Vermont Casting EWF36A installation instructions Chimney Requirements Offset Installations

Page 6

Vermont Castings EWF36A

Chimney Requirements - Offset Installations

CHIMNEY FLUE EXIT

 

 

Chimney

 

 

 

 

Section

 

 

 

 

Elbow

 

30°

 

 

 

Return

A

 

B

G

Elbow

 

 

 

 

 

 

 

 

30°

G

 

 

 

 

D

 

 

Offset

 

E

Rise

Elbow

 

 

 

 

C

6 FT.

 

30°

TCS8A

 

 

 

 

H

Return

Support

 

Offset

Elbow

 

 

 

 

H

 

 

 

30°

B

 

 

 

 

 

Offset

 

 

 

 

Elbow

 

 

Hearth

 

 

 

 

Floor

 

 

 

Example 1

 

Example 2

 

Example 3

Notes: G + H cannot exceed 20 feet.

 

FP269

 

 

Air Space Clearances: “S” Series (3-wall) = 2” Min. to Combustibles

Offset

Rise

 

 

 

 

 

 

 

FP282

 

 

 

 

 

30˚ Elbow Offsets

 

 

 

 

 

 

 

 

1’ 1¹⁄₂'

3’

4’

Chimney Support

Offset

Rise

 

 

 

 

 

 

 

 

0

0

0

0

0

3”

11”

 

1

0

0

0

0

8¹⁄"

20"

 

0

1

0

0

0

11¹⁄" 25¹⁄"

 

2

0

0

0

0

13¹⁄" 29¹⁄"

 

1

1

0

0

0

16¹⁄" 34¹⁄"

 

0

0

1

0

0

20¹⁄" 40³⁄"

 

2

1

0

0

0

21³⁄" 43¹⁄"

 

0

0

0

1

0

26¹⁄" 51¹⁄"

 

0

1

1

0

0

28¹⁄" 55¹⁄"

 

1

0

0

1

0

31¹⁄" 60¹⁄

 

0

1

0

1

0

34¹⁄" 65¹⁄"

 

0

0

2

0

0

37¹⁄" 70³⁄"

 

1

1

0

1

1

41¹⁄" 77³⁄"

 

0

0

1

1

1

45" 83³⁄"

 

0

1

2

0

1

47¹⁄" 87¹⁄"

 

0

0

0

2

1

51"

94"

 

0

1

1

1

1

53¹⁄"

98"

 

0

0

3

0

1

56¹⁄"

103¹⁄"

Illustration Key

The following safety rules apply to offset installations (letters correspond with illustration above):

A. Height of the chimney is measured from the hearth to the chimney exit.

 

EWF36A

Maximum:

50’

Minimum:

 

Without Elbows

17’0”

With 2 Elbows*

19’0”

With 4 Elbows*

21’0”

B. Do not use more than 4 elbows per chimney.

Attach the straps of the return (top) elbow to a structural framing member.

The offset (first) elbow of any pair does not have straps.

C. The chimney cannot be more than 30˚ (45˚ in Canada) from the vertical plane in any installation*.

D. The maximum length of the angled run of the total chimney system is 20 feet. (G plus H cannot exceed 20 feet.)

E. A chimney support (Model TCS8A) is required every 6 feet of angled run of chimney. Chimney supports are required for every 30 feet and 60 feet of vertical chimney height above the hearth.

Determine the offset distance of your chimney arrangement from the centerline of the fireplace to the centerline of the chimney where it is to pass through the first ceiling.

NOTE: This offset distance may not be your full offset distance. See Examples 2 and 3.

0

1

0

2

1

59¹⁄" 108¹⁄"

0

0

2

1

1

62¹⁄" 113¹⁄"

0

1

3

0

1

64¹⁄" 117¹⁄"

0

0

1

2

1

68¹⁄"

124"

0

1

2

1

1

70¹⁄"

128"

0

0

0

3

1

74¹⁄" 134¹⁄"

0

1

1

2

2

78" 140³⁄"

0

0

3

1

2

81"

146"

0

1

0

3

2

84" 151¹⁄"

0

0

2

2

2

87" 156¹⁄"

0

1

3

1

2

89¹⁄" 160¹⁄"

0

0

1

3

2

93" 166³⁄"

0

1

2

2

2

95¹⁄" 170³⁄"

0

0

0

4

2

99¹⁄" 177³⁄"

0

1

1

3

2

101¹⁄" 181³⁄"

0

0

3

2

2

104¹⁄" 186¹⁄"

0

1

0

4

2

107¹⁄" 191¹⁄"

0

0

2

3

2

110¹⁄" 196³⁄"

0

1

3

2

3

114" 203¹⁄"

0

0

1

4

3

117³⁄" 209³⁄"

0

1

2

3

3

120" 213¹⁄"

0

0

0

5

3

123³⁄"

220"

Fig. 3 Chimney system requirements.

6

20005167

Image 6
Contents EWF36A Table of Contents IntroductionDescription Safety InformationPrecautions DraftsSpecifications EWF36A Woodburning FireplaceChase Installation Fireplace and chase parts identificationChimney Requirements Offset Installations Planning the Chimney Run Planning InformationMounting the Fireplace Ten Foot RuleInstallation Chimney SupportsInsulating Fireplace Enclosure for Cold Climates Framing Straight-Up Chimney InstallationOffset Installation EB1 Receptacle HookupCutting the Hole Positioning, Safety Strips Securing the FireplaceCeiling Chimney Hole Possible Obstructions Framing the Ceiling HoleInstallating Outside Air Kit Installation PrecautionsInstallation Instructions Installing the Chimney System Installing the Firestop Spacer Ceiling HoleProper Firestop Spacer Installation Additional Ceilings Continue Installing Pipe to Complete RunCanadian Requirements For Insulation Shield Penetrating the RoofInstalling Chimney in a Chase Install Remainder of Chimney SectionsInstall Top Housing or Termination Finishing Finish WallSide Wall Protection Hearth InstallationMantels Examples of wall shield insulationCommon Materials and Factors Minimum Wall Clearances EWF36A Controls OperationAttach Handles Primary Air ControlGlass Doors Use the Air Control Settings That Work Best for YouFan Burn Only High-Quality WoodStarting and Maintaining a Wood Fire Reloading and Reviving a Wood FireSpecial Tactics for Cold-Climate Heating Remove and Store Ash Safely Maintenance How to Replace Gaskets When to Suspect a Combustor ProblemRemoving, Cleaning or Replacing the Combustor Inspecting the CombustorReplacing the Door Gaskets Clean Chimney System is Safer and Works BetterChimney System Replace Damaged Door Glass ImmediatelyMaintenance Schedule Yearly Spring CleaningFireplace Daily Chimney Components TCS8AEWF36A Fireplace EWF36A Fireplace Trim Kits Optional AccessoriesFan Kit Screen KitVermont Castings EWF36A Warranty CFM Corporation