Operating Instructions and Parts Manual

 

 

 

 

PUMP INSTALLATION

 

 

 

 

(CONTINUED)

 

 

 

 

 

Floor Joist

Ridgid

Slope Pipe

Be careful not to strip or cross thread

 

PVC Pipe

Down

 

 

 

 

plastic fittings or check valves. Flex hose is

 

 

 

 

not recommended. Rigid PVC or metal pipe

 

 

 

 

is required for a permanent installation.

 

 

 

 

6. Place the pump with the 4’ section of

 

 

 

Check Valve

PVC pipe on the sump floor or on an

PS/BC

 

 

(See Step 6)

elevated surface if required.

 

 

 

 

 

 

 

7. Attach a rubber check valve (sold

 

 

 

 

separately) to the top of the discharge

Batteries

 

 

1 1/4 inch or

pipe. This will allow the pump or check

 

 

valve to be removed easily for servicing.

 

 

 

1 1/2 inch

8. Duplicate the discharge piping

 

 

 

PVC Pipe

 

 

 

 

arrangement for the primary AC

 

 

 

 

pump if the existing discharge line

 

 

 

 

has to be adjusted to accommodate

 

 

 

 

a second pump.

 

 

 

 

9. Glue a 45º elbow to the short pipe on

 

 

 

 

the ESP45 pump. Glue a “Y” adapter to

 

ESP45

 

 

the short pipe on the existing pump, as

Battery

 

 

shown in illustration for Method 2.

Box

Pump

 

Existing

10. Glue a short piece of PVC pipe between

 

 

 

Pump

 

 

 

 

the 45º elbow and the “Y”.

Figure 3 – Method 2

 

 

 

NOTE: Check valves can be placed

 

 

 

 

 

 

 

directly in the pump discharge if desired.

 

 

Wear safety goggles when connecting

However, for ease of disassembly, it is

 

 

 

 

batteries. Battery connections should be

recommended that check valves be placed

 

 

Risk of electrical shock! Use a GFCI

made in a well-ventilated area.

above the sump as shown in Figure 3.

(Ground Fault Circuit Interrupter)

1. Place battery box within six feet of the

The remainder of the discharge pipe

receptacle to reduce the risk of fatal

sump and a 115 VAC separately fused

electrical shock. Grounded receptacle

installation will vary depending on

outlet. The outlet must be protected

must be rated for at least 5 amps.

individual circumstances. Using sound

by a ground fault circuit interrupter

 

 

plumbing practices, route the discharge pipe

 

 

(GFCI). The area must also be clean,

to an exterior wall by the shortest distance.

Always disconnect AC power and

dry and well-ventilated.

 

2. Wave cardboard over batteries to blow

METHODS 1 AND 2

remove pump fuse before connecting or

away any gas that may be present.

Install float switch at least 10”-12” above

disconnecting battery.

 

1. Select a suitable position on the floor

3. Connect jumper wire between

bottom of sump pit so that backup unit

turns on only when the water level is higher

near the sump pit to place the battery

batteries as shown on Figure 1.

than the normal “on” level for main pump.

case. Be certain that the PS/BC power

4. Connect power wires from PS/BC to

Use the hose clamps provided to secure the

cord will reach AC power, and that

battery terminals as shown in Figure 1.

switch to the discharge pipe. Make sure

the sump pump power cord will reach

Connect the red wire to the unconnected

power wires and hose clamp ends do not

the PS/BC. Make sure the battery case

positive terminal of battery A and

interfere with float switch, pump inlet, or

vent holes are unobstructed.

then connect the black wire to the

main pump operation. Backup pump must

ELEVATE PS/BC BY MOUNTING ON

unconnected negative terminal of battery

B. The yellow light should now be on.

not be allowed to run dry.

WALL OR SETTING ON A SHELF. SLOTS

5. Plug the pump and then the float into

 

IN THE BACK SIDE OF PS/BC ARE

 

the PS/BC. The connections are marked.

 

AVAILABLE FOR WALL MOUNTING.

 

6. Test pump operation by filling the

Use Power Supply/ Battery Charger (PS/BC)

CONTROL BOX INSTALLATION

sump with water while the main

indoors, in a well-ventilated area. Do not

 

 

pump is unplugged. If the pump

expose PS/BC to rain or snow. Do not use

 

 

 

 

operates properly, plug the PS/BC into

an extension cord. Do not disassemble

 

 

PS/BC. Be sure PS/BC ventilation holes

If cables are reversed, damage to the PS/

the GFCI protected outlet to begin

are unobstructed. If PS/BC is dropped

BC or battery could result, and warranty

charging the battery.

or damaged, do not operate; return to

will be void.

 

NOTE: Protect electrical cord from sharp

Dangerous hydrogen gas can be released

manufacturer for service.

objects, hot surfaces, oil and chemicals.

 

from batteries while charging. Sparks

Avoid kinking the cord and replace

 

can ignite the gas in an enclosed space.

damaged components immediately.

www.waynepumps.com

 

 

 

 

4

Image 4
Contents Safety Guidelines SpecificationsDescription UnpackingGeneral Safety Battery InformationPS/BC Features InformationPump Installation Pump InstallationMethod 1 Preferred Control BOX Installation Methods 1Maintenance Chart 2 PS/BC Status Lights On When Action RequiredOperation BatteriesTroubleshooting Chart SymptomPump wont run Possible CausesFor Replacement Parts or Technical ASSISTANCE, Call Ref No Description QtyLimited Warranty Attach Your Receipt HereDirectives DE Sécurité DéballageSpécifications ConceptionInformation SUR LA Batterie CB/AC FonctionsTableau 1- Capacité DE Pompage DE Courant EN Attente Circuits DE CourantPS/BC Features suite Montage DE PompePS/BC Installation Montage DE Pompe suiteMéthode Méthodes 1 ETInstallation DU CB/AC Installation DE LA Boîte DE ContrôleFonctionnement EntretienEntretien suite Guide DE DépannageDébrancher le CB/AC Symptôme Causes Possibles Mesures CorrectivesNuméro de No. de Réf Description Pièce Qté 15 FrFixer Votre Facture ICI 16 FrMedidas DE Seguridad DescripciónDesempacar Informaciones Generales DE SeguridadInformación Sobre LA Batería Características DEL PS/BCInstalación DE Bomba BombaInstalación DE LA Bomba Método 1 SE PrefiereInstallación DE PS/BC MétodoMétodos 1 Y 20 SpMantenimiento FuncionamientoInstalación DE LA Caja DE Control BateríasProblema MantenimientoGuía DE Diagnóstico DE Averías Posibles CausasNúmero de De Ref Descripción Pieza Ctd 23 SpAnexe SU Recibo Aqui 24 Sp
Related manuals
Manual 4 pages 42.65 Kb

ESP45 specifications

The Wayne ESP45 is a standout model in the world of submersible sump pumps, renowned for its efficiency, durability, and innovative technology. This pump is designed for residential and commercial applications, providing reliable protection against water damage caused by flooding or excess groundwater.

One of the key features of the Wayne ESP45 is its powerful motor. Equipped with a 1/2 HP motor, it is capable of displacing up to 4,600 gallons of water per hour. This makes it suitable for handling heavy inflows during significant rain events or for managing water pooling in basements. The motor is also thermally protected, ensuring it doesn’t overheat during prolonged use, thereby enhancing its longevity.

The ESP45 employs a superior engineering design that includes a durable thermoplastic construction. This material protects the pump from corrosion and wear, ideally suited for dealing with harsh conditions typically found in sump applications. The pump is designed for consistent performance and operates quietly, minimizing disturbances in your living space.

One of the standout technologies in the Wayne ESP45 is its vertical float switch, which provides automatic operation. This feature allows the pump to turn on and off based on water levels, ensuring that your sump area is always protected without the need for manual intervention. The float switch is built to withstand wear and tear, allowing for reliable operation over time.

Another characteristic that sets the Wayne ESP45 apart is its ease of installation. The pump comes with a simple setup process, featuring a standard 1-1/2 inch NPT discharge that easily connects to existing plumbing systems. This allows homeowners and contractors to install the pump quickly, making it an ideal choice for those looking to enhance their water management solutions efficiently.

Moreover, the Wayne ESP45 is compatible with various backup systems, offering peace of mind by ensuring that it remains operational during power outages. This versatility increases its reliability, making it a go-to option for anyone looking to safeguard their property from water damage.

In summary, the Wayne ESP45 combines powerful performance, durable construction, and innovative technology, making it one of the most reliable submersible sump pumps available. With its efficient motor, advanced automatic operation, and simple installation process, it serves as an essential tool for protecting homes from flooding and water damage.