Breckwell P23FSA, P23I, P23FSL owner manual Vertically Into Existing Masonry Fireplace

Page 10

10

INSTALLATION

D.VERTICALLY INTO EXISTING MASONRY FIREPLACE

NOTE: Follow L-Vent chimney manufacturer’s instructions.

1.Have the masonry chimney inspected by a qualified chimney sweep or installer to determine its structural condition.

2.You will need a pipe length equal to the chimney height from the hearth. If outside combustion air is to be used, you will need a pipe length equal to the chimney height plus 18 inches.

3.Install a blanking plate and the chimney pipe, and if used the outside air pipe, as shown in Figure 12.

4.Attach the DuraVent adapter, a section of pipe and clean out tee, making sure the clean out tee is centered in the chimney flue area. Use RTV, metallic tape, and a minimum of three self-taping screws at all joint connections to ensure a tight seal.

5.Position the stove, adhering to the clearances in Figures 1 & 2.

6.Measure and build chimney top plate. Cut out holes for chimney pipe, and if used the outside air pipe. Install and seal with non-hardening mastic to prevent water leakage. Install vent cap.

E.INSTALLATION THROUGH SIDE OF MASONRY CHIMNEY

NOTE: Follow L-Vent chimney manufacturer’s instructions.

1.Position the stove, adhering to the clearances in Figures 1 & 2. Mark the center of the hole where the pipe is to pierce the masonry chimney.

2.It will be necessary to break out the masonry around the location of the pipe center mark. Use a 4-inch diameter hole for 3-inch pipe and 5-inch diameter hole for 4-inch pipe.

3.Measure and build chimney top plate. Cut out holes for chimney pipe, and if used the outside air pipe.

4.Install the tee on the bottom of the vertical pipe system and lower it down the chimney until the center branch of the tee is level with the center of the hole in the masonry, as shown in Figure 13.

5.Install and seal the top plate from step 3 with non- hardening mastic. Slip the storm collar over the pipe, and while holding the pipe at the proper elevation, affix the collar with a minimum of three ¼” stainless steel sheet metal screws. Seal all joints and seams around the collar.

6.Connect the horizontal pipe by pushing it through the hole in the masonry and lining it up with the branch in the tee. Push the pipe into the tee while twisting it to lock it into the tee.

7.If desired, once the horizontal pipe is in place, the space between the pipe and masonry may be filled with high-temperature grout.

8.Install the trim collar. An adjustable pipe length and adapter may be needed to finish the connection to the stove.

FIGURE 12

FIGURE 13

Image 10
Contents Tradition Series P23 Introduction Important InformationSafety Precautions Table of Contents Preparation InstallationSpecifications ClearancesVenting When Outside AIR is not UsedCombustion AIR Supply Sources of Outside Combustion AirFreestanding Installations Assembling Pedestal or LEG SET Equivalent Vent Length EVLHorizontally Through Wall refer to Figure Vertically with NEW Chimney System Refer to Figure Vertically Into Existing Chimney SystemInstallation Through Side of Masonry Chimney Vertically Into Existing Masonry FireplaceInsert Installations Assembling the Flashing SETWhen Vent Pipe Extends to Chimney TOP Refer to Figures 16 When Vent Pipe Extends Through Chimney Blanking PlateChase dimensions shown are minimums and must be maintained AS a BUILT-IN FireplaceElectrical Installation Special Mobile Home Requirements Installation in to a Factory Built Metal FireplacePRE-START-UP Check OperationProper Fuel Building a FireRoom AIR FAN Opening DoorRE-STARTING a Warm Stove Safety Features Breckwell Maintenance ToolShutdown Procedure If Stove Runs OUT of PelletsThermostat Installation Thermostat InstallationOptional Thermostat Please Read this ASH Disposal Freestanding Models MaintenanceASH Removal ASH Disposal InsertVacuum USE CleaningBlowers Chimney Cleaning Daily Weekly Bi-Annually Annually or per TonStove Shuts OFF and the # 2 Light Flashes Troubleshooting GuidePossible Causes Stove Shuts OFF and the # 3 Light Flashes Smoke Smell Coming Back Into the Home Stove Feeds PELLETS, but will not IgnitePossible Causes Possible Remedies Convection Blower Shuts OFF and Comes Back onFuel feed light is on, you have a bad control board Troubleshooting Guide Smoke Smell or Soot BUILD-UP High Limit Switch Keeps TrippingHeat Level Setting P23 Digital Circuit Board Timing RatesElectrical Diagram Replacement Parts P23-PNEW
Related manuals
Manual 30 pages 36.5 Kb Manual 31 pages 7.81 Kb

P23FSL, P23FSA, P23I specifications

The Breckwell P23 series pellet stoves, comprising the P23FSA, P23I, and P23FSL models, are designed to provide efficient heating solutions while maintaining ease of use and aesthetic appeal. These stoves incorporate advanced technology features that set them apart in the modern heating market.

The Breckwell P23FSA model features a traditional freestanding design that blends seamlessly with any home decor. This model is equipped with a large viewing window, allowing users to enjoy the mesmerizing flames while benefiting from its high-efficiency heating capabilities. With a heating capacity of up to 2,000 square feet, it is an ideal choice for larger spaces. The P23FSA uses a digital control board that regulates the feed rate and blower settings, ensuring a consistent and reliable heat output. Additionally, it has a self-diagnostic system that alerts users to any operational issues, making maintenance straightforward.

The P23I, on the other hand, is designed for those seeking a built-in option. This insert offers the same heating capacity as its freestanding counterpart but is specifically made to fit into existing fireplaces, combining functionality with elegance. The P23I boasts a sleek design that enhances any room, while its adjustable blower ensures optimal heat distribution. The insert is also compatible with an optional wall thermostat, providing convenience and enhanced control over the heating schedule.

Lastly, the P23FSL model features a contemporary look with sleek lines and a compact design, ideal for smaller spaces without compromising on heating efficiency. This model includes a large hopper capable of holding up to 50 pounds of pellets, allowing for extended burn times and reduced refueling frequency. The P23FSL also incorporates a user-friendly control panel, providing adjustments at the touch of a button. Like the other models, it prioritizes efficiency, with a low emissions output that aligns with modern environmental standards.

All three models are built with high-quality materials to ensure durability and longevity. They utilize a pellet-burning process that significantly reduces environmental impact compared to traditional wood stoves, making them an eco-friendly heating option. With their combination of technology, efficiency, and aesthetic appeal, the Breckwell P23 series stands out as a top choice for homeowners looking for reliable and stylish heating solutions.