FMI FVTR18, FVTR24 AIR for Combustion and Ventilation, Providing Adequate Ventilation

Page 4

VENTED NATURAL GAS LOGS

AIR FOR COMBUSTION AND VENTILATION

WARNING: This appliance shall not be installed in a con- fined space or unusually tight construction unless provisions are provided for adequate com- bustion and ventilation air. Read the following instructions to in- sure proper fresh air for this and other fuel-burning appliances in your home.

Today’s homes are built more energy effi- cient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.

While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper com- bustion and ventilation.

Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide ad- equate fresh air for these appliances. This will insure proper venting of vented fuel- burning appliances.

PROVIDING ADEQUATE VENTILATION

The following are excerpts from National Fuel Gas Code, NFPA 54/ANS Z223.1, Sec- tion 5.3, Air for Combustion and Ventilation.

All spaces in homes fall into one of the three following ventilation classifications:

1.Unusually Tight Construction

2.Unconfined Space

3.Confined Space

The information on pages 4 through 6 will help you classify your space and provide adequate ventilation.

Unusually Tight Construction

The air that leaks around doors and win- dows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.

Unusually tight construction is de- fined as construction where:

a.walls and ceilings exposed to the outside atmosphere have a con- tinuous water vapor retarder with a rating of one perm (6x10-11kg per pa-sec-m2) or less with open- ings gasketed or sealed and

b.weather stripping has been added on openable windows and doors and

c.caulking or sealants are applied to areas such as joints around window and door frames, be- tween sole plates and floors, be- tween wall-ceiling joints, be- tween wall panels, at penetra- tions for plumbing, electrical, and gas lines, and at other openings.

If your home meets all of the three criteria above, you must provide ad- ditional fresh air. See Ventilation Air From Outdoors, page 6.

If your home does not meet all of the three criteria above, proceed to De- termining Fresh-Air Flow For Log Set Location, page 5.

Confined and Unconfined Space

The National Fuel Gas Code, ANS Z223.1 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggre- gate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are con- sidered a part of the unconfined space.

This log set shall not be installed in a con- fined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air.

*Adjoining rooms are communicating only if there are doorless passageways or ventila- tion grills between them.

4

901846

Image 4
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualModels FVTR18 FVTR24 Safety Information Vented Natural GAS LogsLocal Codes Unpacking Optional Product Features Product IdentificationAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Appliance Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From InsideBuilding Ventilation Air From OutdoorsInstallation Flue Opening SpecificationsVenting Specifications for Installation Check GAS TypeInstalling Damper Clamp Connecting to GAS SupplyInstallation Items Needed Pressure Testing Gas Supply Piping SystemKit Assembly Hearth KIT Assembly and InstallationInstallation and Gas Connection Natural Gas Installation Propane/LP Gas ConversionTesting Burner for Leaks Adding PAN MaterialInstalling the Ember For Your Safety Read Before LightingOperating Appliance Lighting InstructionsGAS Shutoff Valve Operation Curing LogsOperating Instructions for To Turn OFF GAS To ApplianceTroubleshooting Observed Problem Possible Cause RemedyClean pilot see Cleaning and Mainte Gas leak. See Warning statement at Replacement Parts Cleaning and MaintenanceAccessories Illustrated Parts Breakdown FVTR18Parts List KEY Part Number Description QTYIllustrated PARTS20 Breakdown FVTR24Parts List Vented Natural GAS Logs 901846 Warranty Information International