Wayne ESP45 specifications Safety Guidelines, Description, Unpacking, Specifications

Page 1

PLEASE READ AND SAVE THESE INSTRUCTIONS. READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

OPERATING

MODEL

INSTRUCTIONS

ESP45

AND PARTS

 

MANUAL

 

24-Volt Backup Sump Pump

SAFETY GUIDELINES

This manual contains information that is very important to know and understand. This information is provided for SAFETY and to

PREVENT EQUIPMENT PROBLEMS. To help recognize this information, observe the following symbols.

Danger indicates an imminently hazardous situation which, if not avoided, WILL result in death or serious injury.

Warning indicates a potentially hazardous situation which, if not avoided, COULD result in death or serious injury.

Caution indicates a potentially hazardous situation which, if not avoided, MAY result in minor or moderate injury.

Notice indicates important information, that if not followed, may cause damage to equipment.

DESCRIPTION

The ESP45 is a battery operated back- up sump pump. It does not replace a regular pump. It is designed to provide protection in the event household electrical power fails or main pump fails.

UNPACKING

Inspect this unit before it is used. Occasionally, products are damaged during shipment. If the pump or components are damaged, return the unit to the place of purchase for replacement. Failure to do so could result in serious injury or death.

GENERAL SAFETY INFORMATION

CALIFORNIA PROPOSITION 65

This product or its power cord contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling.

GENERAL SAFETY

Do not use to pump

flammable or explosive fluids such as gasoline, fuel oil,

kerosene, etc. Do not use in a flammable and/or explosive atmosphere. Personal injury and/or property damage could result.

Disconnect power before servicing. If the power disconnect is out of sight, lock

in the open position and tag it to prevent unexpected application of power. Failure to do so could result in fatal electrical shock!

If the basement has water or moisture on the floor, do not walk on wet area until all power is turned off. If the shutoff box is in the basement , call an electrician. Remove pump and either repair or replace. Failure to follow this warning could result in fatal electrical shock.

All wiring must be performed by a qualified electrician.

Do not expose battery to sparks or flames as an explosion or fire could result.

Battery acid is corrosive. Avoid spilling on skin or clothing. Eye protection must

be worn when handling the battery.

A check valve must be used on the primary sump pump discharge.

SPECIFICATIONS

Power supply requirements

120V, 60 Hz

Motor

Permanent Magnet DC Motor

Normal water removal

2880 GPH @5 ft. @ 26V DC

Liquid temperature range

40º F to 120º F

Circuit requirements

5 amps AC (min)

Pump Dimensions

11 inch high x 8-3/4 inch base

Pump Run Time

15 Seconds

CONSTRUCTION

Motor housing

Cast Iron

Impeller

Thermoplastic

Shaft seal

Stainless Steel

Discharge

1-1/2 inch NPT

Float Switch

Reed Style

REMINDER: Keep your dated proof of purchase for warranty purposes!

Attach it to this manual or file it for safekeeping.

© 2010 WAYNE Pumps

For parts, product & service information

353502-001 3/10

 

visit www.waynepumps.com

 

Image 1
Contents Specifications Safety GuidelinesDescription UnpackingBattery Information General SafetyPS/BC Features InformationPump Installation Pump InstallationMethod 1 Preferred Methods 1 Control BOX InstallationChart 2 PS/BC Status Lights On When Action Required MaintenanceOperation BatteriesSymptom Troubleshooting ChartPump wont run Possible CausesRef No Description Qty For Replacement Parts or Technical ASSISTANCE, CallAttach Your Receipt Here Limited WarrantyDéballage Directives DE SécuritéSpécifications ConceptionCB/AC Fonctions Information SUR LA BatterieTableau 1- Capacité DE Pompage DE Courant EN Attente Circuits DE CourantMontage DE Pompe PS/BC Features suiteMontage DE Pompe suite PS/BC InstallationMéthode Méthodes 1 ETInstallation DE LA Boîte DE Contrôle Installation DU CB/ACFonctionnement EntretienGuide DE Dépannage Entretien suiteDébrancher le CB/AC Symptôme Causes Possibles Mesures Correctives15 Fr Numéro de No. de Réf Description Pièce Qté16 Fr Fixer Votre Facture ICIDescripción Medidas DE SeguridadDesempacar Informaciones Generales DE SeguridadCaracterísticas DEL PS/BC Información Sobre LA BateríaBomba Instalación DE BombaInstalación DE LA Bomba Método 1 SE PrefiereMétodo Installación DE PS/BCMétodos 1 Y 20 SpFuncionamiento MantenimientoInstalación DE LA Caja DE Control BateríasMantenimiento ProblemaGuía DE Diagnóstico DE Averías Posibles Causas23 Sp Número de De Ref Descripción Pieza Ctd24 Sp Anexe SU Recibo Aqui
Related manuals
Manual 4 pages 42.65 Kb

ESP45 specifications

The Wayne ESP45 is a standout model in the world of submersible sump pumps, renowned for its efficiency, durability, and innovative technology. This pump is designed for residential and commercial applications, providing reliable protection against water damage caused by flooding or excess groundwater.

One of the key features of the Wayne ESP45 is its powerful motor. Equipped with a 1/2 HP motor, it is capable of displacing up to 4,600 gallons of water per hour. This makes it suitable for handling heavy inflows during significant rain events or for managing water pooling in basements. The motor is also thermally protected, ensuring it doesn’t overheat during prolonged use, thereby enhancing its longevity.

The ESP45 employs a superior engineering design that includes a durable thermoplastic construction. This material protects the pump from corrosion and wear, ideally suited for dealing with harsh conditions typically found in sump applications. The pump is designed for consistent performance and operates quietly, minimizing disturbances in your living space.

One of the standout technologies in the Wayne ESP45 is its vertical float switch, which provides automatic operation. This feature allows the pump to turn on and off based on water levels, ensuring that your sump area is always protected without the need for manual intervention. The float switch is built to withstand wear and tear, allowing for reliable operation over time.

Another characteristic that sets the Wayne ESP45 apart is its ease of installation. The pump comes with a simple setup process, featuring a standard 1-1/2 inch NPT discharge that easily connects to existing plumbing systems. This allows homeowners and contractors to install the pump quickly, making it an ideal choice for those looking to enhance their water management solutions efficiently.

Moreover, the Wayne ESP45 is compatible with various backup systems, offering peace of mind by ensuring that it remains operational during power outages. This versatility increases its reliability, making it a go-to option for anyone looking to safeguard their property from water damage.

In summary, the Wayne ESP45 combines powerful performance, durable construction, and innovative technology, making it one of the most reliable submersible sump pumps available. With its efficient motor, advanced automatic operation, and simple installation process, it serves as an essential tool for protecting homes from flooding and water damage.