Lucent Technologies TM-4500 For Canada Only, Roof Pitch Model Flat to 6/12, 12 to 12/12

Page 9

For Canada Only

When installing the chimney system through an open attic space, the attic shield assembly- firestop spacer must be used (Figure 23 ). This installation procedure is Warnock Hersey Inc. listed only for use in Canada.

Open Attic Space

Figure 23

Step 4. Note: Chimney sections are constructed with a unique locking tab design, which en- sures an immediate, tight assembly between sections. Plan your chimney requirements care- fully before assembly as chimney is difficult to disassemble after installation. If disassembled, the tabs might become damaged. Be certain tabs are properly formed to ensure locking tabs engage properly.

Security Chimneys FTF10 chimney system is a two piece chimney, which snap together from the fireplace up. Start with the inner flue section with the lanced end up, snap lock it in to the matching collar on top of the fireplace. At all subsequent joints, the upper flue section fits into the preceding flue section. Each piece snaps together by means of locking tabs (9 locking tabs per joint). Check each piece by pulling up slightly from the top to ensure proper engagement before installing the next section. If the flue has been installed correctly, it will not separate when you test it. Also, the inner flue joint where each section is joined should be tight and flat without gaps (Figure 24 ).

Figure 24

Outer pipe section installs in just the opposite way; the lanced end goes down and each new section goes OVER the outside of the previous section installed (Figure 25 ).

Locking Tabs (Lances)

Figure 25

Note: Assemble one component of chimney at a time (inner section first, then outer section last) before proceeding with the next complete section.

Continue to assemble the chimney up through framed opening. Assemble just enough to pen- etrate the roof flashing openings (Figure 26 ). Always maintain 2" minimum air space to com- bustible materials and always check each chim- ney joint (inner and outer) to ensure proper engagement. Check vertical alignment of chim- ney so that it projects from the roof in true vertical position.

2" (51mm) Min. Air Space to Combustibles

Figure 26

Security's chimney sections do not need to be screwed together. Additional reinforcement is not necessary except in certain offset condi- tions (refer to page 12, Figure 38 ).

Step 5. The height of vertical chimney pipe supported only by the fireplace must not ex- ceed 30'. Chimney heights above 30' must be supported by a Model FTF10-S4 stabilizer in- stalled at 30' intervals.

Note: The Model FTF10-S4 adds 3" net effective height to the total chimney system.

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Install the Model FTF10-S4 stabilizer by fitting inner section down into respective section of proceeding flue pipe and locking outer stabilizer section into place over the outer chimney pipe. Position for proper clearance through framed opening and fasten straps securely (under ten- sion in “shear”) into place on framing. Use 8d nails or equivalent. Attach successive lengths of chimney pipe directly to stabilizer using same techniques as described in Step 4 (Figure 27 ).

FTF10-S4 Stabilizer

Figure 27

Note: Do not apply excessive pressure to any subsequent chimney sections following the sta- bilizer when installing. Ensure each subsequent chimney section is securely attached by testing as noted in Step 4.

Step 6. Select the proper Security Chimneys roof flashing based on pitch of roof. Use chart below for selection:

Roof Pitch

Model

 

 

Flat to 6/12

F10F6

 

 

6/12 to 12/12

F10F12

 

 

Next, slide roof flashing over extended chimney section that previously has been installed above the roof opening in Step 4. FTF10 flashings require flashing spacers. Slide flashing all the way down until the flashing base rests flat on the roof (Figure 28 ). Again, check the vertical position of the chimney and the 2" minimum air space to combustibles.

FTF10 Chimney

Do Not Seal

Flashing Spacers

FTF10 Flashing

Figure 28

Note:Donotcaulkorsealtheventilatingopenings.

9

Image 9
Contents Retain These Instructions For Future Reference Wood Burning Fireplaces 850,045M REV. N/C 01/2007WH Report No. J20054576-231 Table of Contents Precautions Typical InstallationIntroduction Chimney Clearances and Mantel Height RequirementsChimney Height Assembly OutlineChase Enclosure Location of FireplaceInstalling the Fireplace Assembly StepsPRE-INSTALLATION Notes Fireplace ClearancesFront View Fireplace SpecificationsLeft Side Top ViewFraming Dimensions for Ceiling Flue Type Framing Dimensions 48 ¹¹⁄₁₆ 1237 mmFTF10 FTF10 OffsetFor Canadian Installations Proceed with Steps Installing the Chimney SystemNo x ¹⁄₂ screws provided Figure Roof Pitch Model Flat to 6/12 For Canada Only12 to 12/12 FTF10-S4 StabilizerUsing a CT2 Chase Termination Using the FTF10-CTDTM Round TerminationTEN-FOOT Rule Summary 508mmMultiple Terminations Special Offset InstructionsFTF10 Chimney Component Calculations 20 Max 6mStabilizer 10 Max Underside of Chimney Offset CalculationsFTF10 Offset Elevation Chart FTF10 Vertical Elevation ChartInstalling Offsets Or CeilingOptional Equipment Considerations GAS Line Connection Cold Climate InsulationFireplace Finishes Hearth Extensions and Wall Shields Value = 1/k = r x thickness of material used RM = rM x TS = 0.05 x 3/4 =RM = rM x TS = 0.20 x 1/2 = Finish to Your Taste Installation ComponentsLennox Hearth Products West Taft Avenue Orange, California63L16 FTF10-12 63L17 FTF10-18 63L18 FTF10-36 62L94 Orange, CA 850,045M REV. N/C 01/2007

TM-4500 specifications

Lucent Technologies TM-4500 is a highly regarded platform in the world of telecommunications, known for its robust functionality and adaptability in various network environments. As an integral component of Lucent's product lineup, the TM-4500 serves a diverse range of applications, enhancing the capabilities of service providers and businesses alike.

One of the main features of the TM-4500 is its versatile architecture, which supports a variety of communication protocols, including TDM, ATM, and IP. This interoperability allows for seamless integration into existing networks, providing carriers and enterprises the flexibility to upgrade and evolve their systems without incurring excessive costs. This adaptability ensures that clients can customize their solutions to meet specific operational requirements.

Another key characteristic of the TM-4500 is its emphasis on reliability and performance. The platform is designed for high availability, ensuring continuous operation even under demanding conditions. This is crucial for telecommunications networks where downtime can result in significant financial losses and customer dissatisfaction. The TM-4500 incorporates advanced redundancy features that help maintain service integrity, contributing to its reputation as a dependable solution in critical environments.

The TM-4500 also stands out with its powerful processing capabilities and scalability. As networks grow and data traffic increases, the platform can be expanded to accommodate higher bandwidth needs. Its modular design allows operators to add or upgrade components without extensive overhauls, thereby enhancing the lifespan of the investment. This capability is essential for businesses looking to future-proof their communications infrastructure.

In terms of network management, the TM-4500 is equipped with sophisticated monitoring and diagnostic tools. These features enable real-time performance tracking and troubleshooting, assisting operators in maintaining optimal service levels. The platform’s user-friendly interface helps streamline network management tasks, reducing the complexity often associated with large-scale telecommunications operations.

Security is another important aspect of the TM-4500. As cyber threats continue to evolve, the platform includes robust security protocols to safeguard data and ensure secure communications. This is increasingly vital in a landscape where data breaches can have severe repercussions.

In summary, the Lucent Technologies TM-4500 stands out in the telecommunications sphere due to its versatile architecture, reliability, scalability, advanced network management tools, and strong security features. This combination makes it a preferred choice for service providers and enterprises looking to enhance their communications infrastructure.