INSTALLATION
MASONRY AND FACTORY BUILT FIREPLACE CLEARANCES
The minimum required clearances to combustible materials when installed into a masonry or factory built fi replace are listed below.
| Adjacent | Mantle** | Top | Side | Minimum | Minimum | Minimum |
Unit | Side Wall | (to Top) | Facing | Facing | Hearth | Hearth | Hearth Side |
| (to Side) |
| (to Top) | (to Side) | Extension* | Thickness* | Extension |
| A | B | C | D | E | F | G |
Medium Flush |
|
|
|
|
|
|
|
Insert (I2400) | 11"/280mm | 20"/508mm | 12"/305mm | 8"/200mm | 18"/455mm | 0.5"/13mm | 8"/200mm |
|
|
|
|
|
|
|
|
Side and Top facing is a maximum of 1.5" thick. Floor protection must be
*Hearth thickness of 0.5" with k value = 0.84", R value = 6 or greater.
**
**Max. mantle depth is 10" (254mm).
Thermal fl oor protection is not required if the unit is raised 3.5" minimum (measured from the bottom of the stove). However, standard ember fl oor protec- tion is required. It will need to be a
If the unit is not raised, thermal fl oor protection required is 18" (450 mm) in the US and Canada.
All fl oor protection must be
Clearance diagram for Installations
Minimum Hearth Extension for the front
(E)and sides (G) are measured from the fuel door opening.
HOW TO DETERMINE IF ALTERNATE
FLOOR PROTECTION MATERIALS ARE ACCEPTABLE
|
| DEFINITIONS |
|
|
| |
The specifi ed floor protector should be 3/8" | Step (b): | Thermal Conductance: |
| |||
(18mm) thick material with a K - factor of | Calculate R of proposed system. |
| ||||
|
|
|
|
| ||
0.84. | 4" brick of C = 1.25, therefore | C | = | Btu | = | W |
| Rbrick = 1/C = 1/1.25 = 0.80 | |||||
|
| (hr)(ft2 )(oF) | (m2))(K) | |||
The proposed alternative is 4" (100mm) brick | 1/8" mineral board of k = 0.29, therefore |
| ||||
|
|
|
|
| ||
with a | Rmin.bd. = 1/0.29 x 0.125 = 0.431 | Thermal Conductivity: |
| |||
board with a | Total R = Rbrick + Rmineral board = |
| ||||
|
|
|
|
| ||
Step (a): | 0.8 + 0.431 = 1.231. | k = | (Btu)(inch) | = W | = Btu | |
| ||||||
Step (c): | (hr)(ft3)(oF) |
| (m)(K) | (hr)(ft)(oF) | ||
Use formula above to convert specifi cation |
| |||||
|
|
|
|
| ||
to | Compare proposed system R of 1.231 to | Thermal Resistance: |
| |||
R = 1/k x T = 1/0.84 x .75 = 0.893. | specifiedRof0.893.Sinceproposedsystem |
| ||||
|
|
|
|
| ||
| R is greater than required, the system is | R = (ft2)(hr)(oF) = | (m2)(K) | |||
| acceptable. | |||||
|
|
| Btu |
| W | |
|
|
|
|
| ||