Breckwell P23I, P23FSA, P23FSL owner manual Stove Shuts OFF and the # 3 Light Flashes

Page 24

24

TROUBLESHOOTING GUIDE

STOVE SHUTS OFF AND THE # 3 LIGHT FLASHES

Possible Causes:

Possible Remedies: (Unplug stove first when possible)

 

 

 

1.

The hopper is out of pellets.

Refill the hopper.

 

 

 

2.

The air damper is too far open for a low feed setting.

If burning on the low setting, you may need to close the damper all

 

 

the way (push the knob in so it touches the side of the stove).

 

 

 

3.

The burnpot is not pushed completely to the rear of the firebox.

Make sure that the air intake collar on the burnpot is touching the

 

 

rear wall of the firebox.

 

 

 

4.

The burnpot holes are blocked.

Remove the burnpot and thoroughly clean it.

 

 

 

5.

The air inlet, the interior chambers, or exhaust system has a

Follow all cleaning procedures in the maintenance section of the

 

partial blockage.

owner’s manual.

 

 

 

6.

The auger shaft is jammed.

Start by emptying the hopper. Then remove the auger motor by

 

 

removing the auger pin. Remove the auger shaft inspection plate in

 

 

the hopper so that you can see the auger shaft. Gently lift the auger

 

 

shaft straight up so that the end of the auger shaft comes up out of

 

 

the bottom auger bushing. Next, remove the two nuts that hold the

 

 

top auger biscuit in. Then rotate the bottom end of the auger shaft

 

 

up towards you until you can lift the shaft out of the stove. After you

 

 

have removed the shaft, inspect it for bent flights, burrs, or broken

 

 

welds. Remove any foreign material that might have caused the

 

 

jam. Also, check the auger tube for signs of damage such as burrs,

 

 

rough spots, or grooves cut into the metal that could have caused a

 

 

jam.

 

 

 

7.

The auger motor has failed.

Remove the auger motor from the auger shaft and try to run the unit.

 

 

If the motor will turn the shaft is jammed on something. If the motor

 

 

will not turn, the motor is bad.

 

 

 

8.

The Proof of Fire (POF) thermodisk has malfunctioned.

Temporarily bypass the POF thermodisk by disconnecting the two

 

 

brown wires and connecting them with a short piece of wire. Then

 

 

plug the stove back in. If the stove comes on and works, you need

 

 

to replace the POF thermodisk. This is for testing only. DO NOT

 

 

LEAVE THE THERMODISC BYPASSED. Your blowers will never

 

 

shut off and if the fire went out the auger will continue to feed pellets

 

 

until the hopper is empty if you leave the POF thermodisk bypassed.

 

 

 

9.

The high limit thermodisk has tripped or is defective.

Using the owner’s manual, locate the high limit thermodisk. There is

 

 

a red button located on the back of it. Press the red button. If you

 

 

hear a click, the high limit had tripped. The stove should now

 

 

function normally. To test if the thermodisk is bad, you can bypass it

 

 

as described previously for the POF thermodisk.

 

 

 

10.

The F2 fuse on the control board has blown.

Remove the control board. On the back there are two fuses. The

 

 

one closer to the edge is the F2 fuse. If it appears to be bad,

 

 

replace it with a 5 Amp 250 Volt fuse. Plug the stove back in and try

 

 

to run the unit.

 

 

11. The control board is not sending power to the POF thermodisk

There should be a 5-volt (approximately) current going to the POF

 

or other auger system components.

thermodisk after the stove has been on for 10 minutes.

 

 

 

Image 24
Contents Tradition Series P23 Introduction Important InformationSafety Precautions Table of Contents Installation SpecificationsPreparation ClearancesWhen Outside AIR is not Used Combustion AIR SupplyVenting Sources of Outside Combustion AirFreestanding Installations Assembling Pedestal or LEG SET Equivalent Vent Length EVLHorizontally Through Wall refer to Figure Vertically with NEW Chimney System Refer to Figure Vertically Into Existing Chimney SystemInstallation Through Side of Masonry Chimney Vertically Into Existing Masonry FireplaceInsert Installations Assembling the Flashing SETWhen Vent Pipe Extends to Chimney TOP Refer to Figures 16 When Vent Pipe Extends Through Chimney Blanking PlateChase dimensions shown are minimums and must be maintained AS a BUILT-IN FireplaceElectrical Installation Special Mobile Home Requirements Installation in to a Factory Built Metal FireplaceOperation Proper FuelPRE-START-UP Check Building a FireOpening Door Room AIR FANRE-STARTING a Warm Stove Breckwell Maintenance Tool Shutdown ProcedureSafety Features If Stove Runs OUT of PelletsThermostat Installation Thermostat InstallationOptional Thermostat Please Read this Maintenance ASH RemovalASH Disposal Freestanding Models ASH Disposal InsertCleaning Vacuum USEBlowers Chimney Cleaning Daily Weekly Bi-Annually Annually or per TonTroubleshooting Guide Stove Shuts OFF and the # 2 Light FlashesPossible Causes Stove Shuts OFF and the # 3 Light Flashes Stove Feeds PELLETS, but will not Ignite Possible Causes Possible RemediesSmoke Smell Coming Back Into the Home Convection Blower Shuts OFF and Comes Back onFuel feed light is on, you have a bad control board Troubleshooting Guide High Limit Switch Keeps Tripping Heat Level Setting P23Smoke Smell or Soot BUILD-UP Digital Circuit Board Timing RatesElectrical Diagram Replacement Parts P23-PNEW
Related manuals
Manual 30 pages 36.5 Kb Manual 31 pages 7.81 Kb

P23FSL, P23FSA, P23I specifications

The Breckwell P23 series pellet stoves, comprising the P23FSA, P23I, and P23FSL models, are designed to provide efficient heating solutions while maintaining ease of use and aesthetic appeal. These stoves incorporate advanced technology features that set them apart in the modern heating market.

The Breckwell P23FSA model features a traditional freestanding design that blends seamlessly with any home decor. This model is equipped with a large viewing window, allowing users to enjoy the mesmerizing flames while benefiting from its high-efficiency heating capabilities. With a heating capacity of up to 2,000 square feet, it is an ideal choice for larger spaces. The P23FSA uses a digital control board that regulates the feed rate and blower settings, ensuring a consistent and reliable heat output. Additionally, it has a self-diagnostic system that alerts users to any operational issues, making maintenance straightforward.

The P23I, on the other hand, is designed for those seeking a built-in option. This insert offers the same heating capacity as its freestanding counterpart but is specifically made to fit into existing fireplaces, combining functionality with elegance. The P23I boasts a sleek design that enhances any room, while its adjustable blower ensures optimal heat distribution. The insert is also compatible with an optional wall thermostat, providing convenience and enhanced control over the heating schedule.

Lastly, the P23FSL model features a contemporary look with sleek lines and a compact design, ideal for smaller spaces without compromising on heating efficiency. This model includes a large hopper capable of holding up to 50 pounds of pellets, allowing for extended burn times and reduced refueling frequency. The P23FSL also incorporates a user-friendly control panel, providing adjustments at the touch of a button. Like the other models, it prioritizes efficiency, with a low emissions output that aligns with modern environmental standards.

All three models are built with high-quality materials to ensure durability and longevity. They utilize a pellet-burning process that significantly reduces environmental impact compared to traditional wood stoves, making them an eco-friendly heating option. With their combination of technology, efficiency, and aesthetic appeal, the Breckwell P23 series stands out as a top choice for homeowners looking for reliable and stylish heating solutions.