Weber FLAME manual Operating Instructions, Remove rain shields

Page 17

 

OPERATING INSTRUCTIONS

17

MANUAL LIGHTING

 

 

 

 

1)

Remove rain shields.

1.

 

 

 

 

 

 

 

 

 

DANGER

 

 

 

 

Failure to remove rain shields while igniting the

 

 

 

 

fireplace’s burners, or not waiting 5 minutes to allow

 

 

 

 

the gas to clear if the fireplace does not light, may

 

 

4.

6.

result in an explosive flame-up which can cause

 

 

 

 

 

 

serious bodily injury or death.

 

 

 

 

2) Make sure the burner control knob is turned OFF. (Push control knob

2.

5.

 

 

 

 

 

 

 

down and turn clockwise to ensure that it is in the OFF position.)

 

 

 

 

3) Turn the gas supply valve on.

 

 

 

 

 

WARNING: Do not lean over the open fireplace. Keep

 

 

 

 

 

your face and body at least one foot away from the

 

 

 

 

 

logs when lighting the fireplace.

 

 

 

 

4) Insert match holder with lit match near the center of the burner area.

 

 

 

 

5) Push in igniter several times, until burner is lit.

 

 

 

 

6) Check that the burner is lit.

 

 

 

 

 

WARNING: If the burner does not light, turn the

 

 

 

 

 

burner control knob to OFF and wait 5 minutes to let

 

 

 

 

 

the gas clear before you try again or try to light with a

 

 

 

 

 

match.

 

 

 

3.

 

 

 

 

 

Note: Normal burning pattern will develop light soot on log set. If heavy

 

 

 

 

 

sooting occurs, refer to troubleshooting.

 

 

 

 

TO EXTINGUISH

Push in the burner control knob and turn clockwise to the OFF posi- tion. Turn gas supply OFF at the source. When unit has cooled, replace rain shields.

Image 17
Contents Weber Flametm Page For replacement parts call Warranty / General InstructionsCustomer Service Center Roselle Road, Suite Schaumburg, IL Cleaning For Installation in CanadaGeneral Instructions Operating Storage AND/OR NON USEParts List Exploded View Exploded View List Assembly Assembly Wrench tighten ALL nuts at this time Assembly General Specifications for Piping Install GAS SupplyGas Line Piping Test ConnectionsCheck That the Burner Valve is OFF GAS InstructionsConnect GAS Supply To connect gas hose at the Fireplace Slide back the collarCheck for GAS Leaks Quick disconnect-to-supply connection Check Bulkhead fi tting-to-Regulator connection100 125 150 175 200 364 493 622 132 824 278 190 152 130To Extinguish Operating InstructionsLighting Remove rain shields Operating InstructionsProblem Check Cure TroubleshootingAnnual Maintenance MaintenanceMain Burner Cleaning Procedure Weber Spider / Insect ScreenIgnition System Main Burner Flame Pattern