COMBUSTION AIR ASSEMBLY

MODEL AK-4 COMBUSTION AIR ASSEMBLY

1.Remove the cover plate from the 4-inch outlet opening location on the left outside of the fireplace. DO NOT remove the cover if the outside air will not be connected.

2.Place the insulation ring between the AK-4 starting collar and fireplace wall and place the starting collar (4 inch) into the hole on the left side of the fireplace. Fasten it in place with the four sheet metal screws provided.

3.Cut a 6-inch diameter opening for model AK-4 in the outside wall covering where the outside vent is to be located.

4.Select and cut a piece of duct sufficient length to attach to the fireplace and protrude at least three inches beyond the face of the wall to which the AK-4 inlet air vent will be attached. The duct may be cut with a standard pocket knife (use FP-4 U duct for maximum efficiency and safety). Do not use a combustible duct. Always use UL Listed Class 0 or 1 duct material.

5.If the duct is the insulated type, push the insulation back from one end of the duct approximately two inches.

6.Slip the exposed end of the duct over the starting collar on the fireplace.

7.Using the sheet metal screws provided, secure the duct end to the collar attached to the fireplace.

8.Nail or screw the combustion air assembly to the surface of the wall.

NOTE: If the wall covering is brick or stone, use appropriate masonry fasteners. Mount the combustion air assembly with “TOP’” upward to prevent cold air from entering through the wall. If it is necessary to splice the duct, a model 403-duct connector should be used to splice duct sections.

23

53D9028. Rev 1 03/03

Image 24
Contents SB5400SS Model Table of Contents CongratulationsImportant Information Intended Product UsageOperation Guidelines Residential Installation ClearancesMantel Installation Combustible Framing TOP of SpacersTOP of Spacers MAX Combustible Mantel TOP Edge of Fireplace Manufacturer Recommendation TOP Edge Fireplace OpeningSeries Chimney Sections Fireplace Location Installation Preparation Single Story Installation with Attic Space Floor Protection H2068 Hearth Extension Or EquivalentMetal Safety Strip Combustible Floor Fireplace Components LCSLCL LclfFireplace Installation Chimney Installation Installation of FIRESTOP-SPACER AT Attic Level Minimum Required Roof OpeningMinimum Framed Opening SeriesChimney Offset Installation Chimney Offset and CAP Installation CenterlineChimney Chimney CAP Installation Chimney Height and Offset Charts Intermediate Height Sections InchesChimney Sections with Elbow Offsets Total SET Chimney CAP Chase Installation Outside Combustion AIR Precautions & Recommendations Installation Above Basement Or Crawl SpaceOutside Combustion AIR Recommendations Combustion AIR Assembly GAS Appliance Installation Important NoticesApplying Decorative Trim to the Fireplace Trim and Door Installation Mantel Inst AllationFireplace Operation Species Density Heat Value Maintenance and Safety DO’S DONT’S Parts Diagram and List Limited Warranty Limitations and ExclusionsIf YOU have a Problem with Your Fireplace or Component Your DutiesAppliance Installer