PRECAUTIONS

Note: These fireplace systems are not difficult to install. However, in the interest of safety, it is recommended that the installer be a quali- fied or certified “tradesman” familiar with com- monly accepted fireplace installation and safety techniques as well as prevailing local codes.

The most important areas of concern dealing with the installation of factory-built fireplaces are clearances to combustible materials, proper assembly of component parts, height of the chimney system, the proper use of accesso- ries supplied by the manufacturer and the techniques employed in using finishing mate- rials applied to the wall surrounding the fire- place, hearth extensions and wall shields. Each of these topics will be covered in thorough detail throughout this manual. Please give each your special attention as you progress with your installation.

IMPORTANT: WHEN INSTALLING IN CANADA, THE CHIMNEY AIR KIT MUST BE INSTALLED PER THE WARNOCK HERSEY INC. LISTING.

IMPORTANT: THE MINIMUM AIR SPACE TO COMBUSTIBLES FOR THE CHIMNEY SYSTEM IS 2" (51 MM).

INTRODUCTION

General Information

This fireplace is a conventional radiant heat fireplace with standard bar grates, optional outside combustion air kits and optional deco- rative glass doors.

Note: Illustrations shown reflect “typical” instal- lations with nominal dimensions and are for design and framing reference only. Actual instal- lations may vary due to individual design prefer- ences. However, always maintain minimum clearances to combustible materials and do not violate any specific installation requirements.

These Elite Series fireplaces have been tested and listed by Warnock Hersey Inc. (Report No. J20054576-231) to U.L. 127 standard for U.S. installations and U.L.C. S610 standard for Cana- dian installations. These units are intended for installation in residential homes and buildings of conventional construction, not in mobile homes.

These fireplace systems are designed for in- stallation in accordance with the National Fire Protection Standard for chimneys, fireplaces and solid fuel burning appliances; NFPA 211 and in accordance with codes such as the BOCA Basic/National Codes, the Standard Me- chanical Code, Uniform Building Codes and/or the Canadian National Code.

WARNING: FAILURE TO USE MANUFAC- TURE PROVIDED PARTS, VARIATIONS IN TECHNIQUES AND CONSTRUCTION MA- TERIALS OR PRACTICES OTHER THAN THOSE DESCRIBED IN THIS MANUAL MAY CREATE A FIRE HAZARD AND VOID THE LIMITED WARRANTY.

When complete these fireplace systems con- sist of five basic “sub-systems”:

1.The Fireplace

2.The Chimney and Termination

3.The Optional Glass Doors

4.The Optional Combustion Air Kit

5.The Chimney Collar Enclosure Kit (Canada Only)

CHIMNEY CLEARANCES AND MANTEL HEIGHT REQUIREMENTS

The fireplace may be placed on or near normal construction materials*. The combustion air kit, firestop spacer and roof flashings (not chase flashings) may be placed directly on or against normal construction materials*. The chimney requires a minimum 2" (51 mm) air space to combustibles. A combustible mantle may be installed a minimum of 12" (305 mm) above the opening of the fireplace as per NFPA 211, Sec- tion 7-2.3.3. In Canada the minimum is 24" (610

TYPICAL INSTALLATION

Chimney

and

Termination

Optional Position

Chimney

 

Air Kit

 

(Canada Only)

Outside Combustion Air Kit (Optional)

Figure 1

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

mm) above the opening.

The fireplace and chimney system must be enclosed when installed in or passing through a living area where combustibles or people may come in contact with it. This is important to prevent possible personal injury or fire hazard.

For questions, please call your distributor or the manufacturer. Special restrictions apply to the front and facing of the fireplace and nearby walls (See pages 16 and 17 ).

CHIMNEY SYSTEM

This fireplace is designed and code listed for use with Security Chimneys FTF10 chimney System only. Always use Security Chimneys FTF10 chimney components with this fire- place. Do not modify or alter these compo- nents as this may cause a potential serious hazard and void the Warranty.

*Construction Materials:

 

• framing materials

• paneling

• particle board

• flooring

• dry wall

• etc.

• plywood

 

3

Image 3
Contents Retain These Instructions For Future Reference Wood Burning Fireplaces 850,045M REV. N/C 01/2007WH Report No. J20054576-231 Table of Contents Chimney Clearances and Mantel Height Requirements Typical InstallationPrecautions IntroductionLocation of Fireplace Assembly OutlineChimney Height Chase EnclosureFireplace Clearances Assembly StepsInstalling the Fireplace PRE-INSTALLATION NotesTop View Fireplace SpecificationsFront View Left SideFTF10 Offset Framing Dimensions 48 ¹¹⁄₁₆ 1237 mmFraming Dimensions for Ceiling Flue Type FTF10For Canadian Installations Proceed with Steps Installing the Chimney SystemNo x ¹⁄₂ screws provided Figure FTF10-S4 Stabilizer For Canada OnlyRoof Pitch Model Flat to 6/12 12 to 12/12508mm Using the FTF10-CTDTM Round TerminationUsing a CT2 Chase Termination TEN-FOOT Rule SummaryMultiple Terminations Special Offset InstructionsFTF10 Chimney Component Calculations 20 Max 6mStabilizer 10 Max Underside of Chimney Offset CalculationsFTF10 Offset Elevation Chart FTF10 Vertical Elevation ChartInstalling Offsets Or CeilingOptional Equipment Considerations GAS Line Connection Cold Climate InsulationFireplace Finishes Hearth Extensions and Wall Shields Value = 1/k = r x thickness of material used RM = rM x TS = 0.05 x 3/4 =RM = rM x TS = 0.20 x 1/2 = West Taft Avenue Orange, California Installation ComponentsFinish to Your Taste Lennox Hearth Products63L16 FTF10-12 63L17 FTF10-18 63L18 FTF10-36 62L94 Orange, CA 850,045M REV. N/C 01/2007

TM-4500 specifications

Lucent Technologies TM-4500 is a highly regarded platform in the world of telecommunications, known for its robust functionality and adaptability in various network environments. As an integral component of Lucent's product lineup, the TM-4500 serves a diverse range of applications, enhancing the capabilities of service providers and businesses alike.

One of the main features of the TM-4500 is its versatile architecture, which supports a variety of communication protocols, including TDM, ATM, and IP. This interoperability allows for seamless integration into existing networks, providing carriers and enterprises the flexibility to upgrade and evolve their systems without incurring excessive costs. This adaptability ensures that clients can customize their solutions to meet specific operational requirements.

Another key characteristic of the TM-4500 is its emphasis on reliability and performance. The platform is designed for high availability, ensuring continuous operation even under demanding conditions. This is crucial for telecommunications networks where downtime can result in significant financial losses and customer dissatisfaction. The TM-4500 incorporates advanced redundancy features that help maintain service integrity, contributing to its reputation as a dependable solution in critical environments.

The TM-4500 also stands out with its powerful processing capabilities and scalability. As networks grow and data traffic increases, the platform can be expanded to accommodate higher bandwidth needs. Its modular design allows operators to add or upgrade components without extensive overhauls, thereby enhancing the lifespan of the investment. This capability is essential for businesses looking to future-proof their communications infrastructure.

In terms of network management, the TM-4500 is equipped with sophisticated monitoring and diagnostic tools. These features enable real-time performance tracking and troubleshooting, assisting operators in maintaining optimal service levels. The platform’s user-friendly interface helps streamline network management tasks, reducing the complexity often associated with large-scale telecommunications operations.

Security is another important aspect of the TM-4500. As cyber threats continue to evolve, the platform includes robust security protocols to safeguard data and ensure secure communications. This is increasingly vital in a landscape where data breaches can have severe repercussions.

In summary, the Lucent Technologies TM-4500 stands out in the telecommunications sphere due to its versatile architecture, reliability, scalability, advanced network management tools, and strong security features. This combination makes it a preferred choice for service providers and enterprises looking to enhance their communications infrastructure.