10 ELECTRIC FIREPLACE INSTALLATION INSTRUCTIONS
Models: (V)E32L, (V)E32LB, (V)E32LH, (V)E32LBH (V)E36L, (V)E36LB, (V)E36LH and (V)E36LBH
OPTIONAL HEATER ACCESSORY Continued
13.Connect White heater wire to neutral connection marked ‘B’ or ‘A’ on terminal block. See partial wiring diagram, Figure 24.
14.Connect Black heater wire to terminal marked
Note: On alternate style heaters the White and Black wires are connected common at terminal
15.Connect Red heater wire to terminal marked
16.Connect one end of the Black jumper lead, provided in the kit, to the power connection marked ‘D’ on the terminal block and the other end to switch terminal marked
17.Replace the 2 Hex screws on rear flanges of the blower mount.
18.Remount the harness strap to the blower mount, if removed.
19.Make sure all wires are clear of the heater discharge area, line up the mounting holes on the front blower mount to the holes in the control panel and replace the 2 black pan head screws.
20.Raise the control cover up and position the 2 locking tabs through the notched openings in the firebox top, then slide to the left until locked into position. See Figure 20, page 9.
21.Tuck any excess slack in harnesses into control cover, swing cover down to
22.Restore power to the unit and check operation of the heater.
IMPORTANT: Be sure to inspect the components and wiring for damage before connecting power to the unit. If any components are found damaged, contact an authorized dealer for original DESA replacement part(s) or call DESA at
| BLK (NOIR) | WHT (BLANC) | CUTOUT | MOTOR |
GRN |
| WHT | COUPE- | MOTEUR |
BLK (NOIR) | (BLANC) | CIRCUIT |
|
(VERTE) |
| D | C | B | A | (BLANC - ALTERNATIF) | WHT |
| WHT (BLANC) |
| TERMINAL |
|
| WHT - ALTERNATE | (BLANC) |
|
|
|
|
|
|
| |
| HARNESS 4" | BLK |
|
|
|
|
CABLAGE (10 cm) NOIR |
|
|
| BLK | RED | ||
|
|
| L N 1 HEATER POWER | (NOIR) | (ROUGE) | ||
SUPPLY |
| 4 |
|
| |||
|
|
| COURANT DE |
| HEATER COIL | ||
CONNECTION |
| 5 | L |
| |||
BLK | L'CHAUFFAGE | BLK | RADIATEUR | ||||
CONNEXION |
|
| |||||
(NOIR) |
|
|
| (NOIR) |
| ||
D'ALIMENTATION |
|
|
|
| |||
|
|
|
|
|
| ||
WIRES TO HEATER CIRCUIT |
| RED |
|
|
| ||
(ROUGE) |
|
|
|
FILS À CIRCUIT D'CHAUFFAGE
Figure 24 - Heater Circuit Connection Diagram
CONTROL PANEL
TERMINAL BLOCK
WHITE
| HEATER/BLOWER |
ROCKER | BLACK |
SWITCH | RED |
|
Figure 25 - Connecting Heater Wires
CONTROL PANEL
TERMINAL BLOCK
WHITE
ROCKER | WHITE |
|
SWITCH |
| |
|
| |
| RED | HEATER/BLOWER |
|
|
Figure 26 - Connecting Alternate Heater Wires
CONTROL PANEL
TERMINAL (D)
JUMPER LEAD
SWITCH
TERMINAL
Figure 27 - Connecting Jumper Lead
For more information, visit www.desatech.com