Lucent Technologies 6 manual 3820, 3830

Page 57

3800 Series Modem Installation

The recommended order of execution of AT commands if executed one at a time is as listed above due to the loss of command echo towards the bottom of the list. Alternatively, the single command “AT&F0 &D2 &S1 V2 X7 Y0 %C0 S41=3 S2=128 E0 &W0” can be executed.

When the 7400A data module is optioned for more than one speed it is necessary to set the modems’ ExtendResltCode to “Use_DTE_Rate.” One would suspect that the modems’ DialTone Detect and BusyTone could be “Disable” in a modem pooling application, but using the AT command “X7” to set the ExtendResltCode to “Use_DTE_Rate” automatically enables DialTone and BusyTone Detect. That is why they are optioned as enabled here (as well as being the factory default).

To run at speeds other than 19200 bps the DTE Rate and Dial Line Rate should be changed. Note that the AT prefix determines the asynchronous DTE Rate (as well as the Number of Data Bits, Parity, and Number of Stop Bits). The corre- sponding LCD command sequence for DTE Rate is under Configure/Edit/DTE Interface. The AT command for Dial Line Rate is “s41=r,” where r is the new rate. The corresponding LCD command sequence for Dial Line Rate is under Config- ure/Edit/Dial Line. The 3800 series modems have large buffers and perform speed conversions well.

Administrators may want to disable the AT Escape Char option. This prevents users from changing straps. This option is disabled by setting AT Escape Char to 128. The default value is 43 (i.e., a + sign).

3820

The 3820s should be installed in permissive mode. Insert a 4-conductor modular plug into the jack labeled DIAL/LEASED (3820). Option settings with equivalent AT command and Diagnostic Control Panel LCD command sequences are as pro- vided for 3810 above.

3830

The command “at i1” displays the firmware revision number and “at i19” displays the revision number. The 3830s should be installed by inserting a 4-conductor modular plug into the jack labeled LINE. Option settings by AT commands are as provided for the 3810 above. To verify the modem settings on a 3830 since the modem does not have an LCD display panel, use the following commands:

nAT&V0 to view active (operating) configuration options AT&V1 to view active (saved) configuration options

Issue 1 CRCS R6.0 April 1999 53

Image 57
Contents Crcs Release Copyright 1999 Lucent Technologies Inc All Rights Reserved Contents Contents Installation Overview Single-User CRCS/OpCenter OpCenterSP InstallationUpgrading a Single-User System Upgrading from a Previous ReleasePage MCU Link Administration window SoftwarenRequirements Pre-Installation RequirementsRemote Configurations Login and PasswordsFax Option Microsoft Windows Control Panel Settings Configuring the PCDisplay PropertiesnWindow Local Connection to MCU Connecting the PC to the MCURemote Connection to MCU Connection ProcedureRemote Crcs Connection to MCU Modem Pooling Click on Connect Using and select Direct to COM1 Checking the Modem SettingsConnection Description Window Page Loading the CRCS/OpCenter Software CRCS/OpCenter Software InstallationCrcs Setup-Select Components Crcs Setup-Destination Location Crcs Setup-Copying Files Logging In to Crcs Testing CrcsSelect Time Zone Template from the View menu Setting the Time ZoneAdding the MCU Crcs Setup-Adding a Time ZoneEstablishing the Communications Link Crcs Database Setup-Run Link AdministrationMCU Link Administration Window COM Port Tab Uploading MCU Options Running the MCU Extension Utility ProgramAdding an Endpoint Add Endpoint Window Add Conference Template Window Adding a Conference TemplateAdding a Person Adding a CompanyAdd Person Window Adding a SiteAdd Site Window General Tab Adding a Test Conference Editing DefaultsTesting OpCenter-MCU Status Board Testing OpCenterFaxmodem Installation WindowsWindows NT Select the Install Winfax PRO option Select Install NOW Installing WinFax PROSetting Up WinFax PRO WinFax PRO Setup-Dialing Preferences WinFax PRO Setup-CSID Saving Faxes with WinFax Log Files Setting Up Reminder FaxesLoading OpCenterSP Software OpCenterSP InstallationEntering the Location of the Crcs CD-ROM OpCenterSP Setup-Choose Destination Location OpCenterSP Setup-Copying Files Testing OpCenterSP Testing OpCenterSP-MCU Status Board Appendix a Modem Pooling Administering Modem Pool GroupsDisplay Modem-Pool Screen Add Modem-Pool Screen Port Assignments Series Modem Installation 3810Series Modem Installation ATE ATT ATP Series Modem Installation ATM 3830 38207400A Data Module Installation

6 specifications

Lucent Technologies 6 (Lucent 6) is a groundbreaking telecommunications platform developed by Lucent Technologies, a leader in the field of networking and communication solutions. This innovative system is designed to enhance various aspects of modern telecommunication, combining cutting-edge technology with user-friendly features.

One of the main features of Lucent 6 is its robust architecture, which supports a wide range of communication services, including voice, data, and multimedia. This flexibility allows organizations to streamline their operations and reduce costs while maintaining high-quality service delivery. The platform employs advanced signaling protocols and transport technologies, enabling seamless integration with existing telecommunication networks.

Lucent 6 incorporates several key technologies that contribute to its superior performance. One such technology is Voice over Internet Protocol (VoIP), which enables high-quality voice communication over Internet Protocol (IP) networks. This not only reduces the dependency on traditional circuit-switched networks but also offers enhanced functionality, such as call screening and advanced voicemail capabilities.

Another critical technology within the Lucent 6 platform is the Intelligent Networking (IN) capability, which supports enhanced call features and services. This allows operators to provide customized services to their customers, leveraging real-time data and intelligent routing mechanisms to optimize network performance. The IN capabilities ensure that users have access to advanced features like call forwarding, conferencing, and dynamic number identification.

Security is a paramount consideration in telecommunications today, and Lucent 6 addresses this through its advanced encryption protocols and secure access measures. These security features protect sensitive data and ensure that communication remains confidential, safeguarding against unauthorized access and potential cyber threats.

Additionally, Lucent 6 is designed with scalability in mind, allowing organizations to expand their services easily as their needs grow. The modular architecture supports various hardware and software configurations, making it adaptable to changing requirements and future technological advancements.

In conclusion, Lucent Technologies 6 stands out in the landscape of telecommunications for its comprehensive set of features, including VoIP, Intelligent Networking, and robust security measures. Its scalable architecture and integration capabilities make it an attractive choice for organizations seeking to enhance their communication services while preparing for future technological developments. As a result, Lucent 6 continues to be a significant player in the evolution of modern telecommunications.