Majestic SC42A Framing, Installing Electrical Wire for Circulator Models, EB1 Receptacle Hook-Up

Page 9
Framing

Framing

Framing can be constructed before or after the fireplace is set in place, however, most installers build the frame before setting the fireplace.

Frame fireplace with 2 x 4 lumber or heavier materials. Refer to framing dimensions in Figures 1, 2, 3 or 4 for basic fireplace specifications.

NOTE: Framing should be positioned to accommodate wall covering and fireplace facing material.

Installing Electrical Wire

(for Circulator Models)

If a circulating fireplace is to be installed, run the 120 VAC, 60 Hz wiring to the left side of installation. Wiring must be completed before the fireplace is secured and finish material applied.

Remove the cover plate and electrical knockout on the lower left side of the fireplace and set aside. Follow the instructions on Page 10 for proper wiring and installation of the EB1.

If the fan kit is not being installed with the fireplace, it is highly recommended that 120 VAC supply be made available since someone may elect to install a blower at a later date.

Hard Flat

Surface

Installing Electrical WireOption For Circulating Models Only — Insulation

Platform

FP555

Fig. 10 Insulating between platform and fireplace.

SR/SC Series "A" Woodburning Fireplace

Option For Circulating Models Only —

EB1 (Receptacle) Hook-Up

Wiring should be installed by a certified electrician.

Turn off circuit breaker before wiring models.

Once fireplace is secured, complete wiring the fan kit. Remove knockout in the center of the back of the EB1 and install listed cable clamps. Feed electri- cal wire through listed cable clamp leaving approxi- mately six (6) inches of wire exposed through the EB1. Secure listed cable clamp to the wire.

Attach white wire from power source to one (1) wire of receptacle and secure with nut. Attach black wire from power source to the other wire of recep- tacle and secure with nut. Be sure nuts are secured tightly.

Secure EB1 assembly to inside of electrical box coverplate using two screws. Attach cover to face of the EB1 while being careful to position excess wire completely within the EB1, then attach coverplate to fireplace.

Install Fan Kit Assembly

Refer to optional Model FK12 fan kit assembly in- stallation instructions for field installation.

Chimney Setup

Since you have already preplanned the chimney run, you should know exactly how the installation is to be ac- complished — how much pipe is required, the number of elbows, if any, and type of termination to be used.

CAUTION: REPORT TO YOUR DEALERS ANY PARTS DAMAGED IN SHIPMENT, SPECIFICALLY CHECK THE END CONNECTION OF CHIMNEY SEC- TIONS AND ELBOWS.

NOTE: Fireplaces may use MHSC model SK8, or Mod- el S (three wall) chimney systems. The SR/SC Series "A" Fireplace will accept the SK8 chimney system as is; but a TWABR adapter collar is required when using the Model S (triple wall) chimney system. The installation procedure described in this manual applies only to the SK8 system. Either chimney system may be used, but may not be mixed.

7412948

9

Image 9
Contents SC36A, SR36A SC42A, SR42A Woodburning FireplaceDO NOT DISCARD THIS MANUAL Retain for future use Homeowners Installation and Operating ManualTable of Contents Safety InformationPrecautions SR/SC Series A Woodburning FireplaceSR/SC Series A Woodburning Fireplace SR36A Series Woodburning Fireplace7412948 Fig. 1 SR36A Series specifications and framingSR/SC Series A Woodburning Fireplace SR42A Series Woodburning Fireplace7412948 Fig. 3 SR42A Series specifications and framingSR/SC Series A Woodburning Fireplace Chase InstallationInsulation methods for cold climate, not30˚ Elbow Offsets Chimney Requirements - Offset InstallationsIllustration Key SR/SC Series A Woodburning FireplaceMounting the Fireplace Planning InformationPlanning the Chimney Run The Ten Foot RuleChase Installation InstallationChimney Supports Insulating Fireplace Enclosure for Cold ClimatesInstall Fan Kit Assembly Installing Electrical Wire for Circulator ModelsChimney Setup FramingOffset Installation Straight-UpChimney InstallationCeiling Chimney Hole Possible Obstructions Cutting the HoleInstalling Outside Air Kit Positioning, Safety Strips Securing the FireplaceInstalling the Chimney System SR/SC Series A Woodburning FireplaceProper Firestop Spacer Installation Installing the Firestop Spacerin the Ceiling Hole Canadian Requirements for Insulation ShieldInstall Remainder of Chimney Sections Continue Installing Pipe to Complete RunAdditional Ceilings Penetrating the RoofInstalling Chimney In a Chase Installing Top Housing or TerminationFinishing Finish Wall7412948 SR/SC Series A Woodburning FireplaceMantel Clearance - Radiant Mantel Clearance - Radiant ModelMinimum Hearth Extension Dimensions Hearth InstallationSide Wall Protection Minimum Wall ClearancesExample for Common Brick COMMON MATERIALS AND FACTORSSR/SC Series A Woodburning Fireplace 7412948SR/SC Series A Woodburning Fireplace Installing Line for Gas LogsSR/SC Series A Woodburning Fireplace SR36A/42A, SC36A/42A SERIESDescription SR/SC36AAccessories SR/SC Series A Woodburning Fireplace7412948 Chimney Components SR/SC Series A Woodburning Fireplace7412948 Chimney Components cont Canada SR/SC Series A Woodburning Fireplace7412948 What is Not Covered Except Blowers What is Covered and For How LongFactory-BuildFireplace and Components Limitations and Exclusions149 Cleveland Drive Paris, Kentucky MHSC