Desa Tech CGD3018P, CGD3924P, CGD3930P installation manual 001

Page 3

SAFETY INFORMATION

Continued

WARNINGS Continued

WARNING ICON

G 001

WARNING: Any change to this heater or its controls can be dangerous.

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.Do not place propane (LP) supply tank(s) inside any structure. Locate propane (LP) supply tank(s) outdoors.

3.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

4.This heater shall not be installed in a bedroom or bathroom.

5.Never install the heater

in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater

in high traffic areas

in windy or drafty areas

6.Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. Inspect chimney flue for damage. If damaged, operate heater with flue damper closed.

7.If fireplace has glass doors, never operate this heater with glass doors closed. If you operate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Also if fireplace opening has vents at the bottom, you must open the vents before operating heater.

8.You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater.

9.This log heater is designed to be smokeless. If logs ever appear to smoke, turn off heater and call a qualified service person. Note: During initial operation, slight smoking could occur due to log curing and heater burning manufacturing residues.

10.Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can cause sooting.

11.Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this heater.

12.This heater needs fresh, outside air ventilation to run properly. This heater has an oxygen depletion sensor (ODS) pilot light safety system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, pages 5 through 8. If heater keeps shutting off, see Troubleshooting, pages 25 through 28.

13.Do not run heater

where flammable liquids or vapors are used or stored

under dusty conditions

14.Do not use this heater to cook food or burn paper or other objects.

15.Never place any objects on the heater.

16.Heater base assembly becomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will remain hot for a time after shut-down. Allow surface to cool before touching.

17.Carefully supervise young children when they are in the room with heater.

18.Do not use heater if any part has been exposed to or under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.

19.Do not operate heater if any log is broken. Do not operate heater if a log is chipped (dime- sized or larger).

20.Turn heater off and let cool before servicing. Only a qualified service person should service and repair heater.

21. Operating heater above elevations of 4,500 feet could cause pilot outage.

3

 

 

102991

Image 3
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information 001 Piezo Ignition System Local Codes Unpacking Product FeaturesSafety Device OperationUnconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionDetermining if You Have a Confined or Unconfined Space Determining AIR Flow for Heater LocationVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installing Check GAS TypeHigh traffic areas Windy or drafty areas Minimum Fireplace Clearance LOG Sizing RequirementsMinimum Wall and Ceiling Clearances see Figure Minimum Non Combustible Material Clearances If Using Mantel Floor Clearances Attaching Damper Clamp Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Installing Heater Base AssemblyAttaching Base Assembly to Fireplace Floor Connecting to GAS SupplyExternal Regulator With Vent Pointing Down Checking GAS Connections Pressure Testing gas Supply Piping systemTest Pressures Equal To or Less Than 1/2 Psig Installing Back Log #1 Installing LogsOperating Heater For Your Safety Read Before LightingVariable Control Operation Manual Lighting Procedure Control Knob Ignitor Button Inspecting Burners Pilot Flame PatternThermostat-Controlled Models Only Logs Cleaning and Maintenance Trouble ShootingTurn off heater and let cool before cleaning ODS/PILOT and BurnerTROUBLE- Shooting Cleaning and MainteRefer to Air for Com Gas leak. See Warning Optional Positioning of Thermostat Sensing Bulb Installing Thermostat Sensing Bulb behind Glass Doors Technical Service Service HintsModel Models Parts Under Warranty Parts Not Under WarrantyParts Central Hood GA6052 AccessoriesValve GA5010 Hood GA6050Illustrated Parts Breakdown CGD3018P CGD3924P CGD3930P Parts ListCGD3924PT CGD3924PT 102991 102991 Keep this Warranty Warranty Information

CGD3924P, CGD3018P, CGD3930P specifications

The Desa Tech CGD3924P, CGD3930P, and CGD3018P represent a trio of high-performance gas fireplaces designed for modern home heating. These models are engineered to prioritize efficiency, style, and user comfort, making them an attractive addition to any living space.

The CGD3924P is a versatile fireplace primarily known for its contemporary front design and compact size, suitable for smaller rooms. It features a dual burner system, which enhances the flame presence and warmth distribution. The unit operates on natural gas and includes a built-in blower, facilitating effective heat circulation throughout the area. Its adjustable flame height allows users to customize the ambiance, while the realistic log set contributes to the fireplace's authentic aesthetic.

Moving on to the CGD3930P, this model boasts a larger viewing area, offering an impressive flame display that becomes the focal point of any room. Its innovative technology features an advanced electronic ignition system for easy lighting and operation. This unit is designed with energy efficiency in mind, achieving high AFUE ratings that help reduce heating costs. The CGD3930P also includes a thermostatic remote control, providing convenience for users to adjust settings from across the room.

Lastly, the CGD3018P is a traditional-style fireplace that caters to homeowners seeking a classic charm. With detailed craftsmanship and an antique finish, it provides an inviting atmosphere. This unit features a single burner system, ideal for smaller spaces, delivering modest yet reliable heat output. The CGD3018P’s user-friendly design emphasizes ease of maintenance, highlighting its accessibility for routine care.

All three models utilize high-quality materials that enhance durability and safety, ensuring long-lasting performance. The fireplaces are equipped with safety features such as auto shut-off systems and venting options that comply with national safety standards.

In terms of installation, each unit provides flexible venting options, including direct vent capabilities, allowing for various setups to meet specific home requirements.

Ultimately, the Desa Tech CGD3924P, CGD3930P, and CGD3018P stand out in the market for their combination of cutting-edge technologies, aesthetic appeal, and user-friendly features, making them ideal choices for modern heating solutions in homes today.