Majestic SR36A Planning Information, Mounting the Fireplace, Planning the Chimney Run, 7412948

Page 7
Planning Information

SR/SC Series "A" Woodburning Fireplace

Planning Information

Preplanning an installation is very important to ensure safety and to save time and money. An installer must predetermine where a fireplace will be set and how the chimney system will be run.

Mounting the Fireplace

A fireplace may only be mounted on the following sur- faces:

1.A flat combustible surface.

2.A raised wooden platform.

3.A concrete block or other solid object placed beneath each of the four (4) corners of the fireplace.

The fireplace must be spaced 1/2" (13 mm) from a combustible back wall and 1/2" (13 mm) from a com- bustible side wall or support. (Page 14, Fig. 20)

Planning the Chimney Run

L

 

T

 

 

TOTAL

INSTALLED

 

 

 

 

 

MODEL SK

LENGTH

LENGTH

 

 

 

2 WALL CHIMNEY

(LT)

(L1)

 

 

 

 

 

 

 

 

 

 

SK81

 

 

L1

 

11���"

10���"

 

 

 

 

SK818

17���"

16���"

 

 

 

 

 

 

 

SK83

35���"

34���"

 

 

 

L1

 

SK84

47���"

46���"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WF288

Fig. 7 Installed lengths of chimney sections.

Determine how the chimney will be run, length of run and chimney components required to complete the job. (Fig. 6) Never install a chimney below minimum heights.

In planning a chimney system, it is important to know:

1.The height of a chimney is measured from the hearth to the exit point on the termination.

2.A chimney cannot be offset more than 30° from a vertical plane.

3.A chimney may run straight up or it may be neces- sary to offset it to avoid obstructions.

4.The maximum length of an angled run (total chimney system) is 20' (6m).

5.No more than 2 offsets (4 total 30° elbows in U.S./or 2 total 45° elbows in Canada) per fireplace may be used.

6.A guy wire stabilizer is required for chimneys extend- ing more than 6' (1.8m) above a roof line.

The Ten Foot Rule

Major U.S. building codes specify a minimum chimney height above the roof top. The “Ten Foot Rule” is a fire safety rule and not a draft rule. To ensure proper draft, it is recommended that you always meet or exceed the “Ten Foot Rule,” especially when installing a termination on a high pitch roof. (Fig. 8)

The key points of the "Ten Foot Rule" are:

1.If the horizontal distance from the chimney to the peak of the roof is 10' (3m) or less, the top of the chimney must be at least 2' (610mm) above the peak of the roof, but never less than 3' (914mm) in height above the highest point where it passes through the roof.

2.If a horizontal distance from the chimney to the peak of the roof is more than 10' (3m), a chimney height reference point is established on the surface of the roof a distance of 10' (3m) from the chimney in a horizontal plane. The top of the chimney must be at least 2' (610mm) above the reference point, but never less than 3' (614mm) in height above the high- est point where it passes through the roof.

0 To 10'

 

2' Min. 3'

0 To 10'

Min.

 

 

2' Min. 3'

 

Min.

Reference

Point

AC246

Fig. 8 Ten Foot Rule illustration.

7412948

7

Image 7
Contents Homeowners Installation and Operating Manual Woodburning FireplaceSC36A, SR36A SC42A, SR42A DO NOT DISCARD THIS MANUAL Retain for future useSR/SC Series A Woodburning Fireplace Safety InformationTable of Contents PrecautionsFig. 1 SR36A Series specifications and framing SR36A Series Woodburning FireplaceSR/SC Series A Woodburning Fireplace 7412948Fig. 3 SR42A Series specifications and framing SR42A Series Woodburning FireplaceSR/SC Series A Woodburning Fireplace 7412948for cold climate, not Chase InstallationSR/SC Series A Woodburning Fireplace Insulation methodsSR/SC Series A Woodburning Fireplace Chimney Requirements - Offset Installations30˚ Elbow Offsets Illustration KeyThe Ten Foot Rule Planning InformationMounting the Fireplace Planning the Chimney RunInsulating Fireplace Enclosure for Cold Climates InstallationChase Installation Chimney SupportsFraming Installing Electrical Wire for Circulator ModelsInstall Fan Kit Assembly Chimney SetupCutting the Hole Straight-UpChimney InstallationOffset Installation Ceiling Chimney Hole Possible ObstructionsSR/SC Series A Woodburning Fireplace Positioning, Safety Strips Securing the FireplaceInstalling Outside Air Kit Installing the Chimney SystemCanadian Requirements for Insulation Shield Installing the Firestop SpacerProper Firestop Spacer Installation in the Ceiling HolePenetrating the Roof Continue Installing Pipe to Complete RunInstall Remainder of Chimney Sections Additional CeilingsFinish Wall Installing Top Housing or TerminationInstalling Chimney In a Chase FinishingMantel Clearance - Radiant Model SR/SC Series A Woodburning Fireplace7412948 Mantel Clearance - RadiantMinimum Wall Clearances Hearth InstallationMinimum Hearth Extension Dimensions Side Wall Protection7412948 COMMON MATERIALS AND FACTORSExample for Common Brick SR/SC Series A Woodburning FireplaceSR/SC Series A Woodburning Fireplace Installing Line for Gas LogsSR/SC36A SR36A/42A, SC36A/42A SERIESSR/SC Series A Woodburning Fireplace DescriptionSR/SC Series A Woodburning Fireplace Accessories7412948 SR/SC Series A Woodburning Fireplace Chimney Components7412948 SR/SC Series A Woodburning Fireplace Chimney Components cont Canada7412948 Limitations and Exclusions Except Blowers What is Covered and For How LongWhat is Not Covered Factory-BuildFireplace and Components149 Cleveland Drive Paris, Kentucky MHSC