Nortec Industries NH Series installation manual Pre-Installation

Page 7

1.PRE-INSTALLATION

A.ABOUT THIS GUIDE

(1)This guide is intended as a supplement for the NH Series Installation Guide. The NH Series Installation guide is included with all NH Series humidifiers and contains information on installation, operation, and maintenance that applies to both indoor and outdoor models. This guide contains supplementary information that pertains specifically to the NH Series Outdoor humidifiers.

(2)For information on the installation of controls, interior piping, interior wiring, distribution systems please refer to the NH Series Installation Guide.

(3)The operation and control of the NH Outdoor Series is identical to the indoor series. Please refer to the NH Series Installation guide for information on operating your humidifier.

(4)The maintenance items described in this guide are specific to the outdoor model and must be performed IN ADDITION to the regular maintenance that an indoor model would require. Please refer to the NH Series Installation guide for other regular maintenance items.

B.RECEIVING & UNPACKING EQUIPMENT

(1)Check packing slip to ensure ALL material has been delivered.

(2)All material shortages are to be reported to NORTEC within 48 hours from receipt of goods. NORTEC assumes no responsibility for any material shortages beyond this period.

(3)Inspect shipping boxes for damage and note damages on shipping waybill accordingly.

(4)After unpacking, inspect equipment for damage and if damage is found, notify the shipper promptly.

(5)All NORTEC products are shipped on an FOB factory basis. Any and all damage, breakage or loss claims are to be made directly to the shipping company.

2.PACKAGING

A.GENERAL

(1)The equipment packaging is standardized in that each box in the shipment will always have the same contents. The following paragraphs identify the contents of each box.

B.HUMIDIFIER SKID

(1)Typically the NH Series Outdoor Humidifier ships on a skid (shown in Figure 1). Controls and accessories are shipped separately in a box. The contents of the box will be listed on the outside of the box.

C.DISTRIBUTOR BOX

(1)Depending on the equipment ordered any of the following distributor box configurations may be received:

10-00

Page 2 2008-10-01

Image 7
Contents SeriesTM Outdoor Proprietary Notice Liability Notice Table of Contents List of Figures This page Intentionally Left Blank Introduction PRE-INSTALLATION Accessories BOX Humidifier Moving and Handling the Humidifier Equipment VerificationThis page Itentionally Left Blank Installation Procedures AIR Handler Mounting Humidifier InstallationWall Mounting Curb Mounting10-10 Front View Back View Typical Air Handling Unit Installation Typical Wall Mount Installation Water Supply Line Electrical Installation10-10 Normally Open / Normally Closed Valve Arrangement Way Valve Arrangement Auxiliary Drains Drain LineSteam Lines Important Information Freeze Protection System Standard Servicing Nhrs with Scale Management System Cleaning Dust and Pollen DepositsRestarting After Freezing Operation Additional MaintenanceWeather Data Weather Design Data 10-10 10-10 Table Source Ashrae Technical Nhrs Outdoor Exploded View Nhtc Outdoor Exploded View This page Intentionally Left Blank Wiring Diagrams Wiring Diagram Nhtc Outdoor Wiring Diagram Nhrs Outdoor Single Wiring diagram Nhrs Outdoor Double This page Intentionally Left Blank Warranty Cylinder Replacement Date MM/DD/YYYY

NH Series specifications

Nortec Industries has made a notable impact in the field of HVAC solutions with its NH Series, a cutting-edge line of commercial and industrial dehumidifiers. Known for their robust performance and high efficiency, these units are ideal for a wide variety of applications, including warehouses, manufacturing facilities, and other large spaces where humidity control is crucial.

One of the standout features of the NH Series is its advanced refrigerant technology, which allows for exceptional energy efficiency while maintaining effective moisture removal. This is particularly beneficial in environments where excessive humidity can lead to operational issues, mold growth, and deterioration of materials. By implementing state-of-the-art compressors and fan technologies, Nortec Industries ensures that these units consume less energy compared to traditional dehumidifiers, resulting in cost savings for operators.

Another key characteristic of the NH Series is its modular design. This allows users to customize their setup according to specific needs, whether that involves scaling the system up or down depending on space requirements. The units can be easily integrated into existing HVAC systems, providing seamless operation without the need for substantial modifications. This flexibility makes them a popular choice for facility managers aiming to optimize their humidity control strategies.

The NH Series also boasts a user-friendly interface, equipped with digital controls that enable operators to monitor and adjust settings with ease. This feature enhances the operational efficiency of the units, as real-time data can be accessed to ensure optimal performance. Additionally, the inclusion of advanced sensors enhances the system's responsiveness, allowing for automatic adjustments based on current environmental conditions.

Built with durability in mind, the NH Series is constructed from high-quality materials capable of withstanding demanding environments. This ensures longevity and reduces the overall maintenance needs of the system. Nortec Industries also provides comprehensive support and warranty options, reinforcing its commitment to customer satisfaction and reliable performance.

In conclusion, the NH Series by Nortec Industries represents a perfect blend of technology, efficiency, and user-focused design. With its advanced refrigerant technology, modular capability, user-friendly controls, and durable construction, it stands as a premier choice for effective humidity management in a range of commercial and industrial settings. The NH Series not only addresses the challenges of moisture control but also promotes a cost-effective and sustainable approach for businesses looking to enhance their operational efficiency.