Wayne ESP45 specifications Description, Unpacking, Safety Guidelines, General Safety Information

Page 1

Operating Instructions and Parts Manual

Limited Warranty

For two years from the date of purchase, Wayne Water Systems (“Wayne”) will repair or replace, at its option, for the original purchaser any part or parts of its Sump Pumps or Water Pumps (“Product”) found upon examination by Wayne to be defective in materials or workmanship. Please call Wayne (800-237-0987) for instructions or see your dealer. Be prepared to provide the model and serial number when exercising this warranty. All transportation charges on Products or parts submitted for repair or replacement must be paid by purchaser.

This Limited Warranty does not cover Products which have been damaged as a result of accident, abuse, misuse, neglect, improper installation, improper maintenance, or failure to operate in accordance with Wayne’s written instructions.

Operating Instruction and Parts Manual

ESP45

 

 

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.

24-Volt Backup

Sump

Pump

THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO TWO YEARS FROM THE DATE OF PURCHASE. THIS IS THE EXCLUSIVE REMEDY AND ANY LIABILITY FOR ANY AND ALL INDIRECT OR CONSEQUENTIAL DAMAGES OR EXPENS- ES WHATSOEVER IS EXCLUDED.

Some states do not allow limitations on how long an implied warranty lasts, or do not allow the exclusions or limitations of incidental or consequential damages, so the above limitations might not apply to you. This limited warranty gives you specific legal rights, and you may also have other legal rights which vary from state to state.

In no event, whether as a result of breach of contract warranty, tort (including negligence) or otherwise, shall Wayne or its suppliers be liable for any special, consequential, incidental or penal damages including, but not limited to loss of profit or revenues, loss of use of the products or any associated equipment, damage to associated equipment, cost of capital, cost of substitute products, facilities, services or replacement power, downtime costs, or claims of buyer’s customers for such damages.

You MUST retain your purchase receipt along with this form. In the event you need to exercise a warranty claim, you MUST send a copy of the purchase receipt along with the material or correspondence. Please call Wayne (800-237-0987) for return authorization and instructions.

DO NOT MAIL THIS FORM TO WAYNE. Use this form only to maintain your records.

MODEL NO. _____________________ SERIAL NO. ________________________ INSTALLATION DATE _____________________

ATTACH YOUR RECEIPT HERE

Description

The ESP45 is a battery operated back-up sump pump. It does not replace a regular pump. It is designed to provide protection in the event household electrical power fails or main pump fails.

Unpacking

Inspect this unit before it is used. Occasionally, products are damaged during shipment. If the pump or components are damaged, return the unit to the place of purchase for replacement. Failure to do so could result in serious injury or death.

Safety Guidelines

This manual contains information that is very important to know and understand. This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help recognize this information, observe the following symbols.

Danger indicates an imminently

General Safety

Information

CALIFORNIA PROPOSITION 65

This product or its power cord may

contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling.

GENERAL SAFETY

Do not use to pump flammable or explosive fluids such as gasoline, fuel oil, kerosene, etc. Do not use in a flammable and/or explosive atmosphere. Pump should only be used to pump clear water. Fatal injury and/or property damage could result.

If the basement has water or moisture on the floor, do not walk on wet area until all

power is turned off. If the shutoff box is in the basement, call an electrician. Remove pump and either repair or replace. Failure to follow this warning could result in fatal electrical shock.

All wiring must be performed by a

qualified electrician.

Do not expose battery to sparks or flames as an explosion or fire could result.

Battery acid is corrosive. Avoid spilling on skin or clothing. Eye protection must

be worn when handling the battery. A check valve must be used on the

primary sump pump discharge.

A ground fault circuit interrupter is required.

This pump must only be used to pump clear water. This pump is not designed to handle effluent, salt water, brine, laundry discharge or any other application which may contain caustic chemicals and/or foreign materials. Pump damage may occur if used in these applications and will void warranty.

hazardous situation which, if not avoided, will result in death or serious injury.

Warning indicates a potentially

hazardous situation which, if not avoided, could result in death or serious injury.

Caution indicates a potentially

hazardous situation which, if not avoided, may result in minor or moderate injury.

Notice indicates important

information, that if not followed, may cause damage to equipment.

Pump Specifications

Power supply requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120V, 60 Hz Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Perminent Magnet DC Motor Normal water removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2880 GPH @ 5 Feet @ 26V DC Liquid temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40°F to 120°F Circuit requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 amps AC (min) Pump Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 in. high x 8 3/4 in. base Pump run time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Seconds

Pump Construction

Motor housing, volute, seal plate

. . . . Cast Iron

Impeller

Thermoplastic

Shaft

Stainless Steel

Discharge

. . 11/2 in. NPT

Float switch

. . . Reed Style

www.waynepumps.com

REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.

© 2008 Wayne Water Systems

For parts, product & service information

353601-001 7/08

visit www.waynepumps.com

8

Image 1
Contents General Safety Information Safety GuidelinesDescription UnpackingPS/BC Features Battery InformationPump Installation MaintenancePump Installation Method 1 PreferredChart 2 PS/BC Status Lights On When Action Required PS/BC InstallationOperation Batteries
Related manuals
Manual 24 pages 13.92 Kb

ESP45 specifications

The Wayne ESP45 is a standout model in the world of submersible sump pumps, renowned for its efficiency, durability, and innovative technology. This pump is designed for residential and commercial applications, providing reliable protection against water damage caused by flooding or excess groundwater.

One of the key features of the Wayne ESP45 is its powerful motor. Equipped with a 1/2 HP motor, it is capable of displacing up to 4,600 gallons of water per hour. This makes it suitable for handling heavy inflows during significant rain events or for managing water pooling in basements. The motor is also thermally protected, ensuring it doesn’t overheat during prolonged use, thereby enhancing its longevity.

The ESP45 employs a superior engineering design that includes a durable thermoplastic construction. This material protects the pump from corrosion and wear, ideally suited for dealing with harsh conditions typically found in sump applications. The pump is designed for consistent performance and operates quietly, minimizing disturbances in your living space.

One of the standout technologies in the Wayne ESP45 is its vertical float switch, which provides automatic operation. This feature allows the pump to turn on and off based on water levels, ensuring that your sump area is always protected without the need for manual intervention. The float switch is built to withstand wear and tear, allowing for reliable operation over time.

Another characteristic that sets the Wayne ESP45 apart is its ease of installation. The pump comes with a simple setup process, featuring a standard 1-1/2 inch NPT discharge that easily connects to existing plumbing systems. This allows homeowners and contractors to install the pump quickly, making it an ideal choice for those looking to enhance their water management solutions efficiently.

Moreover, the Wayne ESP45 is compatible with various backup systems, offering peace of mind by ensuring that it remains operational during power outages. This versatility increases its reliability, making it a go-to option for anyone looking to safeguard their property from water damage.

In summary, the Wayne ESP45 combines powerful performance, durable construction, and innovative technology, making it one of the most reliable submersible sump pumps available. With its efficient motor, advanced automatic operation, and simple installation process, it serves as an essential tool for protecting homes from flooding and water damage.