Nimbus Water Systems WM5-50 manual Maintenance, Cartridge Replacement, Post Filter Replacement

Page 9

Maintenance

Cartridge Replacement

1.Close the feed water shut-off valve.

2.Close the tank shut-off valve.

3.Open the dispensing faucet to relieve system pressure. Close dispensing faucet when flow has stopped.

4.Remove the cover from the front of the system. Remove the retaining clip. Pull the cartridge off the system evenly at top and bottom. Dispose of used cartridge.

6.Install the new cartridge, rocking gently from side to side as necessary until the cartridge tubes are properly engaged in the unit connectors. Install the retaining clip, ensuring the slide locks snap into place in the slots. If the clip does not snap easily into place through the slots it means the cartridge is not fully inserted into the connectors. Press the top or bottom of the cartridge to engage the connector so that it snaps fully into place. Failure to properly install the retaining clip will result in accidental leaks and flooding.

7.Turn on feed water shut-off valve and open dispensing faucet.

8.Close dispensing faucet after water starts running.

9.Observe system for any leaks, especially at newly replaced­ cartridge.

10.Open the tank shut-off valve.

11.The system should be flushed at least once as described above under Section 8.

Post Filter Replacement

1.Close the feed water shut-off valve.

2.Close the tank shut-off valve.

3.Open the dispensing faucet.

4.Close the dispensing faucet when the water stops flowing.

5.Locate the inline filter on the faucet line.

6.Remove the red locks from the collets.

7.Remove the tubing by depressing the collet in a downward direction and pulling the blue tubing from the filter.

8.Remove the other side of the feed tubing as described above.

9.Reverse the above steps to install the new inline filter, making sure that the tubing is pressed in as far as possible.

10.Turn on the feed water valve. Observe system for any leaks, especially at newly replaced­ cartridge.

11.Open the tank shut-off valve.

12.The system should be flushed at least once as described in System Activation and Flushing.

41840-A McAlby Court, Murrieta, CA 92562

9

(800) 451-9343, email: sales@nimbuswater.com

 

Image 9 Contents
WM5-50 Introduction to the WaterMaker Five Warranty Performance Specifications System Specifications Push Handle Airgap Faucet Feed and Drain Connection Feed ConnectionDrain Connection Initial Flushing Procedure System Activation and FlushingSystem Activation and Inspection Installation Checklist Maintenance Cartridge ReplacementPost Filter Replacement