Regency I2400M Floor Protection, Firebrick Assembly, Draft Control, Screen Door, Door Handle

Page 12

INSTALLATION

FLOOR PROTECTION

 

 

is burning. Though there are four air tubes

 

 

 

 

ensure the tube will not move when the unit

Please check to ensure that your floor protection

 

 

in the medium units.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and hearth will meet the standards for clearance

2) Slide the left baffle over the air tubes from

to combustibles. Your hearth extension must be

 

 

the front and then push it to the back.

made from a non-combustible material.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIREBRICK ASSEMBLY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Firebrick is included to extend the life of your

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

insert and radiate heat more evenly. Check to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

see that all firebricks are in their correct posi-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tions and have not become misaligned during

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

shipping.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Side View

 

 

 

 

 

 

 

 

 

 

 

DRAFT CONTROL

Before establishing your first fire, it is important that your fully understand the operation of you draft control. The draft rod is on the left side of the Inserts and it controls the intensity of the fire by increasing or decreasing the amount of air allowed into the firebox. To increase your draft - pull open, and to decrease - push closed.

Pull Open

Push Closed

3)Tilt the left baffle up on top of the side chan- nel and it will leave enough room to position the right baffle in the same manner as Step 1) above. Then reposition the left baffle flat on the air tubes.

Front View

As well as a primary and glass wash air system, the unit has a full secondary draft system that allows air to the induction ports at the top of the firebox, just below the flue baffle.

WARNING: To build a fire in ignorance or to disregard the information contained in this section can cause serious permanent dam- age to the unit and void your warranty.

SCREEN DOOR

Hook screen to the inside on the right side of the firebox door opening. Lock in place by turning handle.

FLUE BAFFLE &

SECONDARY AIR TUBE

INSTALLATION

The flue baffle system located in the upper area of the firebox is removable to make cleaning your chimney system easier. The baffles must be installed prior to your first fire. Smoke spill- age and draft problems may occur if the baffles are improperly positioned. Check the position of the baffles on a regular basis as they can be dislodged if too much fuel is forced into the firebox.

The unit arrives with the 2 baffle plates on the floor of the firebox.

1)If all 4 air tubes are installed continue on to Step 2), if not, follow the instructions below. Install the air tube into the holes in the side channels. The notch goes on the right hand side with the air holes facing toward the door. Slide the tube into the left hand side, as far as possible and then bring it back into the hole on the right hand side. Use a pair of vise grips or pliers and tap it into place with a hammer. A tighter fit will

4)Important: push both baffles so they are tight against the side walls.

Front View

DOOR HANDLE

Attach spring handle by rotating counter clock- wise onto rod. Ensure that the rod fits into the entire length of the spring handle.

Hooks

Handle Lock

Back Side of Screen Shown

NOTE: The handle must be positioned at 10 o'clock when closed to avoid the handle from getting hot and to ensure the screen stays in place.

Handle at 10 o'clock position.

12

Regency I2400M

Image 12
Contents Wood Regency Fireplace Product Table of Contents Safety Label 246Unit Dimensions Installation Before Installing Your InsertChimney Specifications Wood Insert SpecificationsInstalling Your Insert Optional Flue Connector KITMasonry and Factory Built Fireplace Clearances Step bFlue Connector Bracket STEP-BY-STEP Installation Into a Factory Built FireplaceSTEP-BY-STEP Installation Faceplate and Trim STEP-BY-STEP Installation FAN/BLOWER Firebrick Assembly Flue Baffle Secondary AIR Tube InstallationFloor Protection Draft ControlSome Safety Guidelines Operating InstructionsFirst Fire ASH Disposal FAN OperationWood Storage Maintenance Parts List Main Assembly & Options I2400MFaceplates I2400M Brick Panels I2400M Warranty Warranty LifetimeInstaller Please complete the following information

I2400M specifications

The Regency I2400M is a notable addition to the world of portable two-way radios, catering to both professional users and hobbyists. This device is designed for those who require reliable communication in various environments, from outdoor adventures to demanding work sites. With its robust build and advanced features, the I2400M has gained a reputation for efficiency and performance.

One of the main features of the I2400M is its dual-band capability, allowing users to operate on both VHF and UHF frequencies. This provides increased flexibility in communication since users can choose the optimal band for their specific environment. The radio's ability to support a wide range of frequencies ensures clear and uninterrupted communication, even in densely populated areas where interference is common.

The I2400M is equipped with a powerful 5W output, ensuring that users can maintain strong signal strength over long distances. This feature is particularly beneficial for those working in expansive outdoor settings, such as construction sites or large events, where clear communication is vital for safety and coordination.

In terms of technology, the Regency I2400M boasts digital signal processing (DSP) which enhances audio quality and clarity. This technology reduces background noise, allowing users to communicate effectively even in noisy conditions. The radio also features programmable channels, enabling users to customize their communication preferences easily.

Battery longevity is another hallmark of the I2400M, with an efficient lithium-ion battery providing extended usage times. Users can rely on this model for long shifts or extended trips without the constant worry of recharging. The radio's design includes a battery-saving mode, further extending operational time by reducing power consumption during inactive periods.

Additionally, the I2400M is built to withstand harsh conditions, featuring an IP67 rating for water and dust resistance. This rugged construction makes it ideal for outdoor use, ensuring functionality in diverse environments, from rainy weather to dusty locations.

Other noteworthy characteristics include a backlit LCD display for easy visibility in low-light conditions, a built-in flashlight for emergencies, and a user-friendly interface that allows for quick access to essential functions. The I2400M's compact size and lightweight design make it highly portable, perfect for users on the go.

Overall, the Regency I2400M stands out as a powerful, versatile, and reliable two-way radio, equipped with features and technologies that meet the demands of modern communication needs. Whether for professional use or recreational adventures, it provides a dependable solution for staying connected.