OPTIONAL HEATER ACCESSORY Continued
1.Open the upper control door (see Figure 11, on page 6) and remove the 2 Phillips screws below heater grill. See Figure 19.
2.Remove 2 Phillips screws holding the control cover to the control panel inside the firebox (see Figure 20).
3.Slide the control cover to the right and swing out the locking tabs from the notched openings on top. See detail on Figure 20.
4.Let the control cover hang down off the harnesses. Be careful not to damage any wiring. If necessary you can unscrew the harness strap at the blower mount to gain slack. See Figure 21.
5.Remove the 2 Hex screws at rear blower mount. See Figure 20.
6.Slide the blower mount towards the rear firebox until the locking tabs line up with the notched openings and lower the mount down and away. See detail Figure 20.
7.Remove the blower/heater assembly with 4 screws from the packaging. The blower is
8.Align blower assembly over hole pattern on blower mount and attach with 4 pan head screws provided. See Figures 21 or 22.
9.With the discharge pointing towards you, guide the assembled blower mount into the firebox and center the rear mounting flanges between the standoff brackets against the rear firebox.
10.Lift the blower mount up and position the 4 locking tabs through the notched openings in the firebox top, then slide the assembly forward until locked into position.
11.Remove the control panel knockout plug located in the heater switch position by depressing the locking tabs and pushing the plug out through the front of the panel. See Figure 23.
12.Firmly insert the red power switch, provided, into the open mount location with the “ON” ( I ) indicator positioned on top.
TAB RELEASE
PANEL
SCREWS
CONTROL COVER
BLOWER MOUNT
ELECTRIC FIREPLACE 9 INSTALLATION INSTRUCTIONS
Models: (V)E32L, (V)E32LB, (V)E32LH, (V)E32LBH (V)E36L, (V)E36LB, (V)E36LH and (V)E36LBH
HEATER/BLOWER.
ASSEMBLY
BLOWER MOUNT
HARNESSMOUNTING
STRAPSCREWS
Figure 21 - Mounting Heater/Blower
MOUNTING
SCREWS
HEATER/BLOWER.
ASSEMBLY
BLOWER MOUNT
Figure 22 – Mounting Alternate Blower/Heater
KNOCKOUT PLUG
MOUNT LOCATION
CONTROL PANEL
POWER
SWITCH
MOUNT LOCATION
CONTROL PANEL
Figure 20 – Disassembling Blower Mount | Figure 23 - Installing Heater Power Switch |