D. HUMIDIFIER MANDATORY START-UP CHECKLIST AND QUICK REFERENCE

Unit Serial #: _________________No. of humidifiers: _______

Tag: _______________

Unit type: ___________________Voltage: _____V/___ph

Steam output: ____lbs/hr

Customer/Job: ______________ Address: ______________________________________

Inspected by: ________________Date of inspection: ____/____/____

1.PRELIMINARY:

Pre-start-up checklist completed? yes ___ no ___

If no, return to Pre-Start-up Checklist before going on with start-up procedure.

2.START-UP PROCEDURE:

The prerequisites for getting power and water into the steam cylinder are as follows:

check that main breaker is on and power is at the unit.

check that main water shut-off valve is open.

on/off/drain switch must be switched on.

control circuit 1-2 must be made.

modulation humidistat, if present, must be calling.

door interlock switch must be made (interlock switch can be pulled out to operate unit). The unit will undergo a self-test to ensure integrity of all the components:

NHTC Start-Up Unit Cylinder

Reading Cylinder Data

Inlet Valve

Drain Valve

Heat Controller

Pump

Bleed Valve

Steam Relay

Service Relay

Error Relay

Operation Relay

It will then start filling the cylinder and begins normal operation. Most water does not contain enough conductivity for full boil on initial start-up. Units will need to concentrate the water over a time period (hours to days).

Remarks:

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

10-50

Page 73 2008-08-28

Image 80
Contents SeriesTM 2522381-C2008-08-28 Revision Number Date Date Put ManualTable of Contents Warranty List of Figures List of Tables 2008-08-28 Introduction Nhtc PRE-INSTALLATION PackagingHumidifier Box Preinstallation Equipment Verification Typical Nhtc Installation Sheet 1 Typical Nhtc Installation Sheet 2 This page Intentionally Left Blank Installation Humidifier Installation LocationMounting with Keyholes Mounting with Wall BracketSteam Runs and Condensate Returns Water Supply LineDrain Line Drain Water from Humidifier can be Very HOT Clearances and Operating Conditions Drain Water and Supply Connection 30+ Copper Tube Inch MED-L Tubing 1.125 inch OD 10-10 10-10 Nominal Tube Standard 90degree Standard 45 degree Diameter Side Outlet TeeSteam Outlet Steam InletPrimary Voltage Supply Wiring Primary Voltage Supply Wiring to Humidifier Control WiringDemand Signal Controls Installation ElectricalOn/Off Control Guidelines and Low Voltage Terminal Strip Nortec Control Guidelines and Wiring Optional Optional Outdoor Temperature Reset Function Setpoint Versus Outdoor TemperatureNetworking Nhtc Humidity Transducer Signal InstallationNortec Online Installation Nortec Humidity Transducer Guidelines and Wiring Optional Networking NHTCs Optional Nortec OnLine Installation Guidelines Optional Operation Nhtc Nhtc ComponentsHumidifier START-UP Basic Steam Production MethodNHTC/NHPC Components Item Number Component Name DescriptionIf loose or frayed Humidifier Start-Up Basic Steam Production Method Software Flow Chart with Definitions Software Initial SELF-TESTSelf-Test Messages SELF-HELPSoftware Flow Chart Sheet 1 Software Flow Chart Sheet 2 Software Flow Chart Sheet 3 Software Flow Chart Sheet 4 Software Flow Chart Sheet 5 Software Flow Chart Sheet 6 Software Flow Chart Sheet 7 Signal Light Status System Messages and LightsDouble Unit Operation Yellow Green RedStatus Messages with LED State Nhtc Display Message LED state System ActionSymptom Diagnosed Probable Cause Corrective Action SAM-e Operation Steam DistributionSteam Distributor Operation Blower Pack Operation and Adjustments Digital Transducer Operation Controls and Remote Communication OptionalDigital Control Operation Nortec Links 2 Operation Nortec Online OperationThis page Intentionally Left Blank Maintenance Procedures Extended SHUT-DOWN When to Replace the Steam CylinderNH Electrode Steam Humidifiers Components of the Steam Cylinder Cylinder ComponentsHOW to Remove the Steam Cylinder Cylinder Removal ProcedureMandatory Cleaning of the Drain Valve Drain Valve MaintenanceHOW to Install the Replacement Cylinder Cylinder Replacement ProcedureTroubleshooting Starting Point Troubleshooting NH Electrode Steam HumidifiersPreparation Troubleshooting Symptoms System What to Check WhyTroubleshooting Distributors Ensuring a Demand SignalProcedure Check Why and HowBlower Packs Troubleshooting Digital ON/OFF Humidistat Sensor CalibrationNH System Messages REDProbable Cause Corrective Action E17 Req off current Contactor is open? W27 Safety loop instability Verify that the RH setpoint is less than the RH high limit Term Definition 10V Digital Humidistat Sensor CalibrationTerm Definitions Technical Humidifier Control Information Wiring and TerminalsController and Sensor Specifications NH Wiring NHTC/NHPC Double Unit Wiring DiagramNHTC/NHPC Wiring Diagram Check Lists PRE-NORTEC Online Start UP Checklist WiringPRE-NORTEC Links START-UP Checklist Humidifier Mandatory PRE-START UP Checklist WiringPower Water QualityHumidifier Mandatory START-UP Checklist and Quick Reference START-UP ProcedurePreliminary RemarksCylinder Replacement Procedure Periodic Maintenance Checklist and Quick Reference page 1When to Replace the Cylinder Periodic Maintenance Checklist and Quick Reference page 2 Extended ShutdownSpare Parts and Exploded Views ASD, BSD, CSD DistributorNH Series Humidifier Spare Parts NHTC/NHPC Plumbing Compartment Exploded View and Spare PartsNHTC/NHPC Plumbing Part List Model10-50Page 79 NHTC/NHPC Plumbing Part List Fillcup Extension KIT NHTC/NHPC10-50 10-50Page 81 NHTC/NHPC Electrical Parts List Three Phase This page Intentionally Left Blank Warranty Cylinder Replacement Date MM/DD/YYYY Walter Meier Climate USA Inc

NH Series specifications

The Nortec NH Series stands as a remarkable line of heating and cooling equipment designed specifically for commercial and industrial applications. Renowned for its efficiency, reliability, and innovation, the NH Series is engineered to meet the demanding needs of various environments, including hospitals, educational institutions, and office buildings.

One of the standout features of the Nortec NH Series is its modular design. This flexibility allows for easy integration into existing systems, making it an ideal choice for both new installations and upgrades. The modular setup not only enhances space efficiency but also allows users to scale the system according to their specific requirements. This adaptability is essential for facilities looking to optimize their HVAC systems without extensive renovations.

The NH Series incorporates advanced technologies that set it apart in the market. It employs high-efficiency heat exchangers made from durable materials that provide exceptional thermal performance. These heat exchangers facilitate rapid heat transfer while maintaining energy efficiency, lowering operational costs. Additionally, the unit features variable-speed fans that adjust airflow according to real-time demands, contributing to quieter operation and further energy savings.

Another noteworthy characteristic of the NH Series is its intelligent control system. The integrated controls offer user-friendly interfaces and compatibility with building management systems. This enables operators to monitor and adjust settings remotely, enhancing operational efficiency and ensuring optimal indoor climate conditions.

Furthermore, the Nortec NH Series is designed with sustainability in mind. It complies with stringent environmental regulations and utilizes eco-friendly refrigerants, reducing the overall carbon footprint of the facility. This commitment to sustainability resonates with businesses looking to enhance their green credentials while maintaining a comfortable environment.

In summary, the Nortec NH Series exemplifies innovation in HVAC technology, combining modular design, high-efficiency heat exchangers, variable-speed fans, intelligent controls, and sustainable practices. These features make it a top choice for professionals seeking reliable and efficient heating and cooling solutions for a variety of commercial applications. With the Nortec NH Series, users can achieve significant energy savings, enhanced comfort, and a positive impact on the environment.