Desa E36(L)(B)(H) Technical Service, ELECTRIC FIREPLACE 13 INSTALLATION INSTRUCTIONS

Models: E32, VE36, VE32 E36(L)(B)(H)

1 26
Download 26 pages 15.92 Kb
Page 13
Image 13
TECHNICAL SERVICE

TECHNICAL SERVICE

Disconnect power before attempting any maintenance or cleaning to reduce the risk of fire, electrical shock or personal injury.

Any electrical repairs or rewiring of this unit should be carried out by a licensed electrician in accordance with national and local codes.

Do not exceed 100 Watts per bulb when replacing bulbs. Use of higher-rated bulbs may result in fire, causing property damage, personal injury, or loss of life.

Replacing Light Bulbs

There are (3) colored lamps rated at 120V, 100 Watts, for use in a medium sized socket. These bulbs are located under the log bed and can be replaced as follows:

1.If you are unsure which bulb need replacement, defective bulbs may be visually located as any of 3 bulbs colored – Red, Yellow and Orange starting from the left (see Figure 10, page 6). Defective bulbs can be replaced individually or for convenience you may want to replace all the light bulbs even if only one is defective.

2.Disconnect power to the unit at the main breaker or fuse panel.

3.Lift the log bed off the hearth base to gain access to the lamp fixtures; log bed is attached with contact magnets only.

4.Remove each defective bulb from its socket, and replace with the appropriate color and size bulb.

NOTE: be careful not to tear or damage the reflective ribbon. If they have come loose, they can be easily reattached or replaced at the support brackets. See – Replacing Reflective Ribbons, page 18.

5.Return power to the circuit and turn main power switch and lamp power on to check the operation of the bulbs before replacing the log set.

6.If all the bulbs are working properly replace the log bed over the center opening in between the rear screen and front grate.

Make sure the power is turned off at the supply prior to disassembling this unit.

ELECTRIC FIREPLACE 13 INSTALLATION INSTRUCTIONS

Models: (V)E32L, (V)E32LB, (V)E32LH, (V)E32LBH (V)E36L, (V)E36LB, (V)E36LH and (V)E36LBH

Removing/Replacing Control Door

The upper control door may be removed for service or replacement when necessary:

1.Open the upper control door. See Figure 11, page 6.

2.Remove 4 Phillips screws above the heater grill and angle the deflector shield out the opening. See Figure 29.

3.Remove the 4 Phillips screws with magnet assemblies.

4.Lift up on the inner control door and push in each end until the pivot pins are free of the notches located on each side of the access opening. See Figure 29.

5.Rotate the control door up into the control compartment and slide one end into the side of the compartment.

6.Tilt out one end first then pull the remaining door assembly through the opening.

7.Replace the door, by starting with door upside down and pins facing the unit. Follow steps 1 through 5 in reverse.

8.Replace the discharge deflector and magnet assemblies.

DISCHARGE

DEFLECTOR

LOUVER

END VIEW

DOOR

 

MAGNET

ASSEMBLY

LOUVER

 

DOOR

END VIEW

 

Maintaining Motors

Motors used on the fan and heater assembly are permanently lubricated do not require lubrication. Annual cleaning and/or vacuuming around the heater and fan unit is recommended.

LOUVER

END VIEW

DOOR

Figure 29 – Removing/Replacing Control Door

For more information, visit www.desatech.com

111076-01C

Page 13
Image 13