FMI FVTR18 Operating Appliance, Installing the Ember, For Your Safety Read Before Lighting

Page 12

VENTED NATURAL GAS LOGS

INSTALLATION

Continued

INSTALLING THE EMBER

BED AND LOGS (Split Oak

Sets Shown)

1.Place the ember bed (included with burner set) over log grate as shown in Figure 18.

2.Position the back log flush against back of ember bed as shown in Figure 19.

3.Place the middle layer of logs as shown in Figure 20. Notice the grove in the back log for placement of log to the far right. Adequate space should be left between logs and ember bed for flames.

4.Place the top layer of logs as shown in Figure 21.

Ember Bed

Grate

Figure 18 - Installing Ember Bed

Figure 19 - Installing Back log

Figure 20 - Installing Logs

Figure 21 - Installing Logs

OPERATING

APPLIANCE

FOR YOUR SAFETY

READ BEFORE

LIGHTING

WARNING: Keep flue open when operating unit.

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.

BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information, above.

2.Turn the gas shutoff valve to OFF.

3.Wait five (5) minutes to clear out any gas. If you then smell gas STOP! Fol- low the safety information above. If you don’t smell gas, go on to the next step.

4.Light a match and lay it on top of the “U” shaped burner near the edge of the cover on the right side of the pan.

5.Slowly turn the gas shutoff valve ON until the burner ignites. If the burner doesn’t ignite within 10 seconds with the match burning, turn the shutoff valve OFF and repeat steps 1 through 4 again.

12

901846

Image 12
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASModels FVTR18 FVTR24 Safety Information Vented Natural GAS LogsLocal Codes Unpacking Optional Product Features Product IdentificationAIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceAIR for Combustion Ventilation Determining FRESH-AIR Flow for Appliance LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From InsideBuilding Ventilation Air From OutdoorsInstallation Flue Opening SpecificationsVenting Specifications for Installation Check GAS TypeInstalling Damper Clamp Connecting to GAS SupplyInstallation Items Needed Pressure Testing Gas Supply Piping SystemHearth KIT Assembly and Installation Kit AssemblyInstallation and Gas Connection Natural Gas Installation Propane/LP Gas ConversionTesting Burner for Leaks Adding PAN MaterialInstalling the Ember For Your Safety Read Before LightingOperating Appliance Lighting InstructionsGAS Shutoff Valve Operation Curing LogsOperating Instructions for To Turn OFF GAS To ApplianceTroubleshooting Observed Problem Possible Cause RemedyClean pilot see Cleaning and Mainte Gas leak. See Warning statement at Cleaning and Maintenance Replacement PartsAccessories Illustrated Parts Breakdown FVTR18Parts List KEY Part Number Description QTYIllustrated PARTS20 Breakdown FVTR24Parts List Vented Natural GAS Logs 901846 Warranty Information International