuring that teams can work together seamlessly, regardless of geographical boundaries.

In conclusion, Desa MDVFST is an advanced tool set to transform the landscape of data analytics with its multi-dimensional visualization capabilities, machine learning-driven feature selection, user-friendly interface, scalability, and cloud accessibility. As businesses increasingly rely on data-driven strategies, Desa MDVFST emerges as a vital resource in achieving actionable insights and a competitive edge in the marketplace.