Installation

Continued

3.Activate the remote handset battery by removing the insulating tab on the back of the handset (see Figure 15). The battery is included pre-installed.

4.Once the battery is activated the unit is ready to use.

5.Replace front refractory access panel.

Battery Cover

12 Volt Battery

Back of

Handset

Pull to Remove

Insulation Tab

Figure 15 - Installing Battery into Back of

Handset

DESA recommends that a black iron gas line be routed from the gas source, through a sediment trap (shown in Figure 18) and into the appliance. Once connected through the appliance, a flexible gas line may be used for ease of installation to gas control valve (see Figure 19, page 13).

Before connecting the black iron gas line to the inside of the appliance a sediment trap must be included outside the appliance between the gas line and the gas shutoff valve. It must extend down three (3) inches beyond the center of the pipe. Prepare incoming black iron gas line with teflon tape or pipe joint compound (Check with local building codes).

Key

Shutoff

Valve

 

Extension

Typical Exterior Wall Gas

Shutoff Installation

Figure 16 - Manual Shutoff Valve

Installation

GAS LINE HOOK-UP

WARNING: Gas line hookup should be done by your gas supplier or a qualified service person.

1/2" NPT Incoming

Black Iron Gas Line

A

7"

7"

Alternate Gas Supply Through Sub-Floor

WARNING: Before you pro- ceed, make sure your gas supply is OFF.

A manual shutoff valve has been included in the appliance’s gas supply system. You may consider installing an extra gas shutoff valve outside the

 

M36E(B,H),

M42E(B,H),

 

M36EP(B,H

M42EP(B,H)

 

VM36E(B,H),

VM42E(B,H),

 

VM36EP(B,H)

VM42EP(B,H)

 

 

 

A

8 5/8" (219 mm)

10 1/2" (267 mm)

Figure 17 - Routing Incoming Gas Line

appliance’s enclosure (check with local codes) where it can be accessed more conveniently with a key through a wall as shown in Figure 16.

In conformance with local codes, route a 1/2" NPT gas line to the appliance through hole in left side of firebox or sub-floor as shown in Figure 17.

Sediment

Trap (Not

Supplied)

3" Min.

(76 mm)

Incoming 1/2" Gas Line Permitted by Local Codes

 

all

 

W

Side

Of

Appliance

 

CAUTION: Do not kink flex- ible gas line.

Figure 18 - Sediment Trap

12

www.desatech.com

108796-01L

Image 12
Contents For Your Safety Table of Contents Safety Information High traffic areas Windy or drafty areasUnpacking IntroductionBefore YOU Begin Possible Locations for Installing Appliance Selecting LocationProduct Specifications M36EB,H M42EB,HPre-Installation Preparation ClearancesMantel Clearances and Wall Details 229 mm 152 mm 12 305 mmRough Opening for Installing Wall FramingVenting Installation Installing Transition Pipe and Starter CollarVent Piping Starter Collar Transition Pipe Vent Collar Typical B-Vent Configuration Roof PitchInstallation Wall Switch InstallationOptional Remote control Installation model WRC Checking for Proper VentingGAS Line HOOK-UP M42EPB,HVM36EB,H Ember and PAN Material placement LOG Placement For M36E, M36EP, VME36 and VM36EP Models Grate Pan and Ember Material Burner PanLog Notch Notches Log NotchLOG Placement For M42E, M42EP, VME42 and VM42EP Models Notch Log Log 2A Log 2BLog Notches Log Notch Log 2BInstalling optional Glass Door Accessory Combustion AIR KIT Model AK4 OptionalAppliance Enclosure Screen Pocket Air Kit HandleOpening Vent Damper SpringClip Screw Side Front Face Partially Opened Door For Your Safety Read Before Lighting Operating FireplaceLighting Instructions EquipmentPilot Assembly Inspecting BurnersTo Turn OFF GAS To Appliance Optional Remote OperationCleaning Maintenance Service HintsTechnical Service Replacement PartsWiring Diagram Pilot Burner Pilot Gas LineTroubleshooting Observed Problem Possible Cause RemedyTroubleshooting Gas leak. See WarningIllustrated Parts Breakdown Parts List VM36EB/VM42EB Logsets for models M36B,H, M36PB,H, VM36B,H and VM36PB,H 108723-01 Top Left LogLogsets for models M42B,H, M42PB,H, VM42B,H and VM42PB,H 107999-02Accessories Fire Crackle CF6-A108796-01L 108796-01L Warranty Information Keep this WarrantyLimited Warranty Vent Fireplace