Desa Tech CHDV41N, CHDV41P, CHDV37P, CHDV37N Specifications, Accessories, Manual Blower KIT GA3750

Page 33

OWNER’S MANUAL

SPECIFICATIONS

 

CHDV37N

CHDV37P

CHDV41N

CHDV41P

Btu

17,000/24,000 Btu/h

17,000/22,000 Btu/h

18,000/26,000 Btu/h

19,000/24,000 Btu/h

 

 

 

 

 

Gas Type

Natural

Propane/LP

Natural

Propane/LP

 

 

 

 

 

Ignition

Piezo

Piezo

Piezo

Piezo

 

 

 

 

 

Manifold Pressure

3.5" w.c.

10.0" w.c.

3.5" w.c.

10.0" w.c.

 

 

 

 

 

Minimum Inlet Supply Pressure

4.5" w.c.

11.0" w.c.

4.5" w.c.

11.0" w.c.

 

 

 

 

 

Thermal Efficiency

70%

70%

70%

70%

 

 

 

 

 

Dimension, Inches/mm (HxWxD)

 

 

 

 

Fireplace

33" x 37" x 18 1/2"

33" x 37" x 18 1/2"

33" x 41" x 18 1/2"

33" x 41" x 18 1/2"

 

838 x 940 x 470mm

838 x 940 x 470mm

838 x 1041 x 470mm

838 x 1041 x 470mm

Carton

37" x 43" x 21"

37" x 43" x 21"

37" x 47" x 21"

37" x 47" x 21"

 

940 x 1092 x 533mm

940 x 1092 x 533mm

940 x 1194 x 533mm

940 x 1194 x 533mm

 

 

 

 

 

Weight, lbs/kg

 

 

 

 

Fireplace

132 lbs/60 kg

132 lbs/60 kg

142 lbs/64 kg

142 lbs/64 kg

Shipping

135 lbs/61 kg

135 lbs/61 kg

145 lbs/66 kg

145 lbs/66 kg

 

 

 

 

 

ACCESSORIES

Purchase these fireplace accessories from your local retailer. If they can not supply these accessories, call DESA International’s Sales Department at 1-800-432-2382. for information. You can also write to the ad- dress listed on the back page of this manual.

BRASS PERIMETER TRIM KIT CD9037(37")/CD9041(41") (Not Shown)

Optional three sided brass trim kit. Provides a finished appearance with the class of brass.

BRICK LINER CD8037(37")/ CD8041(41")

(Not Shown)

This brick liner adds a touch of style to your direct-vent fireplace. Complete installation and operation instructions included in this manual.

MANUAL BLOWER KIT GA3750

Manualvariablecontrolbloweraccessory pro- vides better heat distribution. Complete in- stallation and operation instructions included in this manual.

THERMOSTATICALLY- CONTROLLED BLOWER KIT - CDA3620T

Provides better heat distribution. Blower turns off and on automatically, as needed. Complete installation and operation instruc- tions included in this manual.

FREE-STANDING CABINET MANTEL WITH SQUARE LEG STYLING - UNFINISHED GMC511U(37")/GMC513U(41")

For use with all models. This oak-veneer mantel is unfinished and ready to stain or paint. Complete assembly instructions are in- cluded along with a three-sided perimeter brass trim kit to cover unfinished fireplace edges. This free-standing cabinet mantel allows the unit to be installed against any wall without recessing fireplace.

104605

33

Image 33
Contents For Your Safety For Your Safety What to do if YOU Smell GASCHDV37N, CHDV37P CHDV41N, and CHDV41P CHDV37N/P and CHDV41N/P Safety InformationProduct Identification Product FeaturesLocal Codes Glossary TermsLocation and Space Requirements PRE-INSTALLATION PreparationClearances Framing and FinishingLocation of Vent Termination PRE-INSTALLATION Preparation General VentingGeneral Venting Installation Precautions Venting InstallationInstallation Planning Installing Vent System in a ChaseSnorkel Termination Installation for Horizontal TerminationVent Pipe Connections Horizontal Venting Horizontal Termination ConfigurationsVenting with Two 90 Elbows Installation for Vertical Termination Flat Ceiling InstallationCathedral Ceiling Installation Venting with One 90 Elbow Vertical Termination ConfigurationsVertical Venting Vertical Rigid Venting Configuration Using Two 90 ElbowsParts Lists for Venting Kits and Components High Altitude InstallationComfort Glow Rigid Venting Comfort Glow Flexible VentingInstalling Optional Blower Accessory Fireplace InstallationInstalling GA3750/CDA3620T Blowers Check GAS TypePlug in blower power cord Installation Items Needed Installing GAS Piping to Fireplace LocationInstallation Items Needed Connecting Fireplace to GAS SupplyPressure Testing Gas Supply Piping System Checking GAS ConnectionsClose manual shutoff valve see Fig- ure Pressure Testing Fireplace Gas ConnectionsWireless HAND-HELD Remote Control Accessory Ghrct Installing Optional Wall Mounted Thermostat GWMT1Included Installing Battery into Receiver Installing 9-Volt Battery in Hand- Held Remote Control UnitAttaching Magnetic Decorative Brass Strips REMOVING/REPLACING Glass DoorInstalling Optional Brick Liner CD8037/CD8041 Fireplace Models CHDV37N/P and CHDV41N/P Installing LOGS, Lava Rock and Glowing EmbersManual Lighting Procedure For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsHAND-HELD Remote Operation Operating Optional Blower AccessoryInspecting Burners Pilot AssemblyOperating Optional GWMT1 Wall Mounted Thermostat Burner Flame PatternGlass Door Cleaning and MaintenancePilot and Burners LogsObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Above Gas leak. See Warning statementService Hints Replacement Parts Wiring DiagramTechnical Service Parts Under WarrantyAccessories SpecificationsManual Blower KIT GA3750 THERMOSTATICALLY- Controlled Blower KIT CDA3620TCHDV37N CHDV41N Illustrated Parts BreakdownDIRECT-VENT Fireplace CHDV37N CHDV41N Parts ListCHDV37P CHDV41P DIRECT-VENT Fireplace CHDV37P and CHDV41P Warranty Information