Weber SUMMIT manual Check for GAS Leaks Remove Control Panel

Page 8

8

GAS INSTRUCTIONS

 

CHECK FOR GAS LEAKS

WARNING : The gas connections of your Summit® gas grill have been factory tested. We do however recommend that you leak check all gas connections before operating your Summit® gas grill.

REMOVE CONTROL PANEL

Part required: Phillips Screwdriver.

Remove the burner control knobs (1). The screws (2) need to be removed from the control panel (3) before the control panel is removed from the grill.

Put your fi ngers under the front edge of the control panel and lift off. Completely remove the control panel (4) from the cooking box assembly exposing the valves, burners, igniter, and manifold.

Remove the Front Panel by sliding the panel up and out of the slots.

CHECK FOR GAS LEAKS

DANGER

Do not use an open flame to check for gas leaks. Be sure there are no sparks or open flames in the area while you check for leaks. Sparks or open flames will result in a fire or explosion which can cause serious bodily injury or death and damage to property.

WARNING: You should check for gas leaks every time you disconnect and reconnect a gas fitting.

Note - All factory-made connections have been thoroughly checked for gas leaks. The burners have been flame-tested. As a safety precaution however, you should recheck all fittings for leaks before using your Weber® gas barbecue. Shipping and handling may loosen or damage a gas fitting.

WARNING: Perform these leak checks even if your barbecue was dealer or store assembled.

You will need: a soap and water solution, and a rag or brush to apply it. Make sure side burner is OFF (See LEAK CHECK PREPARATION). Remove valve control knob and screws. Remove porcelain top.

To perform leak checks: Slide back the collar of the quick disconnect. Push male fi tting of the hose into the quick disconnect, and maintain pressure. Slide the collar closed. If it does not engage or lock, repeat procedure. Gas will not fl ow unless the quick disconnect is properly engaged.

Turn on gas supply.

Check for leaks by wetting the connections with the soap and water solution and watching for bubbles. If bubbles form or if a bubble grows, there is a leak.

Note - Since some leak test solutions, including soap and water, may be slightly corrosive, all connections should be rinsed with water after checking for leaks.

WARNING: Do not ignite burners when leak checking.

(1 )

(2 )

(3 )

(2

(4 )

Image 8
Contents Summit GAS Grill NG US EnglishLiquid Propane GAS Units only For replacement parts call WarrantyCustomer Service Center Roselle Road, Suite Schaumburg, IL For Installation in Canada Gas Supply TestingGeneral Instructions OperatingGrilling Methods Cleaning Install GAS Supply Leak Check PreparationGeneral Specifications for Piping Gas Line PipingCheck for Gas Leaks GAS InstructionsConnect GAS Supply Check for GAS Leaks Remove Control Panel Check for GAS LeaksSummit a Reinstall Control Panel Grilling MethodsPreheating Covered cookingIndirect Cooking Operating InstructionsDirect Cooking Crossover Ignition System Grilling Tips & Helpful HintsLighting To Extinguish Manual LightingSide Burner Lighting Instructions Lighting with IgniterLighting only the side burner Lighting the side burner if the main burners are litSummit B, Cc, D Manually Lighting Side Burner Manual LightingTo use the smoker Using the SmokerCleaning the smoker Lighting the Smoker Burner Manually Lighting the Smoker Burner Rotisserie Assembly Install the motor bracketAttach the motor Put the spit forks on the rotisserie shaftUsing the Rotisserie Important Safeguards CookingLighting the Rotisserie Burner To Extinguish Manually Lighting the Rotisserie Burner Operating Instructions Problem Check Cure Side Burner Troubleshooting Side Burner MaintenanceRotisserie Troubleshooting Burner does not lightWeber Spider /INSECT Screens MaintenanceInspection and cleaning of the Spider/Insect screens Main Burner Cleaning Procedure Main Burner Flame PatternReplace Main Burners Turn off the gas supplyMaintenance BB Crossover Ignition System Operations Replace Igniter Batteries
Related manuals
Manual 2 pages 24.52 Kb