Operation
Electric Fireplace Manual Control
The manual controls for the unit are located in the top, right corner, on the front of the firebox (Figure 1). A switch is in the On position when the side with the “ I ”, or “ II ” markings on it is pushed in.
Figure 1 | D | C | A | D | C | B |
| ||||||
|
|
|
| or |
|
|
Heat Switches (all models, all MOD levels)
Figure 1-C - Low Heat Switch (“ I ”)
The Low Heat On/Off Switch supplies power to the heater fan and the heater element. When the switch is in the On (“ I ”) position the heater operates on Low.
Figure 1-D - High Heat Switch (“ II ”)
The High Heat Switch supplies power to the heater fan and the heater element, when the switch is in the On (“ II ”) position the heater operates on High. The C - Low Heat Switch must also be in the On position for the high heat setting to operate.
!NOTE: If Switches C and D are in the Off position, only the flame effect will turn on when the power switch is activated.
Main Power Switches (Figure 1-A & B)
A - On/Off Switch
Used in:
•DFI2309 MODs ~ to B
•DFI2310 MOD ~
The two (2) position On/Off Switch supplies power to all the fireplace functions.
B - On/Off/On Switch
Used in:
•DFI2309 MODs C to D
•DFI2310 MODs A to D
This three (3) position switch offers the following functions:
(I)Manual mode
When in the “ I ” position, the fireplace bypasses the built- in remote control, the flame effect is turned on and the electrical supply to the heater is controlled manually using the Low Heat and High Heat Switches (Figure
(II) Remote mode
The “ II ” position is for operating the unit with the provided remote control. When in “ II ” position the unit is operated with the ON and OFF buttons of the remote control.
!NOTE: Remote control operates main power supply. Heat must still be controlled by switches on fireplace.
(O) Off position
All power to all functions are switched off.
Resetting the Temperature Cutoff Switch
Should the fireplace overheat, an automatic cut out will turn the heater off and it will not come back on without being reset. It can be reset by switching the Main Power Switch (Figure
(5) minutes before switching the unit back on.
CAUTION: If you need to continuously reset the heater, unplug the unit and call Dimplex North America Limited at
Remote Controls
The following
Used in: |
| |
• DFI2309 MODs ~ to B |
| |
• | DFI2310 MOD ~ |
|
| Figure 2 |
|
| On button |
|
| Off button | OPEN |
|
| |
|
| Battery |
|
| cover |
|
| Frequency |
|
| |
| receiver | Receiver outlet |
|
|
3