TECHNICAL SERVICE
Disconnect power before attempting any maintenance or cleaning to reduce the risk of fire, electrical shock or personal injury.
Any electrical repairs or rewiring of this unit should be carried out by a licensed electrician in accordance with national and local codes.
Do not exceed 100 Watts per bulb when replacing bulbs. Use of
Replacing Light Bulbs
There are (3) colored lamps rated at 120V, 100 Watts, for use in a medium sized socket. These bulbs are located under the log bed and can be replaced as follows:
1.If you are unsure which bulb need replacement, defective bulbs may be visually located as any of 3 bulbs colored – Red, Yellow and Orange starting from the left (see Figure 10, page 6). Defective bulbs can be replaced individually or for convenience you may want to replace all the light bulbs even if only one is defective.
2.Disconnect power to the unit at the main breaker or fuse panel.
3.Lift the log bed off the hearth base to gain access to the lamp fixtures; log bed is attached with contact magnets only.
4.Remove each defective bulb from its socket, and replace with the appropriate color and size bulb.
NOTE: be careful not to tear or damage the reflective ribbon. If they have come loose, they can be easily reattached or replaced at the support brackets. See – Replacing Reflective Ribbons, page 18.
5.Return power to the circuit and turn main power switch and lamp power on to check the operation of the bulbs before replacing the log set.
6.If all the bulbs are working properly replace the log bed over the center opening in between the rear screen and front grate.
Make sure the power is turned off at the supply prior to disassembling this unit.
ELECTRIC FIREPLACE 13 INSTALLATION INSTRUCTIONS
Models: (V)E32L, (V)E32LB, (V)E32LH, (V)E32LBH (V)E36L, (V)E36LB, (V)E36LH and (V)E36LBH
Removing/Replacing Control Door
The upper control door may be removed for service or replacement when necessary:
1.Open the upper control door. See Figure 11, page 6.
2.Remove 4 Phillips screws above the heater grill and angle the deflector shield out the opening. See Figure 29.
3.Remove the 4 Phillips screws with magnet assemblies.
4.Lift up on the inner control door and push in each end until the pivot pins are free of the notches located on each side of the access opening. See Figure 29.
5.Rotate the control door up into the control compartment and slide one end into the side of the compartment.
6.Tilt out one end first then pull the remaining door assembly through the opening.
7.Replace the door, by starting with door upside down and pins facing the unit. Follow steps 1 through 5 in reverse.
8.Replace the discharge deflector and magnet assemblies.
DISCHARGE
DEFLECTOR
LOUVER | END VIEW | |
DOOR | ||
|
MAGNET
ASSEMBLY
LOUVER |
|
DOOR | END VIEW |
|
Maintaining Motors
Motors used on the fan and heater assembly are permanently lubricated do not require lubrication. Annual cleaning and/or vacuuming around the heater and fan unit is recommended.
LOUVER | END VIEW |
DOOR |
Figure 29 – Removing/Replacing Control Door