Desa VGL450N, VGL450P installation manual Introduction, Selecting Location, Before YOU Begin

Page 3

OWNER’S MANUAL

INTRODUCTION

Model VGL450 series is a radiant heat deco- rative gas appliance that uses a millivolt gas control valve and a pilot ignition system.

This appliance requires a 4" B-1 type vent- ing system.

4" B-1 type vent NOT supplied by DESA. Check with your "B" vent instructions for installation guidelines.

WARNING: This gas appli- ance must not be connected to a chimney flue servicing a solid fuel burning appliance.

Model VGL450N uses NATURAL GAS ONLY.

Model VGL450P uses PROPANE GAS ONLY.

If you have any doubts as to which gas your particular unit is approved and tested for, please check the AGA/CGA rating plate located behind the access panel (Figure 1, page 2).

BEFORE YOU BEGIN

Before beginning the installation of your appliance, read these instructions through completely.

This DESA appliance and its approved com- ponents are safe when installed according to this installation manual and are operated as recommended by DESA. Unless you use DESA approved components tested for this appliance, YOU MAY CAUSE A FIRE

HAZARD!

The DESA warranty will be voided by, and DESA disclaims any responsibility for the following actions :

A)Modification of the appliance or any of the components manufactured by DESA unless otherwise permitted in writing by DESA.

B)Use of any component part not ap- proved by DESA in combination with this DESA appliance.

C)Installation and/or operation in a man- ner other than instructed in this manual.

D)The burning of anything other than the type of gas approved for use in this gas appliance.

This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/ NFPA 70 or the CSA C22.1 CANADIAN ELECTRICAL CODE for Canada.

The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code ANSI Z223.1 or with the current CAN/CGA-B149[.1 OR .2] Installation Codes for Canada.

This appliance complies with ANS Z21.50- 1998 and CAN/CGA 2.22-M98 Standard as a VENTED DECORATIVE GAS APPLI- ANCE and is tested and listed by the Ameri- can Gas Association and Canadian Gas Association.

CAUTION: Installation and re- pair should be done by a quali- fied service person. The appli- ance should be inspected before use, and at least annually by a qualified service person. More fre- quent cleaning may be required due to excessive lint from carpet- ing, bedding material, pet hair, etc. It is imperative that the con- trol compartments, burners and circulating air passageways of the appliance be kept clean.

NOTICE: This appliance is not intended to be used as a primary source of heat.

SELECTING

LOCATION

To determine the safest and most efficient location for your appliance, you must take into consideration the following guidelines:

1.The location must allow for proper clearances (see Clearances, page 4 ).

2.Consider a location where heat output would not be affected by drafts, air con- ditioning ducts, windows or doors.

3.A location that avoids the cutting of joists or roof rafters will make installa- tion easier. Figure 3 shows a plan view of a few common locations.

Flush installations are recommended where living space is limited or at a pre- mium, and since the space required to en- close the appliance would be located be- yond an outside wall, this would also reduce the cutting of joists, roof rafters and such. Check local codes for any restrictions.

Projected installations can extend any distance into the room. A projection may be ideal for a new addition on an existing, finished wall.

Corner installations make use of space that may not normally be used and provides a wider and more efficient range for radiant heat transference.

Internal wall installations provide a dis- creet option for room separation and can also be ideal as an addition to an existing wall.

Also, in selecting a location, the following precautions must be observed:

1.Do not connect this appliance to a chimney system used for a solid fuel burning fireplace.

2.Install in an area providing ventilation and adequate combustion air.

3.Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

4.NEVER obstruct the front opening of the appliance or the flow of combus- tion and ventilation air. Keep control compartments accessible.

5.Do not locate in the vicinity where gasoline or other flammable liquids may be stored. The appliance area must be kept clear and free from these com- bustible materials.

CORNER

INTERNAL WALLINSTALLATION

INSTALLATION

FLUSH

FULLINSTALLATION PROJECTION

INSTALLATION

Figure 3 - Possible Locations for Installing Appliance

105704

3

Image 3
Contents For Your Safety VGL450N Natural and VGL450P PROPANE/LPWhat to do if YOU Smell GAS Vented Type Decorative Appliance Introduction Selecting LocationBefore YOU Begin Framing PRE-INSTALLATION PreparationClearances Mantel ClearancesAttaching Fireplace to Wall Studs Venting InstallationInstalling Receiver InstallationWall Switch Installation Wiring DiagramGAS Supply Testing Installing 9-Volt Battery in Hand- Held Remote Control UnitGAS Ratings Is OFF GAS Line HOOK-UPFor Your Safety Read Before Lighting Operating FireplaceLighting Instructions To Turn OFF GAS To Appliance Pilot Assembly AdjustmentBurner Flame Adjustment Operating Guidelines and Maintenance InstructionsParts Under Warranty Wiring Diagram Service HintsTechnical Service Replacement PartsObserved Problem Possible Cause Remedy TroubleshootingGas leak. See Warning statement at Type Vent Pipe Accessories and Replacement PartsPilot Assembly BI-FOLD Glass Doors105704 Limited Warranty Vent Fireplace Warranty Information

VGL450P, VGL450N specifications

Desa VGL450N and VGL450P are two advanced heating solutions designed to provide efficient and effective warmth for various residential and commercial settings. Both models are engineered with modern technology to ensure optimal performance and user convenience.

The VGL450N is a natural gas heater that harnesses the power of natural gas to deliver a steady and reliable heat source. On the other hand, the VGL450P operates on propane, offering flexibility for users who prefer or require propane as their heating fuel. Both units boast a sleek design that fits seamlessly into any environment, making them suitable for installation in living rooms, garages, workshops, and more.

One of the standout features of the VGL450 series is its high efficiency. With an impressive efficiency rating, these heaters effectively convert fuel into heat, minimizing waste and reducing energy costs. This aspect not only benefits users financially but also plays a role in promoting environmental sustainability. Integrated safety features are also a hallmark of the VGL450 models, ensuring peace of mind through mechanisms like automatic shut-off and flame monitoring systems.

In terms of operation, the heaters are designed for simplicity. Both models come equipped with easy-to-use controls, allowing for quick adjustments to temperature settings. Users can enjoy personalized comfort with the capabilities of adjusting the heat output efficiently based on their specific needs. Additionally, these heaters operate quietly, ensuring an unobtrusive experience, allowing users to enjoy warmth without disruptive noise.

The VGL450 series also emphasizes durability and reliability. Constructed with high-quality materials, the heaters are built to withstand the rigors of daily use while providing consistent performance throughout their lifespan. Their user-friendly design facilitates easy maintenance, with accessible components that allow for straightforward cleaning and servicing.

In conclusion, the Desa VGL450N and VGL450P are exceptional heating solutions that combine efficiency, safety, and ease of use. By integrating advanced technologies and sustainable practices, these heaters stand out in today’s market, making them an excellent investment for anyone seeking a reliable heating source for their space. Whether relying on natural gas or propane, users can trust in the VGL450 series for warmth and comfort.