CLASSIC WOOD STOVE FLOOR PROTECTION
B
A
USA FLOOR PROTECTION |
| Residential “C” Vent | Residential Close Clearance | Mobile Home |
| Alcove | ||||
| Close Clearance |
| ||||||||
Flush Wall Hearth Requirements |
|
|
|
|
|
|
| |||
A | B | A | B | A | B | A |
| B | ||
|
|
| ||||||||
Small F1100 | with AirMate | 36" | 38" | 36" | 37" | 36" | 38" | 36" |
| 38" |
| with Rear Deflector | 36" | 38" | 36" | 37" | 36" | 37" | 36" |
| 37" |
Medium S2400 | with Step Top | 36" | 46" | 36" | 45" | 36" | 45" | 36" |
| 45" |
Medium F2400 | with AirMate | 36" | 46" | 36" | 45" | 36" | 45" | 36" |
| 45" |
| with Rear Deflector | 36" | 46" | 36" | 45" | 36" | 45" | 36" |
| 45" |
Large F3100 | with AirMate | 40" | 43" | 40" | 43" | 40" | 43" | 40" |
| 43" |
| with Rear Deflector | 40" | 43" | 40" | 43" | 40" | 43" |
| Not approved | |
|
|
|
|
|
|
|
|
| for alcove | |
|
|
|
|
|
|
|
|
|
| |
CANADA FLOOR PROTECTION | Residential “C” Vent | Residential Close Clearance | Mobile Home |
| Alcove | |||||
Close Clearance |
| |||||||||
Flush Wall Hearth Requirements |
|
|
|
|
|
|
| |||
A | B | A | B | A | B | A |
| B | ||
|
|
| ||||||||
Small F1100 | with AirMate | 40" | 42" | 40" | 41" | 40" | 42" | 40" |
| 42" |
| with Rear Deflector | 40" | 42" | 40" | 41" | 40" | 41" | 40" |
| 41" |
Medium S2400 | with Step Top | 40" | 50" | 40" | 49" | 40" | 49" | 40" |
| 49" |
Medium F2400 | with AirMate | 40" | 50" | 40" | 49" | 40" | 49" | 40" |
| 49" |
| with Rear Deflector | 40" | 50" | 40" | 49" | 40" | 49" | 40" |
| 49" |
Large F3100 | with AirMate | 44" | 47" | 44" | 47" | 44" | 47" | 44" |
| 47" |
| with Rear Deflector | 44" | 47" | 44" | 47" | 44" | 44" | Not approved for alcove | ||
|
|
|
|
|
|
|
|
|
|
|
B
C
D
A
USA FLOOR PROTECTION |
|
| Residential “C” Vent |
| Residential Close Clearance |
| Mobile Home |
| ||||||
|
|
|
| Close Clearance |
| |||||||||
Corner Hearth Requirements |
|
|
|
|
|
|
|
|
|
|
| |||
A | B | C |
| D | A | B | C | D | A | B | C | D | ||
|
|
| ||||||||||||
Small F1100 | with AirMate | 36" | 52.75" | 45.75" |
| 21.25" | 36" | 47.75" | 40.75" | 16.25" | 36" | 50.75" | 43.75" | 19.25" |
| with Rear Deflector | 36" | 57.25" | 49.25" |
| 25" | 36" | 49.75" | 42.75" | 18.25" | 36" | 58.25" | 50.25" | 26" |
Medium S2400 | with Step Top | 36" | 57.5" | 53.5" |
| 26.5" | 36" | 55" | 52.5" | 24.75" | 36" | 55" | 52.25" | 24.75" |
Medium F2400 | with AirMate | 36" | 57.5" | 53.5" |
| 26.5" | 36" | 55" | 52.5" | 24.75" | 36" | 55" | 52.25" | 24.75" |
| with Rear Deflector | 36" | 58" | 54" |
| 27" | 36" | 57.5" | 53.5" | 27" | 36" | 57.5" | 53.5" | 27" |
Large F3100 | with AirMate | 40" | 60.75" | 53" |
| 24.25" | 40" | 60.75" | 53" | 24.25" | 40" | 60.25" | 54.5" | 24.25" |
| with Rear Deflector | 40" | 63.5" | 53.5" |
| 26.25" | 40" | 60.75" | 53" | 24.25" | 40" | 63" | 54.5" | 24.25" |
Corner Installations
If the rear clearance to combustibles is less than 6", for corner installations the corners may be angled to take advantage of the closer clearances.
6"
6"
CANADA FLOOR PROTECTION |
| Residential “C” Vent |
| Residential Close Clearance |
| Mobile Home |
| |||||||
|
|
| Close Clearance |
| ||||||||||
Corner Hearth Requirements |
|
|
|
|
|
|
|
|
|
|
| |||
A | B | C |
| D | A | B | C | D | A | B | C | D | ||
|
|
| ||||||||||||
Small F1100 | with AirMate | 40" | 54.75" | 47.75" |
| 19.25" | 40" | 49.75" | 42.75" | 14.25" | 40" | 52.75" | 45.75" | 17.25" |
| with Rear Deflector | 40" | 59.25" | 51.25" |
| 23" | 40" | 51.75" | 44.75" | 16.25" | 40" | 60.25" | 52.25" | 24" |
Medium S2400 | with Step Top | 40" | 59.5" | 55.5" |
| 28.5" | 40" | 57" | 54.5" | 26.75" | 40" | 57" | 54.25" | 26.75" |
Medium F2400 | with AirMate | 40" | 59.5" | 55.5" |
| 28.5" | 40" | 57" | 54.5" | 26.75" | 40" | 57" | 54.25" | 26.75" |
| with Rear Deflector | 40" | 60" | 56" |
| 29" | 40" | 59.5" | 55.5" | 29" | 40" | 59.5" | 55.5" | 29" |
Large F3100 | with AirMate | 44" | 62.75" | 55" |
| 22.25" | 44" | 62.75" | 55" | 22.25" | 44" | 62.25" | 56.5" | 22.25" |
| with Rear Deflector | 44" | 65.5" | 55.5" |
| 24.25" | 44" | 62.75" | 55" | 22.25" | 44" | 65" | 56.5" | 22.25" |
Floor Protection
A combustible floor must be protected by
When installed with horizontal venting,
21