Thank you for choosing this Valor gas fire. It has been designed to give years of
PLEASE OBSERVE THE CAUTION STATEMENTS ON PAGE 1
1. GENERAL SPECIFICATION
The fire has a maximum gas input of 4.9kW.
The overall dimensions are shown in Figure 1.
2. OPERATION
2.1 The pilot may be left alight. It is advisable, however, that the pilot is turned off if the premises are to be left unoccupied for a lengthy period.
2.2 For your safety the fire is fitted with a Flame Supervision Device which will shut off the gas supply if for any reason the pilot goes out. This device incorporates a fixed probe which senses the heat from the pilot flame. If the probe is cool the device will prevent any gas flow unless the control knob is held down. (see the following lighting instructions).
2.3 To light the pilot
Warning: If the pilot flame is extinguished either intentionally or unintentionally, do not attempt to relight the gas until at least 3 minutes have elapsed.
2.3.1 Depress the control knob. While keeping it depressed, turn to IGN position. Turning the control should normally cause two consecutive sparks to occur which should ignite the pilot gas. A click should be heard while turning each time a spark is generated. The pilot flame can be seen by looking through the gap at the front of the right side front coal - see figure 3.
2.3.2 When the pilot is alight, keep the control knob depressed for a few seconds to prevent the flame supervision device from shutting off the gas supply while its probe warms up, as explained above, then release it. If the pilot does not remain alight turn the knob back to OFF, wait a few seconds and repeat the lighting sequence.
2.4 To select burner setting.
When the pilot is alight, partially depress the knob and turn to position 1.
Both main and decorative flame burners should light at their lowest setting.
The decorative flames should just be visible.