Dimplex Dimplex DFI2309 Operation, Electric Fireplace Manual Control, Remote Controls

Page 3

Operation

Electric Fireplace Manual Control

The manual controls for the unit are located in the top, right corner, on the front of the firebox (Figure 1). A switch is in the On position when the side with the “ I ”, or “ II ” markings on it is pushed in.

Figure 1

D

C

A

D

C

B

 

 

 

 

 

or

 

 

Heat Switches (all models, all MOD levels)

Figure 1-C - Low Heat Switch (“ I ”)

The Low Heat On/Off Switch supplies power to the heater fan and the heater element. When the switch is in the On (“ I ”) position the heater operates on Low.

Figure 1-D - High Heat Switch (“ II ”)

The High Heat Switch supplies power to the heater fan and the heater element, when the switch is in the On (“ II ”) position the heater operates on High. The C - Low Heat Switch must also be in the On position for the high heat setting to operate.

!NOTE: If Switches C and D are in the Off position, only the flame effect will turn on when the power switch is activated.

Main Power Switches (Figure 1-A & B)

A - On/Off Switch

Used in:

DFI2309 MODs ~ to B

DFI2310 MOD ~

The two (2) position On/Off Switch supplies power to all the fireplace functions.

B - On/Off/On Switch

Used in:

DFI2309 MODs C to D

DFI2310 MODs A to D

This three (3) position switch offers the following functions:

(I)Manual mode

When in the “ I ” position, the fireplace bypasses the built- in remote control, the flame effect is turned on and the electrical supply to the heater is controlled manually using the Low Heat and High Heat Switches (Figure 1-C and D).

(II) Remote mode

The “ II ” position is for operating the unit with the provided remote control. When in “ II ” position the unit is operated with the ON and OFF buttons of the remote control.

!NOTE: Remote control operates main power supply. Heat must still be controlled by switches on fireplace.

(O) Off position

All power to all functions are switched off.

Resetting the Temperature Cutoff Switch

Should the fireplace overheat, an automatic cut out will turn the heater off and it will not come back on without being reset. It can be reset by switching the Main Power Switch (Figure 1-A or B) to the Off (“ O ”) position, and waiting five

(5) minutes before switching the unit back on.

CAUTION: If you need to continuously reset the heater, unplug the unit and call Dimplex North America Limited at 1-888-346-7539 for technical support.

Remote Controls

The following plug-in remote control (Figure 2) is included with the models and MOD levels specified below:

Used in:

 

• DFI2309 MODs ~ to B

 

DFI2310 MOD ~

 

 

Figure 2

 

 

On button

 

 

Off button

OPEN

 

 

 

 

Battery

 

 

cover

 

 

Frequency

 

Plug-in

 

 

receiver

Receiver outlet

 

 

3

Image 3
Contents Insert Model Numbers DFI2309 MOD ~ to D DFI2310 MOD ~ to D Table Of Contents Electric Fireplace Manual Control Resetting the Temperature Cutoff SwitchRemote Controls OperationRemote Control Installation Battery Installation/ReplacementRemote Initialization Exploded Parts Diagram Non-Universal Replacement Parts Replacement Parts ListWiring Diagram DFI2309 MOD ~ to B Wiring Diagram DFI2309 MOD C to D Wiring Diagram DFI2310 MOD ~ Wiring Diagram DFI2310 MOD a to D Mirror Replacement Switch ReplacementReplacement Procedure Heater Assembly/Cutout Replacement Cutout ReplacementHeater Assembly Replacement Power Cord Replacement Light Bulb Requirements Light Bulb ReplacementReplacement Procedure for DFI2309 & DFI2310 MODs ~ to C Helpful HintsReplacement Procedure for DFI2309 & DFI2310 MODs D Flicker Motor/Flicker Rod ReplacementRemote Receiver Board Replacement DFI2309/2310 MODs C to D Light Harness Replacement Log Driver Board Replacement DFI2310 only all MODs Log Driver