Regency I2400M Installation, Before Installing Your Insert, Chimney Specifications

Page 6

INSTALLATION

Regency Inserts are constructed with the high- est quality materials and assembled under strict quality control procedures that insure years of trouble free and reliable performance.

It is important that you read this manual thor- oughly and fully understand the safe instal- lation and operating procedures. The more you understand the way your Regency Insert operates, the more enjoyment you will experi- ence from knowing that your unit is operating at peak performance.

BEFORE INSTALLING

YOUR INSERT

1)Please read this entire manual before you install and use your new wood insert. Failure to follow instructions may result in property damage, bodily injury or even death. Install and use only in accordance with manufactur- er’s installation and operating instructions.

2)Check your local building codes - Building Inspection Department. You may require a permit before installing your insert. Be aware that local codes and regulations may override some items in the manual.

WARNING: Careless installation is the major cause of safety hazard. Check all local building and safety codes before installation of unit.

3)Notify your home insurance company that you plan to install a fireplace insert or hearth heater.

4)Your fireplace insert is heavy and requires two or more people to move it safely. The insert can be badly damaged by mishan- dling.

5)If your existing fireplace damper control will become inaccessible once you have installed your Regency Insert, you should either remove or secure it in the open posi- tion.

6)Inspect your fireplace and chimney prior to installing your insert to determine that it is free from cracks, loose mortar or other signs of damage. If repairs are required, they should be completed before installing your insert. Do not remove bricks or mortar from your masonry fireplace.

7)Do not connect the insert to a chimney system servicing another appliance or an air distribution duct.

Emissions from burning wood or gas could contain chemicals known to the State of Cali- fornia to cause cancer, birth defects or other reproductive harm.

CHIMNEY

SPECIFICATIONS

Before installing, check and clean your chimney system thoroughly. If in doubt about its condi- tion, seek professional advice. Your Regency Insert is designed for installation into a masonry fireplace that is constructed in accordance with the requirements of "The Standard for Chimneys, Fireplaces, Vents, and Solid Fuel Burning Ap- pliance", N.F.P.A. 211, the National Building Code of Canada, or the applicable local code requirements.

The appliance, when installed, must be electri- cally grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code,ANSI/NFPA70, or the Canadian Electrical code, CSA C22.1.

Regency Inserts are designed with a 6" (152mm) flue.

Requirements for Installing

Solid-fuel Inserts in Factory-built

Fireplaces.

1)The insert must be tested and meet the requirements of UL 1482 (U.S.) and or ULC S628 (Canada) when tested in a masonry fireplace built per ULC S628.

2)The factory-built fireplace must be listed per UL 127 or ULC S610.

3)Clearances obtained from the masonry fire- place tests are also relevant for installation in factory-built fireplaces.

4)Installation must include a full height listed chimney liner type HT requirements (2100 degree F.) per UL 1777 (U.S.) or ULC S635 (Canada). The liner must be securely attached to the insert flue collar and the chimney top.

5)Means must be provided to prevent room air passage to the chimney cavity of the fireplace. This may be accomplished by sealing the damper area around the chimney liner, or sealing the fireplace front.

6)Alteration of the fireplace in any manner is not permitted with the following exceptions;

a.external trim pieces which do not affect the operation of the fireplace may be removed providing they can be stored on or within the fireplace for re-assembly if the insert is removed.

b.the chimney damper may be removed to install the chimney liner.

7)Circulating air chambers (i.e. in a steel fireplace liner or metal heat circulator) shall not be blocked.

8)Means must be provided for removal of the insert to clean the chimney flue.

9)Inserts that project in front of the fireplace must be supplied with appropriate supporting means.

10)Installer must mechanically attach the sup- plied label to the inside of the firebox of the fireplace into which the insert is installed.

"WARNING: This fireplace has been converted for use with a wood insert only and cannot be used for burning wood or solid fuels unless all original parts have been replaced, and the fireplace re-approved by the authority having jurisdiction."

In order for a solid-fuel insert to be certified for use in factory-built fireplaces, the above information must be clearly stated in the instal- lation manual and appropriate markings. Final approval is contingent on the authority having jurisdiction.

WOOD INSERT

SPECIFICATIONS

Your fireplace opening requires the following minimum sizes:

Height: 21.5"

Width: 25"

Depth: 17"

Two faceplates are available to seal the fireplace opening:

Standard

Oversize

40" W x 30" H

48" W x 33" H

6

Regency I2400M

Image 6
Contents Wood Regency Fireplace Product Table of Contents Safety Label 246Unit Dimensions Chimney Specifications InstallationBefore Installing Your Insert Wood Insert SpecificationsInstalling Your Insert Optional Flue Connector KITMasonry and Factory Built Fireplace Clearances Step bFlue Connector Bracket STEP-BY-STEP Installation Into a Factory Built FireplaceSTEP-BY-STEP Installation Faceplate and Trim STEP-BY-STEP Installation FAN/BLOWER Floor Protection Firebrick AssemblyFlue Baffle Secondary AIR Tube Installation Draft ControlSome Safety Guidelines Operating InstructionsFirst Fire ASH Disposal FAN OperationWood Storage Maintenance Parts List Main Assembly & Options I2400MFaceplates I2400M Brick Panels I2400M Warranty Warranty LifetimeInstaller Please complete the following information

I2400M specifications

The Regency I2400M is a notable addition to the world of portable two-way radios, catering to both professional users and hobbyists. This device is designed for those who require reliable communication in various environments, from outdoor adventures to demanding work sites. With its robust build and advanced features, the I2400M has gained a reputation for efficiency and performance.

One of the main features of the I2400M is its dual-band capability, allowing users to operate on both VHF and UHF frequencies. This provides increased flexibility in communication since users can choose the optimal band for their specific environment. The radio's ability to support a wide range of frequencies ensures clear and uninterrupted communication, even in densely populated areas where interference is common.

The I2400M is equipped with a powerful 5W output, ensuring that users can maintain strong signal strength over long distances. This feature is particularly beneficial for those working in expansive outdoor settings, such as construction sites or large events, where clear communication is vital for safety and coordination.

In terms of technology, the Regency I2400M boasts digital signal processing (DSP) which enhances audio quality and clarity. This technology reduces background noise, allowing users to communicate effectively even in noisy conditions. The radio also features programmable channels, enabling users to customize their communication preferences easily.

Battery longevity is another hallmark of the I2400M, with an efficient lithium-ion battery providing extended usage times. Users can rely on this model for long shifts or extended trips without the constant worry of recharging. The radio's design includes a battery-saving mode, further extending operational time by reducing power consumption during inactive periods.

Additionally, the I2400M is built to withstand harsh conditions, featuring an IP67 rating for water and dust resistance. This rugged construction makes it ideal for outdoor use, ensuring functionality in diverse environments, from rainy weather to dusty locations.

Other noteworthy characteristics include a backlit LCD display for easy visibility in low-light conditions, a built-in flashlight for emergencies, and a user-friendly interface that allows for quick access to essential functions. The I2400M's compact size and lightweight design make it highly portable, perfect for users on the go.

Overall, the Regency I2400M stands out as a powerful, versatile, and reliable two-way radio, equipped with features and technologies that meet the demands of modern communication needs. Whether for professional use or recreational adventures, it provides a dependable solution for staying connected.