Martin Fireplaces SB5400SS manual Outside Combustion AIR Recommendations

Page 23

OUTSIDE COMBUSTION AIR PRECAUTIONS & RECOMMENDATIONS

OUTSIDE COMBUSTION AIR RECOMMENDATIONS (CONTINUED)

1.Extremely long runs and numerous turns in the duct leading from the fireplace to the combustion air assembly should be avoided. These conditions will increase the resistance to the free flow of air through the duct. Refer to Figures 1, 23, and 24 for methods of installing the outside air for combustion assemblies.

2.The combustion air assembly should be located at an exterior location, which is not likely to be accidentally blocked in any manner. The assembly should be located above the snow line to prevent blockage by snow accumulation.

3.The combustion air inlet assembly should never be mounted in a garage or storage area where combustible fumes such as gasoline might be drawn into the fireplace.

4.Combustion air can be drawn form the crawl space under a house when an adequate supply of air is provided by open ventilation.

5.Do not take combustion air from attic space or garage space.

FIGURE 24

NAIL

HOLES

SCREWS

6" DIA. HOLE FOR AK-4

COMBUSTION AIR ASSEMBLY

FOR MODEL NO. AK-4

OUTSIDE AIR CONTROL

LEVER (LIFT TO OPEN,

PULL DOWN TO CLOSE)

22

53D9028. Rev 1 03/03

Image 23
Contents SB5400SS Model Congratulations Table of ContentsIntended Product Usage Important InformationOperation Guidelines Clearances Residential InstallationManufacturer Recommendation TOP Edge Fireplace Opening Mantel Installation Combustible FramingTOP of Spacers TOP of Spacers MAX Combustible Mantel TOP Edge of FireplaceSeries Chimney Sections Fireplace Location Installation Preparation Single Story Installation with Attic Space H2068 Hearth Extension Or Equivalent Floor ProtectionMetal Safety Strip Combustible Floor Lclf Fireplace ComponentsLCS LCLFireplace Installation Chimney Installation Series Installation of FIRESTOP-SPACER AT Attic LevelMinimum Required Roof Opening Minimum Framed OpeningChimney Offset Installation Chimney Chimney Offset and CAP InstallationCenterline Chimney CAP Installation Chimney Sections with Elbow Offsets Total SET Chimney Height and Offset ChartsIntermediate Height Sections Inches Chimney CAP Chase Installation Installation Above Basement Or Crawl Space Outside Combustion AIR Precautions & RecommendationsOutside Combustion AIR Recommendations Combustion AIR Assembly Important Notices GAS Appliance InstallationApplying Decorative Trim to the Fireplace Mantel Inst Allation Trim and Door InstallationFireplace Operation Species Density Heat Value Maintenance and Safety DO’S DONT’S Parts Diagram and List Limitations and Exclusions Limited WarrantyYour Duties If YOU have a Problem with Your Fireplace or ComponentAppliance Installer