Empire Comfort Systems VFP36PP32EN-2 Dual Switch Electrical Wiring to Fireplace Receptacle

Page 25

WIRING INSTRUCTIONS FOR INSTALLING A DUAL SWITCH / RECEPTACLE

In order to install both the optional Blower and Accent Light ac- cessories, it will be necessary to install the junction box so that the Duplex Receptacle wiring is split. This will allow each side of the receptacle to operate independently off separate wall switches. See diagram below.

CAUTION: ALL WIRING SHOULD BE DONE BYA QUAL- IFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITHALLLOCAL, CITYAND STATE BUILDING CODES. BEFORE MAKING THE ELECTRICAL CONNECTION, MAKE SURE THAT MAIN POWER SUPPLY IS DISCON- NECTED. THE APPLIANCE, WHEN INSTALLED, MUST BE ELECTRICALLY GROUNDED IN ACCORDANCE WITH LOCAL CODES OR, IN THE ABSENCE OF LOCAL CODES, WITH THE NATIONAL ELECTRICAL CODE ANSI/NFPA 70 (LATEST EDITION).

#1

ACCENT LIGHT WALL SWITCH

 

#2

REMOVE TAB ON HOT SIDE

 

 

BLOWER

OF DUPLEX RECEPTACLE

 

 

WALL

TO SPLIT LUGS

 

 

SWITCH

 

 

 

BLACK

RED

 

TO 120V

WHITE

BLACK

 

 

 

CIRCUIT

 

WHITE

 

BREAKER

 

 

 

GROUND

 

 

 

 

 

FIREPLACE

 

DOUBLE SWITCH BOX

3-WIRE, GROUNDED

CONTROL

 

CONDUCTOR

COMPARTMENT

 

(INSTALLER PROVIDED)

 

(BY OTHERS)

 

 

 

 

DUAL SWITCH ELECTRICAL WIRING TO FIREPLACE RECEPTACLE

PLUG

FOR CONTROLS

PLUG

FOR BLOWER

1.To wire Junction Box Receptacle, remove the tab on the side of the receptacle (hot side) to split receptacle. This will be required to separate blower and Accent Light circuits.

2.Power for switched and live sides of Duplex Receptacle must come from the same power source. (One circuit breaker on main panel must switch all power off.)

3.From the wall box to the fireplace a 3-wire conductor with ground is recommended, however (2) two-wire conductors with grounds may be used in place of a 3-wire conductor with a ground if the black wires from the Accent Light and blower accessories are identified.

4.Two wall switches may be used to activate the two receptacle plugs independently.

Note: Wiring to the Junction Box should be run through the 7/8" diameter access hole located on one of the sides of the fireplace outer wall. A Romex type connector is provided and should be used to protect and restrain the wiring where it passes through the fireplace outer wall. The Junction Box should be positioned in the lower compartment of the fireplace/firebox so that it does not interfere with moving parts of the blower assembly. The Junction Box incorporates magnets on the bottom side to retain and reduce the chance of movement or vibration during blower operation.

Note: If only the blower option is to be installed, wiring may be performed as described and illustrated in the following Blower Installation section.

26670-0-0110

Page 25

Image 25
Contents Premium Vent-Free Multi-Sided Fireplaces Table of Contents Hardware Package Carton ContentsDo not Tamper with Pilot Light Safety Important Safety InformationLP-GAS Warning Odor Safety Information for Users of LP-GASIntroduction Overall Dimensions SpecificationsAccessories ModelUnusually Tight Construction Water Vapor a BY-PRODUCT of Unvented Room HeatersOutdoors Ventilation Air From Inside BuildingVentilation Air Ventilation Air From Inside Building Figure Ventilation Air From Outdoors FigureGAS Supply Installing a New Main Gas CockChecking Manifold Pressure See Figure ClearancesMantel Clearances with Standard Hood Combustible MaterialsFireplace Installation Instructions Planning InstallationPremium Vent-Free Fireplace Framing Dimensions Inches Fireplace FramingFireplace Dimensions Fireplace Installation InstructionsLocating Fireplace Hood Installation Installing HoodsExtended Hoods FinishingGAS Line Connection Placing Lava Rock in Front of Burner on Fireplace Floor Placement of Glowing Embers and Lava RockAll Logs Operation INSTRUCTIONS/FLAME AppearanceMillivolt Valve lighting instructions Burner Instructions Incorrect Pilot Flame Pattern Pilot Flame CharacteristicsCheck 750 Millivolt System Operation WiringRemote Receiver Heater produces a whistling noise when main burner is lit Gas odor even when control knob is in OFF positionAppliance produces unwanted odors Appliance shuts off during use. Pilot stays onDual Switch Electrical Wiring to Fireplace Receptacle Wiring Optional FBB5 Blower Installation InstructionsOptional Blower Installation Instructions Blower Wheels Blower MotorMaintenance LK2 Accent Light AccessoryVALVE, NAT Parts ListVenturi Gasket HOW to Order Repair PartsSEE-THROUGH Fireplace Parts View Peninsula Fireplace Parts View Variable Speed Control Kit AccessoriesFrame Kits Bottom Trim StripExtended 4 Hoods Accessory Description Model Numbers Accent Light KitLouvers Decorative Door KitsService Notes Empire Premium Vent-Free Fireplaces Empire Comfort Systems

VFP36PP32EP-2, VFP36SP32EP-2, VFP36SP32EN-2, VFP36PP32EN-2 specifications

Empire Comfort Systems offers a range of high-quality vent-free fireplaces, including the models VFP36SP32EN-2, VFP36SP32EP-2, VFP36PP32EP-2, and VFP36PP32EN-2. These models are engineered to provide both warmth and elegance, making them an exceptional choice for enhancing the ambiance of any living space.

One of the key features of these vent-free fireplaces is their impressive heating efficiency. They are designed to provide an optimal heat output without the need for a traditional flue or venting system, allowing homeowners to enjoy a cozy atmosphere without the associated installation and maintenance costs. With their high-efficiency gas burning systems, these fireplaces convert a significant portion of their fuel into heat, resulting in less energy waste and lower utility bills.

The VFP models are equipped with state-of-the-art flame technology, which produces realistic and visually appealing flames that mimic the beauty of a traditional wood-burning fire. The flame appearance can enhance any room’s aesthetics, creating a warm and inviting atmosphere that is perfect for gatherings or quiet evenings at home.

Another notable characteristic is the variety of styles available. The VFP36PP models feature a more modern, contemporary design, while the VFP36SP models have a traditional aesthetic that fits well with classic décor. This versatility in style allows homeowners to select a model that best suits their interior design preferences.

Safety is also a top priority with these fireplaces. They come with built-in safety features, including an automatic shut-off system that activates if the pilot light goes out, ensuring peace of mind for users. The models are also equipped with thermostat controls, allowing for easy temperature adjustments to maintain a comfortable environment.

In terms of fuel options, these vent-free fireplaces can operate on both natural gas and propane, providing flexibility based on the needs and availability of fuel sources. Moreover, they have a compact design, making them an excellent choice for smaller spaces or homes where traditional fireplaces may not be feasible.

In summary, Empire Comfort Systems' VFP36SP32EN-2, VFP36SP32EP-2, VFP36PP32EP-2, and VFP36PP32EN-2 models stand out for their efficiency, aesthetic appeal, safety features, and versatility. These vent-free fireplaces are an exceptional addition to any home, offering warmth and style with the convenience of easy installation and operation.