AIR FOR COMBUSTION AND VENTILATION

Continued

WARNING

WARNING ICON

G 001

If the area in which the heater may be operated is smaller than that defined as an unconfined space, provide adequate combus- tion and ventilation air by one of the methods described in the National Fuel Gas Code, ANSI Z223.1, 1992, Section 5.3.

VENTILATION AIR

Ventilation Air From Inside Building

This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 2). Follow the National Fuel Gas Code NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

WARNING

WARNING ICON

G 001

 

 

Rework worksheet, adding the space of the adjoining unconfined space. The combined spaces must have enough fresh air to supply all appliances in both spaces.

Ventilation

Grills

Into Adjoining

12"

Ventilation Grills

Into Adjoining Room,

Room,

Or

Option 2

Option 1

Remove

Door into Adjoining Room, Option 3

12"

Figure 2 - Ventilation Air from Inside Building

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two perma- nent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces.

IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat- controlled power vent. Heated air entering the attic will activate the power vent.

 

Outlet

Ventilated

 

 

Attic

 

 

Air

 

 

 

 

Outlet

 

 

 

Air

 

To Attic

 

 

 

 

 

 

To

 

 

 

Crawl

 

Inlet

 

Space

 

 

 

 

Air

 

 

 

 

Inlet Air

Ventilated

 

 

Crawl Space

 

 

 

 

Figure 3 - Ventilation Air from Outdoors

7

102991

Image 7
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information 001 Piezo Ignition System Local Codes Unpacking Product FeaturesSafety Device OperationUnconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space Determining AIR Flow for Heater LocationVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Check GAS Type InstallingHigh traffic areas Windy or drafty areas LOG Sizing Requirements Minimum Fireplace ClearanceMinimum Wall and Ceiling Clearances see Figure Minimum Non Combustible Material Clearances If Using Mantel Floor Clearances Attaching Damper Clamp Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Installing Heater Base AssemblyAttaching Base Assembly to Fireplace Floor Connecting to GAS SupplyExternal Regulator With Vent Pointing Down Checking GAS Connections Pressure Testing gas Supply Piping systemTest Pressures Equal To or Less Than 1/2 Psig Installing Back Log #1 Installing LogsOperating Heater For Your Safety Read Before LightingVariable Control Operation Manual Lighting Procedure Control Knob Ignitor Button Pilot Flame Pattern Inspecting BurnersThermostat-Controlled Models Only Logs Cleaning and Maintenance Trouble ShootingTurn off heater and let cool before cleaning ODS/PILOT and BurnerTROUBLE- Shooting Cleaning and MainteRefer to Air for Com Gas leak. See Warning Optional Positioning of Thermostat Sensing Bulb Installing Thermostat Sensing Bulb behind Glass Doors Service Hints Technical ServiceModel Models Parts Not Under Warranty Parts Under WarrantyParts Central Hood GA6052 AccessoriesValve GA5010 Hood GA6050Illustrated Parts Breakdown CGD3018P CGD3924P CGD3930P Parts ListCGD3924PT CGD3924PT 102991 102991 Keep this Warranty Warranty Information

CGD3924P, CGD3018P, CGD3930P specifications

The Desa Tech CGD3924P, CGD3930P, and CGD3018P represent a trio of high-performance gas fireplaces designed for modern home heating. These models are engineered to prioritize efficiency, style, and user comfort, making them an attractive addition to any living space.

The CGD3924P is a versatile fireplace primarily known for its contemporary front design and compact size, suitable for smaller rooms. It features a dual burner system, which enhances the flame presence and warmth distribution. The unit operates on natural gas and includes a built-in blower, facilitating effective heat circulation throughout the area. Its adjustable flame height allows users to customize the ambiance, while the realistic log set contributes to the fireplace's authentic aesthetic.

Moving on to the CGD3930P, this model boasts a larger viewing area, offering an impressive flame display that becomes the focal point of any room. Its innovative technology features an advanced electronic ignition system for easy lighting and operation. This unit is designed with energy efficiency in mind, achieving high AFUE ratings that help reduce heating costs. The CGD3930P also includes a thermostatic remote control, providing convenience for users to adjust settings from across the room.

Lastly, the CGD3018P is a traditional-style fireplace that caters to homeowners seeking a classic charm. With detailed craftsmanship and an antique finish, it provides an inviting atmosphere. This unit features a single burner system, ideal for smaller spaces, delivering modest yet reliable heat output. The CGD3018P’s user-friendly design emphasizes ease of maintenance, highlighting its accessibility for routine care.

All three models utilize high-quality materials that enhance durability and safety, ensuring long-lasting performance. The fireplaces are equipped with safety features such as auto shut-off systems and venting options that comply with national safety standards.

In terms of installation, each unit provides flexible venting options, including direct vent capabilities, allowing for various setups to meet specific home requirements.

Ultimately, the Desa Tech CGD3924P, CGD3930P, and CGD3018P stand out in the market for their combination of cutting-edge technologies, aesthetic appeal, and user-friendly features, making them ideal choices for modern heating solutions in homes today.